2022 year 4 month 8 Japan , A customer calls to inquire about using DSX2-8000 When choosing test standards “+PoE” and “+All” Options , I don't know the difference between the standard without this symbol and the ordinary standard ? I have to mention that , This is the same as before DTX series , such as DTX-1800, The difference between the test results , The following items are more than traditional test parameters :
1.TCL( Transverse conversion loss );
2.ELTCL( Transverse conversion transmission loss );
3.CDNEXT( Common mode to differential mode near end crosstalk );
4.CMRL( Common mode return loss ).

Let's talk about fluke cable certification tester in detail . When testing twisted pair wiring , Some key parameters need to be set on the tester to test that the permanent link meets the industry standard parameters , Such as Insertion loss 、NEXT、PSNEXT、ACR-N、PSACR-N、ACR-F、PSACR-F And return loss . In the test Cat 6A( or ISO11801 The standard Fa class ) when , We also use PSANEXT( Integrated external near end crosstalk ) and PSAACR-F( Integrated external far end crosstalk ) Conduct external Crosstalk Test .
Although the required parameters will be automatically tested according to the test limits you choose , But have you noticed the of fluke network DSX There are (+All) Suffix series test this option , Want to know what this means , Why and when should I choose it ?
Fluke DSX The latest version of series tester 6.1 Simplified identification of limits , And in many TIA and ISO The bottom of the limit provides “+PoE” and “+All” Options . If these are not checked , Then only the field test limit is displayed . Choose them , The list will follow “(+PoE)”“(+All)” The measured value of the version is added to the list and becomes longer .
When you choose with (+PoE) or (+All) When testing the suffix , You are actually adding ANSI/TIA or ISO/IEC Other test parameters not required for field testing . about “+PoE”, These measurements are internal DC resistance imbalance and inter pair DC resistance imbalance , And the limit value of DC loop resistance .”+“ all ” Including these and ELTCTL、TCL、CMRL and CDNEXT Measured value . Although field tests do not require these additional measurements , But manufacturers need many of these parameters to establish compliance , This is why you will find them listed on the wiring specification sheet .
Although for certification purposes , You may not need to test these limits , And they do increase your testing time slightly , But they can provide you with more information about the performance of cabling equipment . Let's take a closer look , To help you decide whether to choose (+PoE) or (+All).
TCL and ELTCL
Ethernet signals are used in differential mode , Noise signal is applied to common mode . When noise is injected into the cable , Part of the common mode signal can be converted into differential mode , And become part of the Ethernet signal . This phenomenon, called mode switching, is not a good thing for Ethernet signals .
TCL( Transverse conversion loss ) and TCTL( Transverse conversion transmission loss ) Are two parameters for measuring mode conversion .TCL Measure the mode conversion of one end to the inside ,TCTL Measure the mode conversion inside the other end . However , because TCTL The common mode semaphore under test depends on the link length caused by insertion loss , So you have to use ELTCTL( Isoelectric level TCTL) Balance .
TCL and ELTCTL Only about 6 Second test time , They are excellent indicators of noise immunity and whether cable links can provide sufficient performance in a noisy environment , Including external crosstalk from adjacent cables or from other external sources ( Such as noise in industrial environment ). therefore , If you install in a noisy environment , And a simple method is needed to determine the noise resistance , Then you may need to choose (+All). Besides , It can reassure you in the manufacturer's statement , And it is an ideal choice for troubleshooting – fault TCL and ELTCTL It may cause bit error and retransmission , Even if other required transmission parameters provide a good margin above the standard limit .
CDNEXT and CMRL
CDNEXT( Common mode to differential mode near end crosstalk ) Is a parameter for troubleshooting only , The manufacturer does not need this parameter , And in TIA or ISO/IEC There is no test limitation specified in the standard . However ,TSB-1197“ Mode conversion parameters of balanced twisted pair wiring ” This is mentioned in , To help wiring professionals better understand the impact of noise on twisted pair wiring , Including external crosstalk and other external sources .
CDNEXT Is the difference between the common mode voltage and the differential mode voltage applied to a pair .
Voltage measured on other pairs at the same end of the cable . better CDNEXT Value corresponds to better noise immunity and lower emission . because CDNEXT It mainly appears in the connection hardware , So bad CDNEXT It's mainly about connector selection , May indicate low quality . It's unlikely that , But it may also be a process problem .
CMRL( Common mode return loss ) Is the difference between the common mode signal power applied to the pair and the reflected common mode signal power . These signal reflections are caused by changes in cable impedance , It may only be worthwhile to support transmission speeds that exceed 10 Gig Analysis of cabling equipment , Although the manufacturer did not require , There is no test limit specified in the industry standard
Now? , You've got it DSX Series examples DSX2-5000 CH DSX2-8000 CH On the tester (+PoE) and (+All) The meaning of the suffix , You can decide whether to add these measurements .
I hope a little simple introduction , Can help you .
边栏推荐
- 机器学习之聚类
- 在Asp.net 中Cookie的用法
- 神经网络学习
- 2、 Openvino brief introduction and construction process
- 详解爬电距离和电气间隙
- 《Distilling the Knowledge in a Neural Network》知识蒸馏论文解读
- 1、 Amd - openvino environment configuration
- Adaface: quality adaptive margin for face recognition image quality adaptive edge loss for face recognition
- USB Network Native Driver for ESXi更新到支持ESXi7.0 Update 2
- D2SC-GAN:基于双深浅通道生成对抗网络的课堂场景低分辨率人脸识别
猜你喜欢

杭州某公司福禄克FLUKE DTX-SFM2单模模块-修复案例

基于差值扩展的可逆水印方法

光伏发电系统——mppt最大功率点追踪

电快速脉冲群(EFT)设计-EMC系列 硬件设计笔记4

开关电源电路EMI设计在layout过程中注意事项

(PHP graduation project) obtain the campus network repair application management system based on PHP

四、模型优化器与推理引擎

Overview of unconstrained low resolution face recognition III: homogeneous low resolution face recognition methods

论福禄克DTX-1800如何测试CAT7网线?

详解爬电距离和电气间隙
随机推荐
Never leave its origin - bluecms1.6 vulnerability of the controller's shooting range
TCL和ELTCL?CDNEXT和CMRL?
The difference between router and switch
三、OpenVINO实战:图像分类
开关电源电路EMI设计在layout过程中注意事项
(PHP graduation project) based on thinkphp5 community property management system
Nsctf web Title writeup
Reinforcement learning - continuous control
ESXi Arm Edition version 1.10更新
Interviewer: let you design a set of image loading framework. How would you design it?
Why is the kotlin language not popular now? What's your opinion?
Tf.keras build neural network function expansion
Difference between shallow copy and deep copy
Deploy the project to GPU and run
基于tensorflow搭建神经网络
(PHP graduation project) obtained based on thinkphp5 campus news release management system
(PHP graduation project) obtain the campus network repair application management system based on PHP
关于隔离电源断电瞬间MOSFET损坏问题分析
(PHP graduation design) obtained based on PHP fruit sales store management system
ESXi社区版NVMe驱动更新v1.1