当前位置:网站首页>What is the intelligent monitoring system of sewage lifting pump station and does it play a big role
What is the intelligent monitoring system of sewage lifting pump station and does it play a big role
2022-07-04 01:47:00 【Juying Internet of things】
Sewage pump station is a municipal facility , Undertake urban drainage 、 Plant water treatment and other functions , Its operation is related to water supply , However, in the management of the pump station, the labor cost of duty shift is high 、 There is time difference in the synchronization of upper and lower level messages 、 Hidden dangers of pump station equipment are not found in time 、 The problems of low management efficiency jointly restrict the efficiency of sewage treatment .
The sewage lifting pump station is located in a low terrain , Gravity cannot make sewage flow into the urban sewage pipe network system , And impurities are often carried in sewage , Problems such as clogging pipes occur from time to time , Therefore, to maintain the operation of sewage lifting pump station , There are many problems to face .
The function of intelligent monitoring system of sewage lifting pump station is mainly reflected in the water level of each pump station 、 Water pump switch alarm 、 Current and voltage of water pump 、 Drainage and security alarm up , The pump station is unattended 、 Remote supervision and centralized management of various pump stations under its jurisdiction , Upgrade the management means of traditional sewage pump stations .

Monitoring platform 、 Control valve 、 Industrial PC 、 Wireless communication and other equipment together constitute the intelligent monitoring system of sewage lifting pump station , Achieve monitoring 、 Inquire about 、 Statistics 、 control 、 Storage 、 analysis 、 Alarm and other functions .
The hardware device consists of data acquisition module 、 Electromagnetic flowmeter 、 Pressure transmitter 、 Liquid level sensor 、 Solenoid valve 、 Measurement and control instrument 、 Data transceiver 、 Lightning arrester 、 Power controller 、 Relay unit 、 Power distribution control cabinet and installation accessories , adopt GPRS/3G/4G And other wireless communication methods , Point to multipoint communication , To achieve the purpose of remote centralized monitoring and control of pumps in each well .
The intelligent monitoring system of sewage lifting pump station realizes unattended , It is necessary to intervene and regulate all links of the pump station , such as :
One 、 According to the setting of the liquid level gauge, the opening quantity of the pump is automatically controlled
Two 、 According to the high 、 Intelligent regulation is set at the low position to start and stop the pump step by step , Set three liquid levels and start the pump station one by one from these three values , And send out the alarm of high liquid level ;
3、 ... and 、 Pump automatic rotation start regulation , Stop running after the pump has been running for a certain period , Rotate another pump to start , The rotation work protects the service life of the pump ;
Four 、 Support manual / Automatically 、 Start the pump remotely ;
Intelligent monitoring system of sewage lifting pump station based on Internet of things , It is not only useful in sewage treatment , At the water supply pump station 、 Replace the heat pump station 、 The purpose of intelligent control can be achieved on irrigation make-up pump stations and other pumps .
边栏推荐
- Query efficiency increased by 10 times! Three optimization schemes to help you solve the deep paging problem of MySQL
- A little understanding of GSLB (global server load balance) technology
- Some other configurations on Huawei's spanning tree
- Jerry's watch information type table [chapter]
- Rearrangement of tag number of cadence OrCAD components and sequence number of schematic page
- QML add gradient animation during state transition
- CLP information - how does the digital transformation of credit business change from star to finger?
- The force deduction method summarizes the single elements in the 540 ordered array
- 51 MCU external interrupt
- Solution to the problem that jsp language cannot be recognized in idea
猜你喜欢

What are the advantages and disadvantages of data center agents?

Huawei cloud micro certification Huawei cloud computing service practice has been stable

JVM performance tuning and practical basic theory - medium

TP5 automatic registration hook mechanism hook extension, with a complete case

A fan summed up so many interview questions for you. There is always one you need!

Make drop-down menu

Conditional test, if, case conditional test statements of shell script

Yyds dry goods inventory it's not easy to say I love you | use the minimum web API to upload files
![Jerry's watch listens to the message notification of the target third-party software and pushes the message to the device [article]](/img/8b/ff062f34d36e1caa9909c8ab431daf.jpg)
Jerry's watch listens to the message notification of the target third-party software and pushes the message to the device [article]

When tidb meets Flink: tidb efficiently enters the lake "new play" | tilaker team interview
随机推荐
Conditional test, if, case conditional test statements of shell script
JVM performance tuning and practical basic theory - medium
Use classname to modify style properties
After listening to the system clear message notification, Jerry informed the device side to delete the message [article]
51 MCU external interrupt
Avoid playing with super high conversion rate in material minefields
Hbuilder link Xiaoyao simulator
Prose article appreciation - the rain in the warm country has never changed into cold, hard and brilliant flowers. Knowledgeable people think he is monotonous, and he thinks he is unlucky, doesn't he?
Why can't it run (unresolved)
Feign implements dynamic URL
MySQL utilise la vue pour signaler les erreurs, Explicit / show ne peut pas être publié; Verrouillage des fichiers privés pour la table sous - jacente
[typora installation package] old typera installation package, free version
File contains vulnerability summary
QML add gradient animation during state transition
Pratique technique | analyse et solution des défaillances en ligne (Partie 1)
Future source code view -juc series
Technical practice online fault analysis and solutions (Part 1)
String & memory function (detailed explanation)
Special copy UML notes
I don't know why it can't run in the project and how to change it