当前位置:网站首页>Xjy-220/43ac220v static signal relay
Xjy-220/43ac220v static signal relay
2022-07-01 01:15:00 【Comprehensive operation of Shanghai Joseph Electric Appliance C】


brand :JOSEF Joseph
name : Signal relay
model :XJY-220
Rated voltage : communication :12380VAC; Direct :12220VDC
Contact capacity :250V5A
Power consumption : The voltage of the coil shall not be greater than 6W; The current coil shall not be greater than 1.5W
XJ Series signal relay ;XJY-220 Signal relay ;
XJY-110 Signal relay ;XJY-48 Signal relay ;
XJY-24 Signal relay ;XJY-12 Signal relay ;
XJL-001 Signal relay ;XJL-0015 Signal relay ;
XJL-002 Signal relay ;XJL-0025 Signal relay ;
XJL-005 Signal relay ;XJL-0075 Signal relay ;
XJL-010 Signal relay ;XJL-015 Signal relay ;
XJL-020 Signal relay ;XJL-025 Signal relay ;
XJL-050 Signal relay ;XJL-075 Signal relay ;
XJL-100 Signal relay ;XJL-200 Signal relay ;
XJL-400 Signal relay ;DXJ-203 Signal relay ;
One . purpose
XJY-220/43AC220V Static signal relay
It is used in relay protection and automatic control device of power system , As an action indication signal .
Two . The meaning of the model
3、 ... and . Technical parameters
1 XJ Series signal relay is excited by rectangular pulse , Magnetic steel holding .
2 This relay is double winding . The working coil can be of voltage type , It can also be current type . The reset coil is of voltage type . The working current or voltage of the relay is long pulse , It can also be that the pulse is not less than 20mS Short pulse of .
3 With light action indication signal , The signal can be reset locally or remotely .
Technical conditions
1 Environmental reference conditions
ambient temperature :20±2℃
Relative humidity :45%- 75%
Atmospheric pressure :86-106KPa
2 Normal service conditions
ambient temperature :-10℃-+50℃
Ambient relative humidity : No more than 90%
Atmospheric pressure :80 -IIOKPa
Extreme temperature during storage and transportation : 25℃-+70℃
The altitude of the place of use : No more than 2500 rice
The surrounding medium in the service environment has no explosion hazard ; Does not contain corrosive gases ; The concentration of conductive dust contained shall not reduce the insulation level below the allowable limit .
Reliable power supply .
3 Action value and reset value : No more than 70% Rating .
4 High power consumption
Voltage coil : At rated voltage 220VDC The lower limit shall not be greater than 6W
Coil current : No more than 1 5W
5 Large contact capacity :
Cut off load capacity : Direct 250V following ,t=5ms, Perceptual load 50w, Resistive load I50W;
communication 250V following , load 1200VA;
Allow long-term on current :5A.
6 Insulation resistance : use IOOOV The megger shall measure the insulation resistance between each outgoing terminal and the housing locking screw, which shall not be less than IOMΩ.
7 Dielectric Strength : The locking screw of each outgoing terminal to the shell can withstand power frequency voltage 2000V, The same group of contacts can withstand power frequency voltage IOOOV, No breakdown after one minute .
8 Electrical life : The contact is 10000 times under rated load .
9 Mechanical life : The contact is three million times in the no-load state
Four , Wiring diagram
Use
1 Before using the relay, check whether the relay is damaged during transportation and storage , The relay screw fasteners shall be free from looseness .
2 According to the first 5 Terminal wiring diagram of bar , Working coil (I or U) And reset coil (UF) The polarity of shall not be connected wrong .
3 Current or voltage of the working coil of the selected signal relay 、 The voltage of the reset coil must be consistent with the electrical circuit of the application *.
4 Single relay test : With XJL (Y) Mouth mouth mouth /43、XJL(Y) Mouth mouth mouth /45 For example , The test wiring is shown in the figure below .
If the working winding is voltage type R The value is O.
If the working winding is current type , be R The value depends on the rated current of the working winding
5、 ... and , Shape and size
Ordering instructions :
The relay model and specification must be indicated when ordering 、 Power supply mode and setting range of auxiliary power supply 、 Structural form code 、 Wiring mode before or after the board 、 Quantity and other requirements .
Function of signal relay
1) Expand the scope of control . for example , When the control signal of multi contact relay reaches a certain value , It can be in different forms of contact groups , Simultaneous connection 、 Disconnect 、 Turn on the multiplex circuit .
2) Zoom in . for example , Sensitive relay 、 Intermediate relay, etc , With a very small amount of control , A circuit that can control a large amount of power .
3) Integrated signal . for example , When multiple control signals are input to the multi winding relay in the specified form , After comparison and synthesis , Achieve the predetermined control effect .
4) Automatically 、 remote control 、 monitoring . for example , The relay on the automatic device works with other electrical appliances , It can form a program control circuit , So as to realize automatic operation .
for example :XJY-220/43AC220V Static signal relay
One 、 summary
XJ Series static signal relay ( Hereinafter referred to as relay ), Used in protection and automatic control devices for AC and DC operation , Used as action indication signal .
The relay adopts imported ultra small components 、 Advanced electronic circuit design 、 Reasonable structure , It has the following distinctive features :
1、 The relay has an action indicator , It can be reset electrically , It can be reset manually , It is conducive to the establishment of automatic unattended requirements .
2、 responsive , Move fast , The defect that the original electromagnetic signal relay can not reflect the quick action indication signal of the vacuum switch is solved .
3、 The operating current range of current type relay is wide , from 0.01~2A, One specification can be used to replace the original multi specification relay , Greatly conducive to design 、 Choose .
4、 With magnetic retention memory function . The relay has no noise , Reliable movement .
5、 With multiple groups of dynamic contacts , It can meet the requirements of signal indication and telecontrol . It can be accessed at will LED Light plate or incandescent light plate .
6、 The shell form and terminal wiring are the same as the original electromagnetic base 、 Same size and shape , Can be completely DXM-2A、DX-8、DX-8G、DX-11、DX-11A、DX-31A、DX-31B、DX-32A、DX-32B. Long term use , The relay has no noise .
7、 The action instructions are clear 、 reliable , Long life .
Static signal relay is suitable for DC operated relay protection and automatic control circuit , As a signal indicator . With multiple groups of dynamic closing and holding 、 Dynamic closing instantaneous contact . Can completely replace DX-11、DX-11A And other fixed mounted electromagnetic signal relays .
Shanghai Joseph relay business department
边栏推荐
- A single element in an ordered array
- fluttertoast
- pull_ to_ refresh
- [daily record] - bug encountered in BigDecimal division operation
- Authentication principle of Ranger plug-in
- Analysis of blocktoken principle
- TCP三次握手为什么不是两次或四次
- Unhandled Exception: MissingPluginException(No implementation found for method launch on channel)
- 文件服务设计
- CMU15445 (Fall 2019) 之 Project#1 - Buffer Pool 详解
猜你喜欢

