当前位置:网站首页>Current relay JL-8GB/11/AC220V
Current relay JL-8GB/11/AC220V
2022-07-30 11:18:00 【Shanghai Joseph Electric Co., Ltd. Comprehensive operation】



Series models:
JL-8GA/11 terminal block current relay; JL-8GA/12 terminal block current relay;
JL-8GA/13 terminal block current relay; JL-8GA/21 terminal block current relay;
JL-8GA/22 terminal block current relay; JL-8GA/23 terminal block current relay;
JL-8GB/11 terminal block current relay; JL-8GB/12 terminal block current relay;
JL-8GB/13 terminal block current relay; JL-8GB/21 terminal block current relay;
JL-8GB/22 terminal block current relay; JL-8GB/23 terminal block current relay;
Current relay JL-8GB/11/AC220V
I. Purpose
JL-8G series static current relays (hereinafter referred to as the relays) are used in motors, generators, transformers and transmission lines as overcurrent protection or overload and short-circuit starting elements of the AC circuit of the power system to give alarmssignal or clear fault.
2. Model classification and meaning
Three, product features
This series of relays are integrated circuit static relays; imported integrated circuits are used for operation and comparison; digital setting, using a three-position DIP switch to set the current value, wide setting range, small step difference, convenient and intuitive setting; high precision and errorSmall size, no need for calibration, fast action speed, high return coefficient, low power consumption Auxiliary power supply adopts switching power supply conversion, AC and DC universal, wide operating voltage range, simple wiring, can be stuck on 35mm standard rail, easy to install and small size.
four, technical conditions
Current setting range: 0.1~99.9A, setting step: 0.1A;
Return coefficient: overcurrent 0.90~0.95;
Setting error: average error of current setting ≤±3%, average error=(average value of 5 measurements - setting value) / setting value × power consumption: auxiliary power supply ≤ 5VA; startup power supply ≤ 1VA.
Insulation resistance: Between the live terminals of the relay to the exposed non-live terminals or the shell, measure with a megohmmeter with an open circuit voltage of 500V, and the insulation resistance is >300MΩ.
Dielectric strength: Between the live terminals of the relay exposed to the non-live terminals or the shell, it can withstand the AC voltage of 2KV╲50Hz, which lasts for 1 minute without breakdown or flashover.
Contact capacity: when the voltage does not exceed 250V, the long-term allowable current of the output contact is 5A;
Contact life: electrical life 105 times, mechanical life 106 times;
Operation time: ≤25ms (overcurrent 1.2 times the setting value, undercurrent 0.5 times the setting value).
Return time: ≤25ms (0.5 times the setting value for overcurrent, 1.2 times the setting value for undercurrent).
Auxiliary power supply: AC/DC 48V, 110V, 220V, please specify other voltage levels when ordering.
5. JL-8GB/13; JL-8GB/21 relay dimensions, opening dimensions and terminal diagrams
Current relay JL-8GB/11/AC220V
JL series static current relay (hereinafter referred to as the relay) is used as a starting element in overload and short circuit protection devices of generators, transformers and transmission lines.This relay is an integrated circuit static relay with high precision, low power consumption, fast action time, high return coefficient, intuitive and convenient setting, and wide range. After providing DC auxiliary power, it can completely replace electromagnetic current relays. The auxiliary power is converted by switching power supply., AC and DC universal, wide working range, can work reliably from 100-300v30 series electromagnetic current relays.The jl series static current relay adopts the DIP switch to set the current value, and the setting range is 0.1-99.9a. There is no need to verify the setting value to change the setting value.
1. The schematic diagram of the relay is shown in Figure 1.
2. This relay is a static relay, which is composed of imported integrated circuits.After the measured alternating current i~ passes through the isolation converter, the voltage ui proportional to the measured current is obtained in its secondary.After the constant value setting, rectification is performed, and the rectified pulse voltage is filtered by a filter to obtain a DC voltage uo proportional to ui.In the level detection, uo is compared with the DC reference voltage ue. If the DC voltage uo is lower than the reference voltage, the level detector outputs a positive signal to drive the outlet relay, and the relay is in the action state. On the contrary, if the DC voltage uo is higher than the reference voltageue, the level detector outputs a negative signal, and the relay is in an inactive state.
"The current relay mainly reflects the current change, and can play the role of current protection and control in the electrical circuit of the electrical equipment. The current relay is connected to the main circuit. When the current in the circuit reaches beyond the specified range of the current relayWhen the current value is reached, the main circuit will be tripped and related signals will be generated at the same time.Current relays are usually used in the circuit of automatic control of electrical appliances, to control the automatic switch of larger current through a smaller current, and to convert the circuit for safety protectioneffect.”
Specializing in the production of relays, power meters, computer integrated protection devices, motor protectors, power automation integrated control systems and other products.Prices and technical parameters of products such as microcomputer protection devices, relays, power meters, and power automation systems...
Shanghai Joseph Electric Division
边栏推荐
猜你喜欢

PL5920 SOT-23-6 21V、2A、600KHz同步降压DC/DC转换器

【云原生】-Docker安装部署分布式数据库 OceanBase

The package of idea is not hollow

vscode中写markdown格式笔记的配置过程和相关语法

深入浅出零钱兑换问题——背包问题的套壳

图像去噪——Neighbor2Neighbor: Self-Supervised Denoising from Single Noisy Images
![[AGC] Growth Service 2 - In-App Message Example](/img/fa/9190e45c1532aec908a6c68706629a.png)
[AGC] Growth Service 2 - In-App Message Example

Neural Network Study Notes 3 - LSTM Long Short-Term Memory Network

Still using Swagger?I recommend this interface management artifact with zero code intrusion

API 网关 APISIX 在Google Cloud T2A 和 T2D 的性能测试
随机推荐
oracle export dmp file type as "crash dump file"
第3章 信息收集
单片机开发之静态LED显示
Microsoft SQL服务器被黑客入侵 带宽被窃取
@RequestBody 和 @ResponseBody 详解
Still using Swagger?I recommend this interface management artifact with zero code intrusion
Database dirty reads, non-repeatable reads, phantom reads and corresponding isolation levels
PanGu-Coder: 函数级的代码生成模型
京东校招笔试题+知识点总结
鸿湖万联扬帆富设备开发板正式合入OpenHarmony主干
面试官:Redis中的布隆过滤器与布谷鸟过滤器,你了解多少?
Basemap and Seaborn
Database transactions, JDBC operations and data types
Performance testing of API Gateway APISIX on Google Cloud T2A and T2D
2022全球数字经济大会人工智能专场:AI安全受高度关注
TestNg整合Retry代码
RandLA-Net复现记录
HJY-F931A/YJ three-phase voltage relay
AIX shell获取前几个月时间
SQL language and paging rownum analysis in Oracle