name : Large capacity two position modular relay
model :DLS-44/4-4 Two position relay
Rated voltage :48,110,220VDC/110,220,380VAC
Contact capacity :250V10A
Coil power :3.5WDC/15WAC
Action time :30/25MS
DLS-42
Series models :
DLS-41/10-2 Two position relay ;
DLS-41/9-3 Two position relay ;
DLS-41/8-4 Two position relay ;
DLS-41/6-6 Two position relay ;
DLS-42/9-1 Two position relay ;
DLS-42/8-2 Two position relay ;
DLS-42/7-3 Two position relay ;
DLS-42/6-4 Two position relay ;
DLS-42/5-5 Two position relay ;
DLS-43/9-1 Two position relay ;
DLS-43/8-2 Two position relay ;
DLS-43/7-3 Two position relay ;
DLS-43/6-4 Two position relay ;
DLS-43/5-5 Two position relay ;
DLS-44/8 Two position relay ;
DLS-44/7-1 Two position relay ;
DLS-44/6-2 Two position relay ;
DLS-44/5-3 Two position relay ;
One 、 purpose
DLS-40 Series double position relays are used in various protection and automatic control devices , To achieve the locking effect . among DLS-41、42 Type is used for straight
Flow loop ,DLS-43、44 Type A is used for AC circuit .DLS-41、43 The coil of does not string contacts ,DLS-42、43 Coil string contacts of
Two 、 Main technical parameters
Rated voltage :DC 220V、110V、48V;AC 220V、110V.
Rated current :0.25A、0.5A、1A、2A、4A、6A.
Action voltage : Not greater than the rated voltage 70%.
Action current : Not greater than rated current .
Power consumption : DC is not greater than 7W; Communication is not greater than 15VA.
Medium strength
The conductive circuits of the product are connected together between exposed non live metal parts or shells , And between the coil circuit and the contact circuit , Should be able to bear
suffer 2kV( Valid values ),50Hz Of
AC test voltage duration 1min Test of , Without insulation breakdown or flashover .
DLS-42/6-4 DC110V Two position relay
Ordering instructions
The relay model and specification must be indicated when ordering Structural form code Wiring mode before or after the board .
“ Two coils , Each coil is connected with a contact in series , One normally open and one normally closed , The force exerted by a magnet when there is no electricity , Fix the armature in the initial position , When the coil of normally closed contact station is powered on , When the coil is energized, the armature moves , After the action, the magnet will fix it at the position after the action , At the same time, the armature acts to make the series connection point of the two coils Set switch , The original normally closed contact is open , De energize the coil , The original normally open contact is closed , At the corresponding coil Ready to power on . Because it is held mechanically by a magnet , Therefore, after the control power supply disappears, its position will remain in the control position The state before the power supply disappears , It will not return to the original state after power loss like the electric hold relay .”
Shanghai Joseph relay business department
边栏推荐
- ESP8266 RC522
- The girlfriend said: if you want to understand the three MySQL logs, I will let you heiheihei!
- 初识 Flutter 的绘图组件 — CustomPaint
- mustache语法
- [daily record] - bug encountered in BigDecimal division operation
- Unhandled Exception: MissingPluginException(No implementation found for method launch on channel)
- 2022就要过去一半了,挣钱好难
- ArrayList analysis 1-cycle, capacity expansion, version
- NE555 waveform generator handle tutorial NE555 internal structure (I)
- HDU 2488 A Knight's Journey(DFS)
猜你喜欢

Oracle table creation and management

Gavin's insight on the transformer live broadcast course - rasa project's actual banking financial BOT Intelligent Business Dialogue robot system startup, language understanding, dialogue decision-mak

Training discipline principle of robot programming

给按钮的边框和文字设置不同的背景色

High quality pump SolidWorks model material recommended, not to be missed

fluttertoast

C#生成putty格式的ppk文件(支持passphrase)

Q弹松软的大号吐司,带来更舒服的睡眠

機器人編程的培訓學科類原理

Metauniverse and virtual reality (II)
随机推荐
Gavin's insight on the transformer live broadcast course - rasa project's actual banking financial BOT Intelligent Business Dialogue robot system startup, language understanding, dialogue decision-mak
关于VCTK数据集
运动与健康
The longest selling mobile phone in China has been selling well since its launch, crushing iphone12
解读创客教育所蕴含的科技素养
DLS-20型双位置继电器 220VDC
Oracle table creation and management
Practical shell knowledge
For the first time in more than 20 years! CVPR best student thesis awarded to Chinese college students!
Get to know the drawing component of flutter - custompaint
人穷志不短,穷学生也能玩转树莓派
剑指 Offer 19. 正则表达式匹配
Listview in flutter application development
Get screen height
pytorch编程知识(2)
ESP8266 RC522
Metauniverse and virtual reality (II)
[original] PLSQL index sorting optimization
剑指 Offer 18. 删除链表的节点
Exercise and health