当前位置:网站首页>2022 test questions and answers for the latest national fire facility operator (senior fire facility operator)
2022 test questions and answers for the latest national fire facility operator (senior fire facility operator)
2022-07-26 16:07:00 【100% question bank app】
The 100% question bank provides Fire service operators Examination questions 、 Fire service operators Test prediction questions 、 Fire service operators The real exam question 、 Fire service operators Certificate examination question bank, etc , Provide online questions and brush questions , Online mock exam , Help you pass the exam easily .

1、 Common faults of combustible gas detection system circuit do not include ( )
A、 The combustible gas alarm controller has no display fault
B、 All combustible gas detectors in an alarm area are disconnected
C、 All combustible gas detectors in a circuit are disconnected
D、 A detector is out of line
answer :B
analysis : Common faults of combustible gas detection system circuit : The combustible gas alarm controller has no display fault. All combustible gas detectors in a circuit are disconnected. A detector is disconnected
2、 It was found that , The combustible gas alarm controller has no display , The reason why this failure is impossible is ( )
A、 The main power cord is not connected
B、 The standby power cord is not connected
C、 Fuse action ( damage )
D、 The detector is damaged
answer :D
analysis : The combustible gas alarm controller does not display the cause of failure :(1) The main power cord is not connected (2) The standby power cord is not connected (3) Fuse action ( damage ) Maintenance method :(1) Check insurance 、 Line condition (2) Reset / Replace the fuse
3、 The combustible gas detection and alarm system has a fault that all combustible gas detectors in a circuit are disconnected , The reason can't be ( )
A、 The power supply line of the detector is short circuited or disconnected
B、 The detector communication line is short circuited or disconnected
C、 The feedback line of the detector is short circuited or disconnected
D、 The circuit has a ground fault
answer :C
analysis : The reason why all combustible gas detectors in a circuit are disconnected :(1) The power supply line of the detector is short circuited or disconnected (2) The detector communication line is short circuited or disconnected (3) Maintenance method for grounding fault of this circuit :(1) Check the power supply of this circuit / Whether the communication connection line is disconnected , Connect the power supply of the circuit / Communication connection line (2) Check the power supply of the detector circuit with a multimeter / Whether there is a short circuit in the communication line , Check the short circuit fault (3) Use a megger ( Shake the watch ) Check the power supply of this circuit / The grounding resistance between the communication line and the earth . If the resistance value is less than the insulation requirements in the product manual, it is a ground fault , Use subsection method to check the grounding point of circuit and repair the grounding fault