Golang treasure house recommendation

Hoo research | coinwave production - nym: building the next generation privacy infrastructure

Get to know the drawing component of flutter - custompaint
![分割链表[先取next再斩断链表防止断链]](/img/eb/708ab20c13df75f4dbd2d6461d3602.png)
分割链表[先取next再斩断链表防止断链]

软硬件基础知识学习--小日记(1)

NE555 waveform generator handle tutorial NE555 internal structure (I)

闭锁继电器YDB-100、100V

Multi graph explanation of resource preemption in yarn capacity scheduling

初识 Flutter 的绘图组件 — CustomPaint

P4 learning - Basic tunneling
随机推荐
The real topic of the 11th provincial competition of Bluebridge cup 2020 - crop hybridization
Mindjet mindmanager2022 mind map decompression installer tutorial
Join table query select generation
Chapter 53 overall understanding of procedures from the perspective of business logic implementation
Sword finger offer 18 Delete the node of the linked list
Listview in flutter application development
Tcp/ip protocol stack, about TCP_ RST | TCP_ ACK correct attitude
A proper job is a good job
【学习笔记】构造
A single element in an ordered array
女朋友说:你要搞懂了MySQL三大日志,我就让你嘿嘿嘿!
Error msb8031: building an MFC project for a non Unicode character set is deprecated
mustache语法
【2023联发科提前批笔试题】~ 题目及参考答案
分割链表[先取next再斩断链表防止断链]
Training discipline principle of robot programming
[LeetCode] 爬楼梯【70】
解析融合学科本质的创客教育路径
Day31-t1380-2022-02-15-not answer by yourself
魔王冷饭||#101 魔王解惑数量多与质量;员工管理;高考志愿填报;游戏架构设计