当前位置:网站首页>Is it necessary to calibrate the fluke dtx-1800 test accuracy?
Is it necessary to calibrate the fluke dtx-1800 test accuracy?
2022-07-28 21:48:00 【Shenzhen Weixin instrument】
Time to dial 1994 year , Fluke DSP Series copper cable tester was born , To 2004 Next year , synchronous DTX-1800 Series launch , Until then 2015 year DTX-1800 The series is fully offline .DSP The reigning time is 10 year , and DTX-1800 In office 11 years , And to arrive 2018 year 6 month 30 The official warranty of fluke was suspended on August th . From the above time points ,DTX-1800 series , It is just at a special stage of China's rapid economic development , At the same time, all kinds of testing requirements are gradually rigorous in a special period . Its stock on the market is very objective , Since fluke officials do not support maintenance 、 maintain 、 calibration , How to dispose of these stock equipment in the market ?
Slightly wire the weak current , That is, we usually say that friends who know about network cabling know , At present, most twisted pair cables used in the market are between CAT5E(100mHz)-CAT6A(500mHz), It is also the main part of the finished product shipment of cable manufacturers .
DTX-1800 The test bandwidth can reach 900mHz, In other words, it can fully meet the current market demand . Support TIA,ISO,GB50312 And customized by the manufacturer . You can test the length of the cable 、 Line sequence diagram 、 Insertion loss ( attenuation )、 Return loss 、 Near end crosstalk , All test parameters specified in the standard .
DTX-1800 It is indeed a classic twisted pair test instrument , First of all , Fall resistant ; second , Standby time factory ; Third , Stable , Low failure rate ; front 2 Points can be realized in the process of use , Let's take the third point , Take it out alone .
The hour hand points 2022 year 7 month 28 Japan , To present position DTX-1800, list 17 years , It's also possible to stop supporting from the original factory 9 year . In these long years , Everything happens . from DTX-1800 Vulnerable parts begin to talk .
1,DTX-CHA002 Interface of channel adapter - The first loss piece , Once the official suggestion 5000-1000 After 10000 tests, it has to be replaced . The reason is often plugging , Lead to pin Poor contact due to deformation of the needle , In addition, the exposure time is too long , Oxidation leads to .
2, Battery aging .
3, Screen failure , Like a flower screen , No display , Partial Aging leads to .
4, Accidental fall injury , As a result, the machine cannot be started normally .
5, Enter liquid , Cause the machine to burn .
Probably the above are the common hardware failures to be handled , But the most important point is accuracy recovery , That is, original factory calibration . Fluke FLUKE It is recommended to calibrate once a year , Ensure the test accuracy of the instrument .
Repair and calibration , Since fluke doesn't support it , How to repair and calibrate the fault ?
If you have the above situation, you can confide in me , I will definitely give you a satisfactory answer .
边栏推荐
- Cross domain transfer learning of professional skill word extraction in Chinese recruitment documents
- Explain C language 12 in detail (C language series)
- Uniapp progress bar customization
- 两个全局变量__dirname和__filename 、fs模块常用功能进一步介绍
- Discussion: if you want to land Devops, is it enough to only consider a good PAAS container platform?
- Leetcode linked list question - interview question 02.07. linked list intersection (learn linked list by one question and one article)
- Layout the 6G track in advance! Ziguang zhanrui released the white paper "6G unbounded AI"
- Automatic filling of spare parts at mobile end
- The ref value ‘xxx‘ will likely have changed by the time this effect function runs. If this ref......
- 技术选型Rust——事后分析
猜你喜欢
![Leetcode 19. delete the penultimate node of the linked list [knowledge points: speed pointer, recursion, stack]](/img/86/c74a63c3465efbed74c2bf059bac4f.jpg)
Leetcode 19. delete the penultimate node of the linked list [knowledge points: speed pointer, recursion, stack]

The University was abandoned for three years, the senior taught himself for seven months, and found a 12K job

如何优雅的设计工作流引擎(荣耀典藏版)

Leetcode linked list question - interview question 02.07. linked list intersection (learn linked list by one question and one article)

Research on the recognition method of move function information of scientific paper abstract based on paragraph Bert CRF

不用Swagger,那我用啥?

Storage and steps of phospholipid coupled antibody / protein Kit

Research on weapon equipment attribute extraction based on attribute word completion
![[geek challenge 2019] secret file & file contains common pseudo protocols and gestures](/img/aa/a169cdd8cc6cdfda6d2777511b4dd2.png)
[geek challenge 2019] secret file & file contains common pseudo protocols and gestures

LeetCode链表问题——142.环形链表II(一题一文学会链表)
随机推荐
Achieve waterfall effect
中文招聘文档中专业技能词抽取的跨域迁移学习
针对下一代Chromebook,联发科推出新款芯片组MT8192和MT8195
株洲市九方中学开展防溺水、消防安全教育培训活动
苹果M1处理器详解:性能及能效成倍提升,Intel酷睿i9也不是对手!
蚂蚁集团境外站点 Seata 实践与探索
基于Xception-TD的中华传统刺绣分类模型构建
Talk about row storage and column storage of database
比UUID更快更安全NanoID到底是怎么实现的?(荣耀典藏版)
An end-to-end aspect level emotion analysis method for government app reviews based on brnn
Hold high the two flags of 5g and AI: Ziguang zhanrui Market Summit is popular in Shencheng
The ref value ‘xxx‘ will likely have changed by the time this effect function runs. If this ref......
For the 1000 yuan 5g mobile phone market, MediaTek Tianji 700 released
ST法国三座工厂大罢工,芯片缺货情况或将更加严重!
It is said that Microsoft has obtained the supply license for Xianghua! Will Huawei usher in the full lifting of the ban?
How to design workflow engine gracefully (glory Collection Edition)
Cy3/Cy5/Cy5.5/Cy7荧光标记抗体/蛋白试剂盒(10~100mg标记量)
Four methods of multi-threaded sequential operation. Ask casually during the interview
Discussion: if you want to land Devops, is it enough to only consider a good PAAS container platform?
MSI Bao'an factory is on fire! Official response: no one was injured, and the production line will not be affected!