当前位置:网站首页>Acreems energy efficiency management platform escorts the power safety of high-rise residential areas
Acreems energy efficiency management platform escorts the power safety of high-rise residential areas
2022-06-30 07:51:00 【Acrelhh】
How to prevent the occurrence of electrical fire in high-rise residential areas
Encore Cui Yuanhang
【 Abstract 】: With the development of the national economy and the continuous improvement of people's living standards , China's industrial power consumption and household power consumption are increasing year by year . Electrical fire causes huge casualties and property losses , It always threatens the safety of people's lives and property . as everyone knows , There are numerous examples of grounded electrical fires caused by damage to power supply lines or electrical equipment , Electrical fire monitoring system has been popularized and applied in high-rise residential areas with the improvement of the code for fire protection design of buildings .
【 key word 】: Electrical fire monitoring ; High rise community
Preface
Nearly period of time , There are more and more electric fires caused by electric vehicles going upstairs , In order to reasonably prevent electrical fire . Local fire departments organize special technical service personnel to carry out all-round inspection on residential quarters “ physical examination ” screening , In the spirit of leaving no dead ends 、 The principle of leaving no blind spots , Focus on electrical circuits 、 Cable tunnel 、 Cable shaft fire-fighting facilities and distribution cabinet 、 The elevator 、 Check the emergency facilities and other electrical equipment , For the electrical safety hazards found , according to “ First gear ” Establish customer hidden danger file information , Issue rectification notice on site , Clarify the possible consequences of these problems and hidden dangers if rectification measures are not taken in time , Put forward practical and feasible rectification suggestions according to the actual situation , Help users formulate practical and feasible rectification measures , Provide technical services , And assign special personnel to track and supervise the rectification , Promote reasonable implementation , Reduce the potential safety hazards of electrical fire .
Relevant standards
In order to reduce the occurrence of electrical fire , China has also issued a number of national standards , It aims to reduce the occurrence of fire , To protect the lives and safety of the people , Relevant instructions are also given for the design of electrical fire monitoring system .
●《 Electrical design standard for civil buildings 》GB51348-2019
13.2.2 In addition to the current national standards 《 Code for fire protection design of buildings 》GB50016 Outside the specified building or place , Electrical fire monitoring system shall be set for non fire-fighting distribution circuit of downstream civil buildings or places :
1、 Civil airport terminal , Bus passenger station , Port passenger station ;
2、 The building area is larger than 3000㎡ Hotel 、 Shopping malls and supermarkets ;
3、 The number of seats exceeds 1500 A movie theater 、 theatre , The number of seats exceeds 3000 A gymnasium , The number of seats exceeds 2000 A synagogue , The number of seats exceeds 20000 A stadium ;
4、 More books than 50 A library of ten thousand volumes ;
5、 Museums above the provincial level 、 Art Gallery 、 Cultural Center 、 Science and Technology Museum and other public buildings ;
6、 Ward Building of class III class B and above hospitals 、 Outpatient Building ;
7、 Provincial and municipal power dispatching buildings and above 、 Telecommunication building 、 Postal building 、 Disaster Prevention Command and dispatching building 、 Radio and television building 、 Archives building ;
8、 Urban rail transit 、 Class I traffic tunnel engineering ;
9、 Set underground 、 Semi underground or above ground four floors and above song and dance entertainment, projection and entertainment venues , Set on the first floor 、 Second and third floors and the building area of any floor is greater than 300㎡ Song and dance entertainment screening and entertainment place ;
10、 The kindergarten , in 、 Boarding houses in primary schools , Elderly care facilities .
●GB50016-2014《 Code for fire protection design of buildings 》
10.2.7 Electrical fire monitoring system should be set for non fire electrical loads of the following buildings or places :
1、 The building height is greater than 50m B of 、 Class C plant and class C warehouse , Outdoor fire water consumption is greater than 30L/s Factory building ( Warehouse );
2、 A class of high-rise civil buildings ;
3、 The number of seats exceeds 1500 A movie theater 、 theatre , The number of seats exceeds 3000 A gymnasium , The building area of any floor is greater than 3000㎡ Shops and exhibition buildings , province ( City ) Radio and television of grade and above 、 Telecommunications and finance, trade and finance construction , Outdoor fire water consumption is greater than 25L/s Other public buildings ;
4、 Ancient buildings with brick wood or wood structure in state-level cultural relics protection units .
AcrelEMS The energy efficiency management platform escorts the power safety of high-rise residential areas
In order to solve the power safety of high-rise residential areas , To ensure the lives and safety of the people ,AcrelEMS Energy efficiency management platform came into being . The scheme of the cloud platform is mainly divided into sources 、 network 、 Lotus 、 Store 、 charge 、 Several blocks of operation and maintenance , Study the energy flow and equipment of high-rise residential area EMS Centrally manage the flow of information transmission on the cloud platform .

