当前位置:网站首页>Voltage relay HDY - vac - 1 A / 1-220
Voltage relay HDY - vac - 1 A / 1-220
2022-07-30 11:15:00 【Shanghai Joseph Electric Co., Ltd. Comprehensive operation】



Brand: Shanghai Joseph
Name: Voltage Relay
Model: HDY-A/2-1;HDY-A/1-110VDC-2
Voltage setting range 3~480V
Power consumption≤6W
Contact capacity 250V5A
Rated voltage 100,400VAC
Series models
HDY-A/1-110VDC-1 voltage relay; HDY-A/1-110VDC-2 voltage relay;
HDY-A/1-220VDC-1 voltage relay; HDY-A/1-220VDC-2 voltage relay;
HDY-A/1-110VAC-1 Voltage Relay; HDY-A/1-110VAC-2 Voltage Relay;
HDY-A/1-220VAC-1 voltage relay; HDY-A/1-220VAC-2 voltage relay;
HDY-A/2-110VDC-1 voltage relay; HDY-A/2-110VDC-2 voltage relay;
HDY-A/2-220VDC-1 voltage relay; HDY-A/2-220VDC-2 voltage relay;
HDY-A/2-110VAC-1 voltage relay; HDY-A/2-110VAC-2 voltage relay;
HDY-A/2-220VAC-1 Voltage Relay; HDY-A/2-220VAC-2 Voltage Relay;
Purpose
HDY
Series voltage relays are static, non-directional, momentary, AC voltage relays.It can be used in relay protection devices of generators, transformers and transmission lines as an action element for overvoltage protection or low voltage blocking.The relay is composed of an integrated circuit to form an execution loop, which has the characteristics of high sensitivity, fast action speed, low power consumption, and convenient setting.The situation directly controls the protected equipment.The relay action value is set by the dial switch and the coding switch on the panel.(Applicable to AC 50/60HZ)
Technical parameters
Rated voltage: 100VAC, 400VAC
Auxiliary power supply: 110V 220V(AC/DC)
Setting range: 3V-120V(UN=100V)
12V-480V(UN=400V)
Operation time: overvoltage: ≤50MS (1.2 times the setting value)
Under voltage:≤50MS(0.8 times the setting value)
Return time: Overvoltage: ≤50MS (when the instantaneous voltage changes from 1.2 times the setting value to zero)
Under voltage: ≤30MS (when the instantaneous voltage changes from 0.8 times to 1.2 times the setting value to zero)
Action is one-to-one: <1%
Rated value error:<±5%
Return coefficient: Overvoltage:>0.92 Undervoltage:<1.08
Power consumption: no more than 1VA at rated current (AC power consumption); under rated auxiliary DC voltage, power consumption before relay action is no more than 3W, and power consumption after action is no more than 6W (DC power consumption)
Contact Form: 2Z
Contact capacity: when the voltage is not greater than 250V; the long-term contact current is 5A; when the voltage is not greater than 250V; in a DC circuit with a circuit time constant L/R of 5MS, the contact breaking capacity is 50W; When the voltage is not greater than 250V; in an AC circuit with a power factor COSφ of 0.4, the contact breaking capacity is 250VA.
Voltage relay HDY-A/1-220VAC-1
Model Specifications
Voltage relay HDY-A/2-1;HDY-A/1-110VDC-2 wiring diagram:
HDY-A/2-1;HDY-A/1-110VDC-2 Voltage Relay Dimensions:
A voltage relay is an electronic control device, it has a control system (also known as an input loop) and a controlled system (also known as an output loop), usually used in automatic control circuits, it actually uses a smaller currentAn "automatic switch" to control larger currents.Therefore, it plays the role of automatic adjustment, safety protection, and conversion circuit in the circuit.Mainly used in relay protection devices of generators, transformers and transmission lines, as a starting element for overvoltage protection or low voltage blocking.
A voltage relay is an electronic control device, it has a control system (also known as an input loop) and a controlled system (also known as an output loop), usually used in automatic control circuits, it actually uses a smaller currentAn "automatic switch" to control larger currents.Therefore, it plays the role of automatic adjustment, safety protection, and conversion circuit in the circuit.Mainly used in relay protection devices of generators, transformers and transmission lines, as a starting element for overvoltage protection or low voltage blocking.Voltage relay is a measuring relay whose input quantity and characteristic quantity are voltage. It is divided into over-voltage relay and under-voltage relay.The former acts when the voltage value increases and reaches the set value, and then is in a post-acting state; the latter acts when the voltage value decreases and reaches the set value, and then is in a release state.Voltage relays include electromagnetic type and transistor type.
Shanghai Joseph Relay Division
边栏推荐
- 零代码开发入门:快速上手DIY函数公式的5个步骤
- 4. yolov5-6.0 ERROR: AttributeError: 'Upsample' object has no attribute 'recompute_scale_factor' solution
- spark udf accepts and handles null values.
- 2022全球数字经济大会人工智能专场:AI安全受高度关注
- log4js入门
- Drag and drop events, dataTransfer, getBoundingClientRect
- JSP 语法简介说明
- Drools 规则引擎一文读懂
- 单片机开发之LCD1602显示实验
- Typroa 替代工具marktext
猜你喜欢
随机推荐
零代码开发入门:快速上手DIY函数公式的5个步骤
电流继电器JL-8GB/11/AC220V
MySQL | Subqueries
The package of idea is not hollow
【梦想起航】
Log4j有哪几种日志级别呢?
Pytorch中 nn.Transformer的使用详解与Transformer的黑盒讲解
jmeter接口压力测试(一)
NLP领域的最新研究进展
Vim plugin GrepIt
MySQL database maintenance
2022全球数字经济大会人工智能专场:AI安全受高度关注
Drag and drop events, dataTransfer, getBoundingClientRect
张量篇-初步
VLAN相关知识点
mysql与redis 区别
Understanding of deadlock
Basemap and Seaborn
Database dirty reads, non-repeatable reads, phantom reads and corresponding isolation levels
Drools 规则引擎一文读懂









