当前位置:网站首页>【PCBA program design】Grip dynamometer program
【PCBA program design】Grip dynamometer program
2022-08-04 21:08:00 【Xicheng Weike Solution Development】

1. Technical Specifications of Grip Dynamometer
1) LCD display: 888.8
2) Rated range: 123KG
3) Graduation value: 0.1KG/0.1LB
4) Minimum weighing: 2KG/4LB
5) Unit: KG (default)/LB
6) Button: ON/OFF START
7) Overload prompt: "ERR" is displayed when it is greater than 123KG
8) Low voltage detection: 2.4±0.1V
9) Power supply voltage: 3.0V
10) Working current: <15ma
11) Quiescent current: <5ua
12) Boot mode: on/off button to power on
13) Shutdown time: 120S

2. Functions of Grip Dynamometer
1. Weighing:
①In the off state, press the button to turn on the power, return to zero normally, memorize the last unit, measure once, display the grip strength value, keep the display of the maximum grip strength value, turn off if there is no operation time, and display ERR if it exceeds 123kg, and return to display the maximum value after 3 secondsvalue.
②Press the START key to return to zero, wait for the measurement again, it is valid if it is greater than 5KG, and "HOLD" lights up
③Display the maximum grip strength value, the grip strength increases without returning to zero, refresh the grip strength value, the grip strength value returns to zero, the grip strength is greater than 5kg and keeps displaying the maximum grip strength value, less than 5kg displays 0.0kg, hold goes out, and waits for the next measurement.
2. Low voltage alarm: When the power supply voltage is lower than 2.4V±0.1V, it will display "Lo" when it is turned on, and it will turn off automatically after about 1 second.
3. Overload display: When the grip strength is greater than 123.00KG, "ERR" will be displayed, and the grip strength will be reduced to less than 123KG and return to normal measurement.
4. Calibration for the first time: After powering on, after returning to zero, put a weight above 30Kg, the version number will be displayed for 2 seconds, after the calibration zero point is stably obtained, it will display 40.0Kg, put a 40Kg weight, after it is stable, it will display 80.0Kg, put 80KgAfter the weight is stable, it will display 120.0Kg, put the 120Kg weight, write the calibration data after it is stable, and then display "PASS", the weight calibration is successful.
5 Secondary calibration of weight: (1). For the calibrated scale, you can press the on/off button "three short and one long" to display the version number to enter the calibration, press the button again, after it is stable, it can display 40.0Kg, the remaining steps are the same as 4 (to ensure accurate zero calibration, it is recommended to wait 2 seconds before placing the weight)
边栏推荐
- win10 uwp modify picture quality compress picture
- buu web
- 动手学深度学习_NiN
- 嵌入式分享合集28
- LayaBox---TypeScript---Example
- OD-Model【6】:YOLOv2
- How to make good use of builder mode
- Oreo域名授权验证系统v1.0.6公益开源版本网站源码
- How to understand the crawler's Scrapy framework in the simplest and most popular way?
- QT(41)-多线程-QTThread-同步QSemaphore-互斥QMutex
猜你喜欢
随机推荐
深度解析:为什么跨链桥又双叒出事了?
Cryptography Series: PEM and PKCS7, PKCS8, PKCS12
项目难管理?先学会用好甘特图(内附操作方法及实用模板)
dotnet compress Stream or file using lz4net
[TypeScript] In-depth study of TypeScript enumeration
C#之app.config、exe.config和vshost.exe.config作用区别
LINQ to SQL (Group By/Having/Count/Sum/Min/Max/Avg操作符)
Data warehouse (1) What is data warehouse and what are the characteristics of data warehouse
mdk5.14无法烧录
MATLAB中readtimetable函数用法
visual studio 2015 warning MSB3246
adb控制常用命令
js数据类型、节流/防抖、点击事件委派优化、过渡动画
matlab 画图
vs Code runs a local web server
proe和creo的区别有哪些
伺服电机矢量控制原理与仿真(1)控制系统的建立
[Data Mining] Written Exam Questions for Sohu Data Mining Engineers
SAP ABAP OData 服务如何支持 $select 有选择性地仅读取部分模型字段值试读版
SPSS-System Clustering Hand Calculation Practice