4、 The combustible gas detection and alarm system has a fault that all combustible gas detectors in a circuit are disconnected , The following statement is not true ?( )
A、 Check the power supply of this circuit / Whether the communication connection line is disconnected , Connect the power supply of the circuit / Communication connection line
B、 Check the power supply of the detector circuit with a multimeter / Whether there is a short circuit in the communication line , Check the short circuit fault
C、 Use a megger ( Shake the watch ) Check the power supply of this circuit / The grounding resistance between the communication line and the earth .
D、 If the resistance value is greater than the insulation requirements in the product manual, it is a ground fault , Use subsection method to check the grounding point of circuit and repair the grounding fault
answer :D
analysis : The reason why all combustible gas detectors in a circuit are disconnected :(1) The power supply line of the detector is short circuited or disconnected (2) The detector communication line is short circuited or disconnected (3) Maintenance method for grounding fault of this circuit :(1) Check the power supply of this circuit / Whether the communication connection line is disconnected , Connect the power supply of the circuit / Communication connection line (2) Check the power supply of the detector circuit with a multimeter / Whether there is a short circuit in the communication line , Check the short circuit fault (3) Use a megger ( Shake the watch ) Check the power supply of this circuit / The grounding resistance between the communication line and the earth . If the resistance value is less than the insulation requirements in the product manual, it is a ground fault , Use subsection method to check the grounding point of circuit and repair the grounding fault
5、 The combustible gas detection and alarm system has a fault that all combustible gas detectors in a circuit are disconnected , It is suspected that the communication line of the detector is short circuited , Which tool is needed to troubleshoot ?( )
A、 Megger
B、 A multimeter
C、 Flow meter
D、 voltmeter
answer :B
analysis : When the detector communication line is short circuited , Check the power supply of the detector circuit with a multimeter / Whether there is a short circuit in the communication line , Check the short circuit fault .
6、 The combustible gas detection and alarm system has a detector disconnection fault , The following processing method is incorrect ?( )
A、 Connect the power supply of the detector / Communication connecting line
B、 Check the power supply of the detector circuit with a multimeter / Whether there is a short circuit in the communication line , Check the short circuit fault
C、 Check the power supply of the detector with a multimeter / Communication connecting line ,
D、 If the detector still cannot return to normal working state , Replace the detector
answer :B
analysis : The cause of a detector disconnection failure :(1) The connecting wire of the detector is disconnected (2) How to repair the damage of the detector :(1) Check the power supply of the detector with a multimeter / Communication connecting line , Connect the power supply of the detector / Communication connecting line (2) If the detector still cannot return to normal working state , Replace the detector
边栏推荐
- HaWe screw cartridge check valve RK4
- Alibaba cloud DMS MySQL cloud database report error, solve!!
- Paper: all models are wrong, but many are useful: all models are wrong, but many are useful: understand the importance of variables by studying a whole class of prediction models at the same time
- 一款可视化浏览器历史的 Firefox/Chrome 插件
- SAP ABAP 守护进程的实现方式
- 2022 what is your sense of security? Volvo asked in the middle of the year
- 可信隐私计算框架“隐语”开源专家观点集锦
- 十周岁生日快乐,Clojure
- 机器人手眼标定Ax=xB(eye to hand和eye in hand)及平面九点法标定
- spark-streaming状态流之mapWithState
猜你喜欢

TI C6000 TMS320C6678 DSP+ Zynq-7045的PS + PL异构多核案例开发手册(4)

PS + PL heterogeneous multicore case development manual for Ti C6000 tms320c6678 DSP + zynq-7045 (3)

parker泵PV140R1K1T1PMMC
FTP protocol

数智转型,管理先行|JNPF全力打造“全生命周期管理”平台

提问征集丨快来向NLLB作者提问啦!(智源Live第24期)
![API version control [eolink translation]](/img/3a/8a78e57a2474f33d011d91631fde74.jpg)
API version control [eolink translation]

操作系统迁移实战之在openEuler上部署MySQL数据库

German EMG electric actuator eb800-60ii

Teach the big model to skip the "useless" layer and improve the reasoning speed × 3. The performance remains unchanged, and the new method of Google MIT is popular
随机推荐
C# 给Word每一页设置不同文字水印
Bucher gear pump qx81-400r301
API version control [eolink translation]
SAP ABAP Netweaver 容器化的一些前沿性研究工作分享
Build resume editor based on Nocode
德国EMG易安基推动器ED301/6 HS
马斯克被曝绿了谷歌创始人:导致挚友二婚破裂,曾下跪求原谅
kalibr标定realsenseD435i --多相机标定
PAT甲级 1049 Counting Ones
中金财富证券安全吗 开户要多久
【工具分享】自动生成文件目录结构工具mddir
《From SICP to Lisp》视频回播
Research and application of the whole configuration of large humanoid robot
Teach the big model to skip the "useless" layer and improve the reasoning speed × 3. The performance remains unchanged, and the new method of Google MIT is popular
教大模型自己跳过“无用”层,推理速度×3性能不变,谷歌MIT这个新方法火了...
How to use job plug-in type to call a kettle job through ETL scheduling tool taskctl?
ES6高级-查询商品案例
Jmeter快速上手之接口测试
德国emg电动执行器EB800-60II
一文详解 Redis 中 BigKey、HotKey 的发现与处理