当前位置:网站首页>Digi restarts XBee Pro S2C production. Some differences need to be noted
Digi restarts XBee Pro S2C production. Some differences need to be noted
2022-07-04 14:25:00 【Shanghai ChenKe XBee】
Digi Of XBee PRO S2C Module due to the upstream supplier PA And other components are discontinued , It was once forced to stop production , Many users have to use ordinary S2C replace , Or steering XBee3 Enhanced models . however S2C Ordinary type signal is weak , And turn XBee3 You need to do some adaptation on the software , It doesn't seem very convenient . lately , Due to the tight supply chain ,XBee3 It was once difficult to grab spot resources in the market , Fortunately Digi hold XBee PRO S2C A new one PA, Re production , This gives XBee Users provide more options .
At present, there are three models that can be booked :
new edition S2C PRO model | Corresponding to the original model | Description |
XBP24CZ7RIS-005 | XBP24CZ7RIS-004 | ZigBee, RF Pad, Surface Mount |
XBP24CZ7UIS-005 | XBP24CZ7UIS-004 | ZigBee, U.FL, Surface Mount |
XBP24CDMPIS-005 | XBP24CDMPIS-004 | DigiMesh, PCB Antenna, Surface Mount |
It should be noted that , This is a change PA New version of the design XBee PRO S2C, There is a small difference between it and the original , It is mainly caused by circuit change , The original DIO9 Pins cannot be used . Because this pin is also a wake-up indication pin . So when doing replacement , Pay attention to whether it matches the original hardware circuit . namely , If the previous circuit used this DIO9 do GPIO Or wake-up instructions , You need to modify the circuit or modify the software to adapt .
The function of the sleep module to wake up the indicator pin can also be realized through CTS To achieve ,CTS And this wake-up indication pin is reversed , Function as . Generally in hardware design ,CTS Pins are often used , Therefore, if the original circuit has these two pin designs at the same time , Function substitution can be realized through software .
in addition , new edition XBee pro S2C Compared with the old one , I won't support it 802.15.4 agreement .
In the long run ,XBee3 replace S2C Is the trend , If the hardware circuit needs to be changed , Suggest using XBee3 replace S2C, In PetroChina A11 And other projects , Due to the interaction of different manufacturers , Some scenarios also need to be matched in software , To ensure that the original usage can be seamlessly migrated to new products .
Specifications | Digi XBee-PRO Zigbee |
---|---|
performance | |
Transceiver chipset | Silicon Labs EM357 SoC |
Data rate | radio frequency 250Kbps, Serial up to 1 Mbps |
indoor / City scope *. | The longest 90 rice (300 feet ) |
Outside / RF line of sight *. | the height is 3200 rice (2 miles |
Transmission power | 63 mW (+18 dBm) |
Receiver sensitivity (1%/) | -101 dBm |
characteristic | |
Serial data interface | UART,SPI |
Configuration method | API or AT command , Local or air (OTA). |
Frequency band | ISM 2.4 GHz |
Form factor | Surface mounting |
Anti interference | DSSS ( Direct sequence spread spectrum ) |
ADC INPUTS | (4) 10 position ADC Input |
Numbers I/O | 18, No, RSSI PWM |
Antenna options | SMT: RF pad ,PCB The antenna , or U.FL The connector |
Operating temperature | -40º C to 85º C (-40º F to 185º F) |
Size ( Long X wide X high | SMT:2.199 x 3.4 x 0.305 cm (0.866 x 1.33 x 0.120 in) |
Network and security | |
agreement | Zigbee PRO 2007, HA-Ready, Support binding / Multiplexing |
ENCRYPTION | 128 position AES |
Reliable packet delivery | retry / confirm |
IDS | PAN ID And address , colony ID And endpoints ( Optional ). |
channel | 15 Channels |
Power requirements | |
Supply voltage | 2.7 to 3.6V |
Send current | 115 mA @ 3.3 VDC |
Receiving current | 34 mA @ 3.3 VDC |
Power down current | <1 μA @ 25º C (77º F) |
Regulatory approval | |
The federal communications commission , USAID ( In North America ). | yes |
ETSI ( The European ) | No, |
RCM ( Australia and New Zealand ) | No, |
* The estimation of range number is based on free air terrain and limited interference sources . The actual range will depend on the transmit power 、 Direction of transmitter and receiver 、 The height of the transmitting antenna 、 Height of receiving antenna 、 Weather conditions 、 The interference sources in the area and the terrain between the receiver and the transmitter ( Including indoor and outdoor structures , Like a wall 、 tree 、 building 、 Hills and mountains ) And change .
边栏推荐
- Remove duplicate letters [greedy + monotonic stack (maintain monotonic sequence with array +len)]
- opencv3.2 和opencv2.4安装
- Data warehouse interview question preparation
- Progress in architecture
- 2022 game going to sea practical release strategy
- 学内核之三:使用GDB跟踪内核调用链
- Nowcoder rearrange linked list
- How to package QT and share exe
- 商业智能BI财务分析,狭义的财务分析和广义的财务分析有何不同?
- 为什么图片传输要使用base64编码
猜你喜欢
92.(cesium篇)cesium楼栋分层
实时数据仓库
Ruiji takeout notes
Leetcode 61: 旋转链表
Intelligence d'affaires bi analyse financière, analyse financière au sens étroit et analyse financière au sens large sont - ils différents?
数据中台概念
【MySQL从入门到精通】【高级篇】(五)MySQL的SQL语句执行流程
sql优化之查询优化器
flink sql-client. SH tutorial
潘多拉 IOT 开发板学习(RT-Thread)—— 实验3 按键实验(学习笔记)
随机推荐
【MySQL从入门到精通】【高级篇】(五)MySQL的SQL语句执行流程
Data center concept
[FAQ] Huawei Account Service Error Report 907135701 Common reasons Summary and Solutions
LiveData
Map of mL: Based on Boston house price regression prediction data set, an interpretable case is realized by using the map value to the LIR linear regression model
leetcode:6110. 网格图中递增路径的数目【dfs + cache】
Chapter 17 process memory
sql优化之查询优化器
R语言dplyr包summarise_if函数计算dataframe数据中所有数值数据列的均值和中位数、基于条件进行数据汇总分析(Summarize all Numeric Variables)
【MySQL从入门到精通】【高级篇】(四)MySQL权限管理与控制
Xcode 异常图片导致ipa包增大问题
软件测试之测试评估
Some problems and ideas of data embedding point
Learn kernel 3: use GDB to track the kernel call chain
Excel quickly merges multiple rows of data
R language ggplot2 visualization: gganimate package creates animated graph (GIF) and uses anim_ The save function saves the GIF visual animation
数据中台概念
电商系统中红包活动设计
Excel快速合并多行数据
如何游戏出海代运营、游戏出海代投