当前位置:网站首页>Ankerui motor protector has the functions of overload inverse time limit, overload definite time limit, grounding, starting timeout, leakage, underload, phase failure, locked rotor, etc
Ankerui motor protector has the functions of overload inverse time limit, overload definite time limit, grounding, starting timeout, leakage, underload, phase failure, locked rotor, etc
2022-06-12 08:15:00 【acrelwc】
Encore Wang Chong
Abstract : There are a large number of low-voltage motor equipment that need perfect protection and centralized control in the coal industry . This paper analyzes the production status and development trend of China's coal industry , The necessity and inevitability of using motor protector in coal industry are introduced .
key word : coal ; Motor protection ; Motor protector
0 summary
In the coal industry , There are many low-voltage motors 、 Wide distribution , It is an important mechanical power source for production . Coal enterprises in order to achieve automated production , Improve production efficiency , Realize telemetering for motor equipment 、 Telesignaling 、 remote control 、 Telecontrol 、 The demand for fault diagnosis and centralized control is very strong . Compared with the traditional thermal relay to protect the motor , Intelligent motor protector is protecting 、 control 、 Operation and maintenance, communication and other aspects are more suitable for the current informatization 、 automation 、 Integrated development of the coal industry .
1 Background introduction
Coal is China's basic energy , It accounts for nearly... In the composition of primary energy 7 become . In recent years , The domestic economy has developed steadily , China's coal industry will continue to maintain a vigorous development trend for quite a long time , The development prospect of China's coal industry is still broad . however , While China's coal industry has made great achievements , Some serious problems also need to be solved , among “ Backward production capacity , The overall technical level is low ” and “ The situation of work safety is grim ” These two problems are particularly prominent .
At present , The overall production technology of the coal industry is in urgent need of iterative upgrading , Modern production technology requires a high degree of automation , It puts forward higher requirements for the reliability and stability of motor equipment . meanwhile , There are many flammable and explosive places in the coal industry , Once an accident happens, the consequences are unimaginable . Based on these two basic situations , The thermal relay, which has been used in motor circuit by coal enterprises before, can no longer meet the protection requirements under the current development form of coal industry 、 Control demand , It has rich measurement functions 、 Protection function 、 Control function 、 Intelligent motor protectors for operation and maintenance records and bus communication are gradually replaced .
2 functional requirement
Coal washing industry , The main low voltage motor loads are : Sieves , Cyclone , Shallow trough , Jig , Centrifuge , The flotation machine , Filter press , pump , pressure filter , Flotation column 、 Coal plough 、 Crusher and other equipment .
In the coal mine project , Generally, the motor protector is required to have overload 、 The current is unbalanced 、 Phase failure 、 Over and under voltage and other protection functions , Voltage required 、 Current measurement to adapt to new IMCC Application , Communication function is required to realize centralized monitoring and control in the background . stay AC 660V In the system , Most of them need to be equipped with leakage protection function . Besides , For some downhole motor loads , It also needs to be matched with horse insurance “ Anti shake electricity ” function , Prevent the motor from shutting down due to voltage drop when unattended , Cause unnecessary damage .
therefore , In the coal industry , It is recommended to use ankerui ARD3M-K1-XX/SU L-60L1 Motor protector , At the same time, according to the field bus communication requirements , Optional Profibus( Code name CP)、Profinet( Code name PNET)、Modbus_TCP( Code name MCE) Wait for the communication protocol .
3 Product introduction
3.1 Product overview
ARD3M Intelligent motor protector ( Hereinafter referred to as protector ), Using single chip microcomputer technology , Applicable to rated voltage to 660V Low voltage motor circuit , Set protection 、 measurement 、 control 、 Communications 、 Integration of operation and maintenance . Its perfect protection function ensures the safe operation of the motor , With logic programmable function , It can meet a variety of control modes . Different communication modules can be selected to meet the needs of field communication .
The product adopts split structure , By subject 、 Display unit 、 Transformer and optional communication module , It can adapt to the installation of various cabinets .
3.2 Technical parameters

