当前位置:网站首页>Terminal definition and wiring of bsp3 power monitor (power monitor)
Terminal definition and wiring of bsp3 power monitor (power monitor)
2022-07-25 09:55:00 【Hebei stable control technology】
BSP3 Series power monitor ( single-phase 、 three-phase current 、 voltage 、 Power monitor )

Power monitoring instruments can directly replace conventional power transmitters and measuring instruments . As an advanced intelligence 、 Digital front-end acquisition components , The power meter has been widely used in various control systems ( Such as :SCADA Data acquisition and monitoring control system 、IPDS Intelligent power distribution system and EMS Energy management system ) in . The instrument adopts AC Sampling Technology , It can measure the current in the power grid separately 、 voltage 、 power 、 Parameters such as power factor and electric energy , The magnification can be set through the panel membrane switch , belt RS485 Communications 、 Alarm output 、 Switching value input / Output and other functions .
BSP3 It's an intelligent digital sheet ( many ) Alternating current electric parameter measuring instrument , It can measure the voltage of up to three phases 、 electric current 、 Phase difference 、 power factor 、 Active power 、 Reactive power 、 Apparent power 、 Forward and reverse power 、 Four quadrant power , Automatically accumulate three-phase electricity and save it after power failure .
High speed is adopted 32 position ARM processor , It has strong timeliness 、 Outstanding features of high accuracy . preset 7 Fixed alert types (7 The four commonly used electrical test alarm items are : Underfrequency 、 Overfrequency 、 Undervoltage 、 Overvoltage 、 Over current 、 overload 、 Low power factor .) and 2 User defined alerts , Alarm value and alarm output port can be configured freely . Built in large capacity memory and real-time clock , It can store electric quantity data and alarm data with time tag . The voltage and current of electrical measurement physical quantity adopt isolation transformer , The input and output ports adopt optical couplers , Self contained multiplex ACDC Isolate the power supply , The electric measurement signal input is realized 、 The general input and output ports are completely isolated from the processor , It has strong anti electromagnetic interference and excellent acquisition and control reliability . Built in large capacity super capacitor backup power supply and external power supply monitoring circuit , After the external power supply is interrupted, it can continue to operate autonomously and quickly save important operating parameters . The dot matrix screen makes the single screen display more intuitive and rich , The user operation interface is more humanized . Production of pure domestic components .

Terminal definition
Wiring diagram
Electrical measurement parameters :
Rated frequency : The three phases of this equipment use the same rated frequency parameters .
Power output : How many pulse signals are output per kWh
Filter factor : Collect voltage 、 electric current 、 The depth of filtering the data when the phase and other data , The larger the value, the more stable the data ( But the real-time performance will decline ), Set to 1 Time means no filtering .
A Rated voltage of phase 、 Rated current 、 The coil turns ratio setting of the transformer .
The transformer magnification should be set to the actual transformer parameters , The correct real-time voltage can be obtained only when the transformer magnification is set correctly 、 Current value .
B Phase and C Rated parameters of phase 、 The transformer ratio parameter term is the same as A Exactly the same , It will not be repeated here .
A Phase electric measurement correction parameters .
The first 2 That's ok : Voltage measurement correction parameters --- Voltage addition constant and multiplication constant
The first 3 That's ok : Current measurement correction parameters --- Current addition constant and multiplication constant
The first 4 That's ok : Voltage phase correction plus constant , Current phase correction plus constant
B Phase and C The correction parameter term of phase is the same as A Exactly the same , It will not be repeated here .
边栏推荐
猜你喜欢

Hyperautomation for the enhancement of automation in industries 论文翻译

【数据挖掘】第四章 分类任务(决策树)

如何安装pytorch?—— 一种最简单有效的方法!

从Anaconda到TensorFlow到Jupyter一路踩坑一路填平

Server CUDA toolkit multi version switching

BSP3 电力监控仪(功率监控仪)端子定义和接线

Solve the problem that esp8266 cannot connect mobile phones and computer hotspots

How to import a large amount of data in MATLAB

Minkowskiengine installation

MLX90640 红外热成像传感器测温模块开发笔记(三)
随机推荐
ARMV8 datasheet学习
Coredata storage to do list
A number converted from a decimal integer to another base
单目深度估计自监督模型Featdepth解读(下)——openMMLab框架使用
matlab的find()函数的一些用法(快速查找符合条件的值)
Bracket matching problem
UI prototype resources
一个硬件攻城狮的经济学基础
Exciting method and voltage of vibrating wire sensor by hand-held vibrating wire acquisition instrument
~3 CCF 2022-03-2 travel plan
First knowledge of opencv4.x --- image convolution
[data mining] nearest neighbor and Bayesian classifier
MLX90640 红外热成像传感器测温模块开发笔记(三)
Principle analysis of self supervised depth estimation of fish eye image and interpretation of omnidet core code
Some usages of Matlab's find() function (quickly find qualified values)
AMD EPYC 9664旗舰规格曝光:96核192线程 480MB缓存 3.8GHz频率
Customize the view to realize the background of redeeming lottery tickets [elementary]
MinkowskiEngine 安装
Creation of adjacency table of undirected connected graph output breadth depth traversal
First knowledge of opencv4.x --- image histogram equalization