meanwhile AcrelEMS Subsystem - Electrical fire monitoring system , Residual current for high-rise cells 、 Temperature, fault arc and other safety hazards are detected .
● Probe overview page : Through this interface, you can view the working conditions of each detector , Location information , And anomalies .

● Detector data page : This page allows you to view the real-time data of the detector , You can also run the curve , Understand the trend of detected data , And trends, etc .

● Host topology page : On this page, you can view the detector distribution of high-level cells , Networking information .

● Detector exception details page : Alarm records of detectors recorded to the page , Record the alarm time of the detector 、 Alarm type, etc .

High rise residential area electrical safety monitoring related hardware introduction
Electrical fire monitoring equipment

Electrical fire monitoring detector

On site installation display




Conclusion
I believe that today, with the rapid development of the Internet , Electrical fire monitoring system can be developed in more directions . At the same time, with the gradual attention of the society to electrical fire , People's awareness of the importance of electrical fire prevention in advance is also increasing . Electrical fire monitoring system provides a good early warning and monitoring function for high-rise residential areas , Reduce the use of manpower , Saved patrol time , It provides a strong guarantee for the safety of people's lives and property , It is also important to ensure the normal operation of the high-rise residential area , It has a very positive significance .
边栏推荐
- 【Tensorflow-gpu】window11下深度学习环境搭建
- Deep learning vocabulary representation
- 深度学习——词汇表征
- Cross compile opencv3.4 download cross compile tool chain and compile (3)
- November 22, 2021 [reading notes] - bioinformatics and functional genomics (Section 5 of Chapter 5 uses a comparison tool similar to blast to quickly search genomic DNA)
- Introduction notes to pytorch deep learning (11) neural network pooling layer
- 2022.01.20 [bug note] | qiime2: an error was encoded while running dada2 in R (return code 1)
- Simple application of generating function -- integer splitting 2
- November 9, 2020 [wgs/gwas] - whole genome analysis (association analysis) process (Part 2)
- Xiashuo think tank: 50 planet updates reported today (including the global architects Summit Series)
猜你喜欢

Final review -php learning notes 4-php custom functions

Final review -php learning notes 8-mysql database

Analysis of cross clock transmission in tinyriscv

直击产业落地 | 飞桨重磅推出业界首个模型选型工具

深度学习——目标定位

mysql无法连接内网的数据库

Deep learning - goal orientation
![December 19, 2021 [reading notes] - bioinformatics and functional genomics (Chapter 5 advanced database search)](/img/e9/8646f3e2da0ece853e7135eb6e30d9.jpg)
December 19, 2021 [reading notes] - bioinformatics and functional genomics (Chapter 5 advanced database search)

你了解IP协议吗?

多快好省,低门槛AI部署工具FastDeploy测试版来了!
随机推荐
JS代码案例
MCU essay
Tue Jun 28 2022 15:30:29 GMT+0800 (中国标准时间) 日期格式化
Deep learning -- recurrent neural network
深度学习——GRU单元
Introduction notes to pytorch deep learning (XII) neural network - nonlinear activation
2022 retail industry strategy: three strategies for consumer goods gold digging (in depth)
Solve the linear equation of a specified point and a specified direction
NMOS model selection
right four steps of SEIF SLAM
November 21, 2021 [reading notes] - bioinformatics and functional genomics (Chapter 5 advanced database search)
2021.11.20 [reading notes] | differential variable splicing events and DTU analysis
Firewall firewalld
Periodic planning work
Directory of software
Given a fixed point and a straight line, find the normal equation of the straight line passing through the point
Final review -php learning notes 5-php array
December 13, 2021 [reading notes] | understanding of chain specific database building
December 4, 2021 [metagenome] - sorting out the progress of metagenome process construction
期末复习-PHP学习笔记8-mysql数据库