当前位置:网站首页>The fire door monitoring system carries out 24-hour real-time automatic inspection on the status of the fire door
The fire door monitoring system carries out 24-hour real-time automatic inspection on the status of the fire door
2022-06-09 08:47:00 【acrelwc】
Encore Wang Chong
【 Abstract 】: The fire door monitoring system is mainly aimed at the normally open... On the evacuation passage 、 Conduct real-time detection for normally closed fire doors , When the fire door opens or closes abnormally , The system will send out audible and visual alarm signals , Remind the maintenance personnel to handle the fault , When a fire breaks out on site , It can also control the normally open fire door to close , Prevent the spread of fire and smoke , Provide valuable time for people and evacuation . This system product is applicable to residence 、 School 、 The hospital 、 Exhibition Hall 、 Hotels and other places .
【 key word 】: Fire door monitoring system ; Normally open fire door ; Normally closed fire door ; residential
0 . Preface
With the economy 、 The rapid development of science and technology , The density of people in cities is increasing , In case of fire , Quickly isolate the fire source , Reasonably control the scope of fire , It can create good conditions for fire fighting and personnel evacuation . therefore , Fireproof partitions such as fireproof doors are widely used in the fire protection design of construction projects , But its design is unreasonable 、 Improper model selection 、 Inadequate monitoring and other reasons , So that the fireproof door can not give full play to its isolation function . Therefore, real-time monitoring and control of the working state of the fire door , It is an important measure to prevent the spread of fire and smoke , Therefore, the fire door monitoring system came into being .
Fire door monitoring system is a new product in the field of fire safety , It integrates industrial computer technology 、 Communications 、 Anti electromagnetic interference 、 Digital sensor technology and industrial fieldbus control technology in one of the intelligent system , The working state of the fire door can be 24 Hour real-time automatic patrol inspection , Give alarm prompt to the fire door in abnormal state . In case of fire , The monitoring system automatically closes the fire door , Win valuable time for fire rescue and personnel evacuation .
1. Project introduction
The project is a residential project , from A2-1 Land and A3-1 The composition of the plot , See Table 1 for the distribution of buildings .
among ,A2-1 The upper part of the plot is 5 A first-class high-rise residence (1-1# floor 23 layer 、1-2# floor 25 layer 、1-3# floor 25 layer 、1-4# floor 26 layer 、1-5# floor 26 layer ) and 2 A multi-storey public building (1-S1# The building is 3 Layer business ,1-S2# The building is 2 Transformation and distribution room on the first floor ); The basement 1 layer , Pump room is set locally 、 Cable TV room and other equipment rooms , The rest serve as garages , Small motor vehicles can be parked 565 car , Non-Motor Vehicle 838 car , Belong to Ⅰ Automobile like garage . The underground construction area is about 12782.63m2 , The ground floor area is about 51909.74m2, Gross floor area 64692.37m2, The total height of the building is as high as 76.05m, It belongs to class II residential land .
A3-1 The upper part of the plot is 5 A first-class high-rise residence (2-1# floor 21 layer 、2-2# floor 22 layer 、2-3# floor 22 layer 、2-4# floor 23 layer 、2-5# floor 26 layer ) and 1 A multi-storey public building (2-S1# The building is 1 Layer business 、2 Transformation and distribution room on the first floor ); The basement 1 layer , Pump room is set locally 、 Cable TV room and other equipment rooms , The rest serve as garages ( Peace and war ), Small motor vehicles can be parked 509 car , Non-Motor Vehicle 710 car , Belong to Ⅰ Automobile like garage . The underground construction area is about 12486.82m2 , The ground floor area is about 46739.78m2, Gross floor area 59226.6m2, The total height of the building is about 76.05m, It belongs to class II residential land .
Table 1 : Buildings are distributed

2. Site requirements and product solutions
2.1 Fire door monitoring module requirements
2.1.1 Fire door monitoring module site requirements
According to the needs of customers , In the front room of the elevator where people often pass , Normally open fire doors shall be provided ; Normally closed fire doors are generally set at the stair entrances ;
2.1.2 Fire door monitoring module product scheme
Product application matching scheme ; See the table below 3.