3.3 Product features
■ The type of auxiliary power supply is optional ,AC220V The power supply module supports the power supply range AC85-265V/DC100-300V,AC380V The power supply module supports the power supply range AC/DC100-415V.
■ Support fundamental and full wave power parameter measurement (U、I、P、Q、S、PF、F、EP、EQ), Voltage and current imbalance , voltage 、 Current positive sequence 、 negative sequence 、 Zero sequence component , Three phase voltage phase angle , Residual current , voltage 、 electric current 2-63 Sub harmonic measurement , Sub harmonic content and total harmonic distortion .
■ The protection function includes overload inverse time limit 、 Overload time limit 、 Grounding 、 Start timeout 、 Electric leakage 、 Underload 、 Phase failure 、 Locked rotor 、 Blocking 、 A short circuit 、 overflow 、 out-off-balance ( electric current 、 voltage )、 Overpower 、 Under power 、 Overvoltage 、 Undervoltage 、 Phase sequence 、 temperature 、tE Time 、 External fault 、 The number of starts is limited 、 Run time alarm 、 Number of failures and alarms .
■ 10 Way programmable DI Input , The default is built-in DC24V Power Supply , External active wet contact can also be selected ( See model selection table for details ).
■ 6 Way programmable DO Output , Meet the requirements of direct starting , star — Delta start , Autotransformer starting , And so on , The remote control of the motor by the master station can be realized through the communication bus “ rise / stop ”.
■ Optional anti shake function : Support immediate restart after power shaking 、 Loss of pressure restart .
■ Standard configuration 2 road MODBUS_RTU Communications , Yes PROFIBUS DPV1、 Ethernet 、PROFINET Communication module optional .
■ Optional 2 road DC4-20mA Analog output interface , And DCS The system is connected , It can realize the monitoring of field equipment .
■ Have fault records 、 Start up record 、 Parking record 、DI All kinds of event records such as displacement record and restart record , You can view a number of motor operation and maintenance information , At the same time, motor operation can be recorded 1-5 Hour operation record .
■ The display interface supports / Display in English .
■ Support U Export waveform record and event record data from disk , You can use EXCEL Open the export event log file .
■ Optional color LCD display can be added WIFI function , Connect the... Via your mobile phone or computer WIFI see 、 Set relevant data of motor protector .
Typical performance

4 Conclusion
At present, the coal industry is in the process of industrial upgrading 、 The critical period of resource integration , A large number of renovation projects are in urgent need of functional perfection 、 Reliable motor protector . This article introduces ancorey ARD3M Series motor protector , Compared with previous generation products , Protecting 、 measurement 、 The operation and maintenance, control and other dimensions have been greatly upgraded , To improve the stability and reliability of production and operation of coal enterprises Provided security .
边栏推荐
- PPP agreement
- CMAKE 里PRIVATE、PUBLIC、INTERFACE属性示例详解
- Final review of Discrete Mathematics (predicate logic, set, relation, function, graph, Euler graph and Hamiltonian graph)
- js中的正则表达式
- S-msckf/msckf-vio technical route and code details online blog summary
- Vscode的Katex问题:ParseError: KaTeX Parse Error: Can‘t Use Function ‘$‘ In Math Mode At Position ...
- Hands on deep learning -- activation function and code implementation of multi-layer perceptron
- Asp Net project add log function
- 计组第一章
- Group planning chapter I
猜你喜欢

从AC5到AC6转型之路(1)——补救和准备

Talk about the four basic concepts of database system

Map the world according to the data of each country (take the global epidemic as an example)

Ten important properties of determinant

Hands on deep learning -- activation function and code implementation of multi-layer perceptron

Record the treading pit of grain Mall (I)

Face recognition using BP neural network of NNET in R language

(P15-P16)对模板右尖括号的优化、函数模板的默认模板参数

(p36-p39) right value and right value reference, role and use of right value reference, derivation of undetermined reference type, and transfer of right value reference

DUF:Deep Video Super-Resolution Network Using Dynamic Upsampling Filters ...阅读笔记
随机推荐
Convolutional neural network CNN based cat dog battle picture classification (tf2.1 py3.6)
Literature reading: deep neural networks for YouTube recommendations
ctfshow web4
Hands on deep learning -- Introduction to linear regression model
visual studio2019的asp.net项目添加日志功能
System service configuration service - detailed version
Beidou satellite navigation system foundation part 1
Transformation from AC5 to AC6 (1) - remedy and preparation
Three data exchange modes: line exchange, message exchange and message packet exchange
Map the world according to the data of each country (take the global epidemic as an example)
vm虚拟机中使用NAT模式特别说明
You get download the installation and use of artifact
Py&GO编程技巧篇:逻辑控制避免if else
Face recognition using BP neural network of NNET in R language
2.2 链表---设计链表(Leetcode 707)
vm虛擬機中使用NAT模式特別說明
企业上线MES软件的费用真的很贵?
FPGA generates 720p video clock
. net mysql Too many connections
建立MES系统,需要注意什么?能给企业带来什么好处?