当前位置:网站首页>Double position relay jdp-1440/dc110v
Double position relay jdp-1440/dc110v
2022-06-27 05:18:00 【Comprehensive operation of Shanghai Joseph Electric Appliance C】



brand : Shanghai Joseph
name : Terminal block static two position relay
model :JDP-1440;JDP-1600
Rated voltage :48,110,220VDC/AC
Power consumption :≤2W
Contact capacity :5A/250V
Action time :≤30mS
Series models :
JDP-1004 Terminal block static two position relay ;
JDP-1440 Terminal block static two position relay ;
JDP-1220 Terminal block static two position relay ;
JDP-1110 Terminal block static two position relay ;
JDP-1222 Terminal block static two position relay ;
JDP-1202 Terminal block static two position relay ;
JDP-1008 Terminal block static two position relay ;
JDP-1600 Terminal block static two position relay ;
Two position relay JDP-1440/DC110V
■ It is mainly applicable to various protective devices , With magnetic
Keep function , To achieve mechanical locking , And there is a position prompt .
■ Its function and DLS Electromagnetic two position relay is compatible .
■ AC / DC dual purpose
■ Quick guide rail mounting structure , Suitable for all kinds of guide rail installation .
■ Screw crimping terminal .
■ Dimensions :86×85×73
Rating
Voltage type DC/AC Action value Power consumption
48V DC ≤75%
AC ≤80%
( Rating )
The action time shall not be greater than 2W 110V
220V
notes : The above parameters are 20℃ Test under conditions .
Contact parameters
Contact form ( See terminal diagram )
Breaking capacity
250V The following DC inductive circuits (5±0.75mS) 50W(30W)
250V The following AC circuits (Cos 0.4±0.1) 250VA (125 VA)
High current 5A(2A)
Electrical life The contact circuit is under the load conditions specified above 10 Ten thousand times
notes :JDP-1008 The specification contact parameters are the values in brackets .
Working conditions
Temperature range -10℃~+50℃
Relative humidity 5%~90% RH
Atmospheric pressure 80~110Kpa
impact
stability 98m/s
2
Strength 980m/s
2
Vibration 10Hz~55Hz 1.5mm Double amplitude
Form of leading out end Screw crimp type
weight 125g
Package form Plastic shell
performance Parameters
Insulation resistance ≥300 MΩ
Medium strength
Between relay circuit and contact 2000V AC 1min
Between contact groups 2000V AC 1min
Disconnect between contacts 1000V AC 1min
Action time ≤30ms
Model description
JDP 1 000 / XXX
Two position relay
Serial number
Contact form ( Dynamic closing 、 Move and break 、 transformation )
Rated voltage
Contact form :
Dimensions :
Ordering instructions
The relay model and specification must be indicated when ordering 、 Structural form code 、 Wiring mode before or after the board 、 Quantity and other requirements .
Two position relay JDP-1440/DC110V
Static guide rail two position relay is used in various protection and automatic control devices that need large capacity bistable contacts , As a switch 、 To achieve the locking effect , With position indication . It is an updated product of the old electromagnetic two position intermediate relay in power system and automation control .
Two position relay , As the name suggests, it means that the relay has two positions , At the same time, it can keep itself in both positions . actually , The two position relay is a magnetic holding relay with two coils .
coil A After power on , Relay contacts act , Even if it loses power , The contacts do not return ; coil B After power on , Relay contact return , Even if it loses power , The contacts will no longer act . in other words , If the contact position of the two position relay is reversed , There must be a coil live .
Two position relay is common in secondary circuit of substation , Mostly used to maintain status 、 In the circuit with high reliability requirements . Such as voltage switching circuit of double bus connection and voltage parallel circuit .
“ Two coils , Each coil is connected with a contact in series , One normally open and one normally closed , The force exerted by a magnet when there is no electricity , Fix the armature in the initial position , When the coil of normally closed contact station is powered on , When the coil is energized, the armature moves , After the action, the magnet will fix it at the position after the action , At the same time, the armature acts to make the series connection point of the two coils Set switch , The original normally closed contact is open , De energize the coil , The original normally open contact is closed , At the corresponding coil Ready to power on . Because it is held mechanically by a magnet , Therefore, after the control power supply disappears, its position will remain in the control position The state before the power supply disappears , It will not return to the original state after power loss like the electric hold relay .”
Shanghai Joseph relay business department
边栏推荐
- 微信小程序WebSocket使用案例
- 015 C语言基础:C结构体、共用体
- 洛谷P2939 [USACO09FEB]Revamping Trails G 题解
- EasyExcel合并相同内容单元格及动态标题功能的实现
- 014 C language foundation: C string
- 【B站UP DR_CAN学习笔记】Kalman滤波1
- leetcode299周赛记录
- RTP sending PS stream tool (open source)
- stm32读取IO高低电平状态
- Vue学习笔记(五)Vue2页面跳转问题 | vue-router路由概念、分类与使用 | 编程式路由导航 | 路由组件的缓存 | 5种路由导航守卫 | 嵌套路由 | Vue2项目的打包与部署
猜你喜欢
随机推荐
Chapter 1 Introduction
py2neo基本语法
Almost because of json Stringify lost his bonus
高翔slam14讲-笔记1
流媒体协议初探(MPEG2-TS、RTSP、RTP、RTCP、SDP、RTMP、HLS、HDS、HSS、MPEG-DASH)
STM32 reads IO high and low level status
Microservice system design -- message caching service design
Flink生产问题(1.10)
【B站UP DR_CAN学习笔记】Kalman滤波3
The most detailed download tutorial of MySQL
Edge在IE模式下加载网页 - Edge设置IE兼容性
Microservice system design -- distributed lock service design
OpenCV的轮廓检测和阈值处理综合运用
015 C语言基础:C结构体、共用体
微信小程序WebSocket使用案例
How JQ gets the ID name of an element
Neo4j database export
DAST 黑盒漏洞扫描器 第六篇:运营篇(终)
010 C language foundation: C function
008 C语言基础:C判断