surface 3: List of fire door monitoring module selection
2.2.1 On site host and extension requirements 2.2 Fire door monitoring host and extension requirements and solutions
According to the table 1 And graph 1 The needs of , We need to be in A2-1 Land and A3-1 A set of fire door monitoring host is set in each plot , Then set up a set of regional extensions in each building for networking .
2.2.2 Host and extension scheme

Fire door monitoring host

Area extension
See the following table for parameters of fire door monitor and area unit 4 And table 5
surface 4: Parameters of fire door monitor

surface 5: Parameters of the area extension

2.3 System requirements and solutions
2.3.1 System requirements and solutions
Precautions for system networking
① Communications : host - extension :CAN Bus ,500 rice , Each circuit ≤32 platform
host - modular : Two bus , 500 rice , Each circuit ≤64 platform
② Bus condition :CAN Bus :NH-RVSP2*1.5mm²
Two bus :NH-RVSP2*2.5mm²
③ Wiring way :CAN Bus : Hand in hand
Two bus : Hand in hand 、 Star type 、 Tree shape Equal connection method
2.3.2 software interface
contain “ land ” Button 、“ Interface title ”、“ Function list ”、“ System status bar ” Four-part composition , You can quickly query the current monitoring status , It can also be used for staff login .
User login interface

After entering the correct user name and password , The system status bar will directly jump to the current user's operation interface , It can display the list of currently logged in users and functions .
Permission management interface
This interface has three operation levels , New users of lower level can be added to those with higher operation permission level .
Condition monitoring interface
This interface intuitively displays the fire door icon in a graphical way , The system will display the details of the fire door .
4. Conclusion
With the development of China's economy and society , The security problem has attracted more and more attention , People gradually realize that the fire door monitoring system plays a very important role in the occurrence of fire . therefore , This system has a broad market prospect , And is becoming a sunrise industry in the field of fire protection , Ankerui electric focuses on building products of various fire security systems , On the premise of meeting the requirements of national industrial standards , Provide intelligent services for all kinds of buildings 、 reasonable 、 Energy saving 、 Cheap fire-fighting solutions and products , For fire prevention and disaster reduction 、 Make a contribution to ensuring the safety of people's lives and property !
reference
[1]. Ankerui enterprise microgrid design and Application Manual .2020.06 edition
[2].GB50116-2013 Code for design of automatic fire alarm system [S].
[3].GB50016-2014 Code for fire protection design of buildings [S].
[4].GB29364-2012《 Fire door monitor 》
边栏推荐
猜你喜欢

【程序人生】互联网岗位分工;互联网开发流程;职责分工

10种提问型爆文标题句式 直接套用

SQL: people flow in the gymnasium (common solution for continuous day cases)

SQL:锦标赛优胜者

Modifier le tableau des activités de marché

远程预付费管理系统帮助物业解决收费难统计难问题

Mock interview plan; Campus simulated interview plan; Job search simulation interview contest plan; Planning book of simulated job hunting competition of School of economics and management; College st

SQL:体育馆的人流量(连续日期案例通用解决方案)

编辑器说明-备用

安科瑞配电室综合监控系统实现配电室内环境的在线监测,保障配电室设备的安全运行
随机推荐
Cleaning data ---2022/06/08
JS realizes three-level linkage
华为机试,HJ6质数因子
Configuring the environment for RMAN backups_ Configure backup retention policy
Lambda表达式
SQL: people flow in the gymnasium (common solution for continuous day cases)
Mobile terminal layout of Xiaomi official website
配置RMAN备份的环境_配置备份保留策略(RETENTION POLICY)
I met a big man!
Direct application of 10 kinds of question type explosive text title sentence patterns
Configuring the environment for RMAN backups_ Configure channel
Business judgment logic code if statement
RMAN backup concept_ About backup retention policy
Openinfra summit 2022 𞓜 China cloud data users once again won the super user Award
Introduction to framework: the update expression is invalid. At least one column must be updated
Sql: find duplicate email addresses
SQL: market analysis I
js类的创建和constructor的构造函数的使用
Nodejs uses net module to create TCP server and client
10 useful flutter widgets