The 100% question bank provides Building eight ( Standard Officer ) Examination questions 、 Building eight ( Standard Officer ) The real exam question 、 Building eight ( Standard Officer ) Certificate examination question bank, etc , Provide online questions and brush questions , Online mock exam , Help you pass the exam easily .

25. The standard number is GB/T50214-2013 yes ().
A. Technical specification for composite steel formwork
B. Technical code for application of geosynthetics
C. Technical specification for tube well
D. Code for construction of residential decoration
answer :A
analysis : The standard number is GB/T50214-2013 It is the technical specification of composite steel formwork .
26. according to 《 Technical code for safety of temporary electricity on construction site 》JGJ46-2005, When there are overhead lines around the project under construction , When the voltage level of the external power line is 1~10kV when , Projects under construction ( Including scaffold ) The minimum safe operation distance between the periphery of the and the sideline of the overhead line is ().
A.10m
B.5m
C.6m
D.4m
answer :C
analysis : according to 《 Technical code for safety of temporary electricity on construction site 》JGJ46-2005, When there are overhead lines around the project under construction , When the voltage level of the external power line is 1~10kV when , Projects under construction ( Including scaffold ) The minimum safe operation distance between the periphery of the and the sideline of the overhead line is 6m.
27. according to 《 Code for acceptance of construction quality of concrete structures 》GB50204-2015, During reinforcement installation , Grade of stressed reinforcement 、() And the quantity must meet the design requirements .
A. Location
B. weight
C. Number of roots
D. specifications
answer :D
analysis : according to 《 Code for acceptance of construction quality of concrete structures 》GB50204-2015, During reinforcement installation , Grade of stressed reinforcement 、 The specification and quantity must meet the design requirements .

28. according to 《 Construction elevator installation 、 Use 、 Safety technical regulations for disassembly 》JGJ215-2010, Do not use () As the control switch for stopping operation .
A. Leakage protector
B. Travel limit switch
C. sensor
D. Luffing limiter
answer :B
analysis : according to 《 Construction elevator installation 、 Use 、 Safety technical regulations for disassembly 》JGJ215-2010, It is forbidden to use the travel limit switch as the control switch for stopping operation .
29. according to 《 Unified standard for construction quality acceptance of construction engineering 》GB50300-2013, After repair or reinforcement, it still cannot meet () Or divisional works and unit works of important functions , Acceptance is strictly prohibited .
A. Size
B. elevation
C. Security
D. weight
answer :C
analysis : according to 《 Unified standard for construction quality acceptance of construction engineering 》GB50300-2013, Divisional works and unit works that cannot meet the safety or important use functions after repair or reinforcement , Acceptance is strictly prohibited .
30. according to 《 Safety technical code for fastener type steel pipe scaffold in building construction 》JGJ130-2011, When the scaffold pole foundation is not at the same height , Must be () Extend two spans and fix with the vertical pole , The height difference should not be greater than 1m.
A. Add fasteners
B. In addition, add longitudinal sweeping rod
C. The lower longitudinal sweeping rod goes up
D. The vertical sweeping rod at the top is lower
answer :D
analysis : according to 《 Safety technical code for fastener type steel pipe scaffold in building construction 》JGJ130-2011, When the scaffold pole foundation is not at the same height , The longitudinal sweeping pole at the top must be extended to the bottom for two spans and fixed with the vertical pole , The height difference should not be greater than 1m.
31.《 Safety technical code for fastener type steel pipe scaffold in building construction 》 comprehensive 、 This paper systematically puts forward the fastener type full hall scaffold 、 Full of support frames ().
A. Safety
B. System
C. Construction method
D. Construction skills
answer :A
analysis :《 Safety technical code for fastener type steel pipe scaffold in building construction 》 comprehensive 、 This paper systematically puts forward the fastener type full hall scaffold 、 The safety of the full support frame .
32. according to 《 Code for construction and quality acceptance of Urban Road Engineering 》CJJ1-2008, Earthwork subgrade construction , When cooperating with personnel to work within the range of machinery , mechanical ().
A. Should leave
B. Work at the same time with cooperating personnel
C. It has to be shut down
D. The operation must be stopped
answer :D
analysis : according to 《 Code for construction and quality acceptance of Urban Road Engineering 》CJJ1-2008, Earthwork subgrade construction , When cooperating with personnel to work within the range of machinery , The machine must stop working .
边栏推荐
- What's special about Huawei's innovative solutions to consolidate the foundation of ERP for small and medium-sized enterprises?
- yuv422转rgb(422sp转420p)
- MySQL master-slave replication data synchronization, summary of common problems
- SSH private key realizes login to remote target server
- Leetcode-919: complete binary tree inserter
- 黑盒(功能)测试基本方法
- An interview question about recover in golang
- Leetcode-79: word search
- Sentinel vs Hystrix 限流对比,到底怎么选?
- Based on pexels image material API, sort out the material resource library
猜你喜欢
![[depth] the new LAAS agreement elephant: the key to revitalizing the development of the defi track](/img/ef/33f93225171e2c3e14b7d090c68196.png)
[depth] the new LAAS agreement elephant: the key to revitalizing the development of the defi track

Achieve accurate positioning based on Tencent map, and realize the attendance punch function of wechat applet

Leetcode-79: word search

【网络教程】IPtables官方教程--学习笔记2

Sentinel vs Hystrix 限流对比,到底怎么选?

When facing complex problems, systematic thinking helps you understand the essence of the problem

Canvas fill gradient
![[FAQ] access the HMS core push service, and the server sends messages. Cause analysis and solutions of common error codes](/img/65/4dd3a521946e753c79d3db1fa0a4f4.png)
[FAQ] access the HMS core push service, and the server sends messages. Cause analysis and solutions of common error codes

Cesium polygon gradient texture (canvas)

As a test, how to understand thread synchronization and asynchrony
随机推荐
matlab----EEGLab查看脑电信号
ONEFLOW V0.8.0 officially released
leetcode-146:LRU 缓存
一道golang中defer和函数结合的面试题
Temperature and humidity environment monitoring system based on stm32
牛客-TOP101-BM37
如何自动生成短链?如何在线批量生成带UTM参数的链接?
字节一面:TCP 和 UDP 可以使用同一个端口吗?
Canvas 填充渐变
Use of C log4net: add file name and line number to the output log content; Repackaged class output file name and line number
DDD go practice
数据库sql语句练习题「建议收藏」
Leetcode-114: expand binary tree into linked list
When facing complex problems, systematic thinking helps you understand the essence of the problem
Achieve accurate positioning based on Tencent map, and realize the attendance punch function of wechat applet
In June 2021, the interview suffered a Waterloo. Is it so convoluted now
CV image flipping, emgucv image rotation "recommended collection"
Vivo official website app full model UI adaptation scheme
Pychart automatically enters the test mode when running the program
The inexplicability of Intel disassembly