Safe operation instructions for oscilloscope probe that must be read by engineers
2022-07-25 18:19:00 【PRBTEK】
The probe is the bridge between the oscilloscope and the measured object , Without this bridge , The oscilloscope cannot read the information of the tested object , Therefore, the oscilloscope probe is also an integral part of the test . that , What problems should we pay attention to when using the oscilloscope probe ? Today, oscilloscope probe experts —— Puke Technology (PRBTEK) Share with you the use of Oscilloscope probe Safety precautions that must be known :

PRBTEK It is suggested that users should read the following safety precautions , Avoid personal injury , Prevent damage to the test equipment or any product connected to the test equipment . To avoid possible losses , Use the test equipment only according to the manufacturer's instructions . remember , All voltages and currents are potentially dangerous , Including personal injury or equipment damage .
One 、 Observe the rated data of all terminals
● To avoid fire or electric shock hazards , Observe all ratings and marks on the product . Before connecting the product , Consult the product manual , For further rating information .
● Do not apply a potential greater than the maximum rating of any terminal .
● Only connect the ground wire of the probe to the ground .
Be careful :
For oscilloscopes specially designed and specified for floating oscilloscope applications ( Such as tech THS700 Series battery powered digital storage oscilloscope ), The second line is the public line , Not ground . under these circumstances , The manufacturer's specification for the maximum voltage that can be connected shall be observed .
● Inspection probe and test equipment instructions , Observe the information of any rating decrease . for example , As the frequency increases , The maximum input voltage rating may decrease .
Two 、 Use the correct grounding procedure
● The probe is indirectly grounded through the ground wire of the oscilloscope power line . To avoid the risk of electric shock , The ground wire must be connected to the ground . Before connecting the input or output terminals of the product , Ensure that the product is properly grounded .
● Do not try to make the power line of any test equipment grounding defects .
● Only connect the probe ground wire to the ground .
● Separate the oscilloscope from a ground that is not specifically designed and designated for such operations , Or connect the ground wire to any other item besides the grounding , It may cause the connector of oscilloscope and probe 、 Dangerous voltage appears on control equipment or other surfaces .
Be careful :
This applies to most oscilloscopes , But some oscilloscopes are designed to work in floating applications , Such as tech THS700 Series battery powered digital storage oscilloscope .
3、 ... and 、 Connect and disconnect the probe correctly
● First connect the probe to the oscilloscope . Before connecting the probe to any test point , The probe should be properly grounded .
The probe ground wire should only be connected to ground _ On .
● When disconnecting the probe from the circuit under test , First unplug the probe tip from the circuit , Then disconnect the ground wire .
Except probe tip and probe connector center wire , All metals that can be touched on the probe ( Including grounding clip ) Must be connected to the connector housing .
Four 、 Avoid exposed circuits
● Avoid touching exposed circuits or devices with hands or any other part of the body .
● The connection between the probe tip and the ground clamp must be Ensure that it will not accidentally touch or touch other parts of the circuit under test .
● Avoid RF Solidification
● In existence RF At high power , Resonance and reactance effects may convert small voltages into potentially harmful or dangerous voltages .
● If necessary, it exists RF Use the probe in areas where there is danger of fusion , Turn off the power of the signal source , Then connect or disconnect the probe lead . When the circuit is active , Do not handle input leads .
● Do not use measuring equipment without a protective cover
● When removing any protective cover or protective housing , Oscilloscopes and probes should no longer be used . Remove the protective cover 、 Shell 、 The wires or components exposed by the probe body or connector shell may have dangerous voltage .
5、 ... and 、 Do not use measuring equipment in a humid environment
● To avoid electric shock or damage to the equipment , Do not use measuring equipment in a humid environment .
6、 ... and 、 Do not use measuring equipment in explosive atmosphere
● Using electrical or electronic equipment in explosive atmosphere may lead to explosion . Gasoline in use or storage 、 solvent 、 Ether 、 Propane and other volatile substances , Explosive air may be produced . in addition , Some fine dust or powder suspended in the air may produce explosive air .
7、 ... and 、 Do not use measuring equipment when there may be problems
● If you suspect that there are electronic or physical problems with the oscilloscope or probe , It should be checked by qualified personnel , Can continue to use .
How to maintain the oscilloscope probe ?
● Water vapor on the probe 、 Dust and other impurities will provide a conduction path . To ensure the safety and accuracy of measurement , Keep the probe surface clean and dry .
● Only use the procedures specified in the probe instructions to clean the probe .
Which environments are not suitable for using the probe ?
● Immersing the probe in liquid may provide a conduction path between internal devices , Or damage or corrosion of internal devices or external enclosures and shielding .
● Only use the procedures specified in the probe instructions to clean the probe .
General science and technology PRBTEK Arrangement
边栏推荐
- JZ32 从上往下打印二叉树
- CH582 BLE 5.0 使用 LE Coded 广播和连接
- Oracle导入出错:IMP-00038: 无法转换为环境字符集句柄
- "Digital security" alert NFT's seven Scams
- MySQL optimistic lock
- Which real-time gold trading platform is reliable and safe?
- STM8S003F3 内部flash调试
- Recognized by international authorities! Oceanbase was selected into the Forrester translational data platform report
- 更新|3DCAT实时云渲染 v2.1.2版本全新发布
- Polynomial addition
猜你喜欢

泛域名配置方法

Construction of Huffman tree

Tme2022 campus recruitment background development / operation development / business operation and maintenance / application development written examination (I) a little self analysis of programming q

图的相关操作
SQL optimizer parsing | youth training camp notes

Keil5 "loading PDSC debug description failed for STMicroelectronics stm32hxxxxxxx" solution

How to judge the performance of static code quality analysis tools? These five factors must be considered

Update 3dcat real time cloud rendering V2.1.2 release

One week activity express | in simple terms, issue 8; Meetup Chengdu station registration in progress

Cve-2022-33891 Apache spark shell command injection vulnerability recurrence
随机推荐
tkinter GUI版通信录管理系统
Wu Enda's machine learning programming operation cannot be suspended pause problem solved
STM32F105RBT6 内部flash调试
CircleIndicator组件,使指示器风格更加多样化
ORB_SLAM3复现——上篇
Repair process of bad blocks of primary standby database
How to judge the performance of static code quality analysis tools? These five factors must be considered
GAN的详细介绍及其应用(全面且完整)
结合GHS MULTI使用瑞萨E1仿真器实现对瑞萨RH850单片机的仿真调试
LeetCode 101. 对称二叉树 && 100. 相同的树 && 572. 另一棵树的子树
Polynomial addition
ORB_ Slam3 recurrence - Part I
MySQL 索引优化全攻略
柔性电流探头选型指南
NC68 跳台阶
Stm32f105rbt6 internal flash debugging
MATLAB中join函数使用
MySQL lost the previous 0 after the decimal number type select
程序的编译
Talking about Devops monitoring, how does the team choose monitoring tools?