1 Position of screen cabinet and auxiliary integrated monitoring host
- Panel cabinet position
The installation position is set in the monitoring machine room on the second floor of the main control building , Monitor the right side of the computer room sharing and network equipment screen , Cabinet equipment includes rack mounted servers 1 platform 、 Host of intelligent auxiliary monitoring management platform in power distribution room 、 Optical fiber switch at station control layer .
- Location of auxiliary integrated monitoring host
Respectively installed in 500KV 1 Protection chamber No GPS Minute clock screen 、500KV 2 Protection chamber No GPS Minute clock screen 、220KV 1 Protection chamber No GPS Minute clock screen 、220KV 2 Protection chamber No GPS Minute clock screen 、220KV 3 Protection chamber No GPS Minute clock screen 、 Main transformer reactive power protection chamber GPS Minute clock screen .
Access controller and auxiliary control host are powered on : Follow the guidance of the on-site work manager in the station to correctly access 220v Direct current . Pay attention to touching other operating equipment by mistake to prevent safety accidents , There must be certain protective measures for oneself , Wear insulated shoes 、 Cotton long sleeve overalls 、 Wear a helmet 、 Insulating gloves . The insulation of power lines and electrical equipment must be good , Wiring shall be neat , Protective measures shall be taken for exposed live parts of equipment
2 Access control system
(1)7 Installation of access control system for four rooms
The access control system is installed in 500KV 1 Protection chamber No 、500KV 2 Protection chamber No 、220KV 1 Protection chamber No 、220KV 2 Protection chamber No 、220KV 3 Protection chamber No 、380V Electricity Distribution Room 、 Main transformer reactive power protection chamber .
(2) Access control installation of main control building
The first floor of the main control building ( Communication machine room 、 Communication battery room 、 Safety tool room 、 Conference Room 、 Party and League activity room ).
The second floor of the main control building ( Monitor the machine room 、 Shift preparation room 、 Main control room 、 Station Master 、 Operation and maintenance studio 、 Resource Center ).
- Installation of substation gate
Install on the fence at one side of the electric door of the main control building 500*400*200mm The stainless steel waterproof distribution box is above the ground 1.5 M height , Complete the grounding device of the distribution box . Cut a groove on the inner side of the guide rail of the electric door and route it to the column of the security room , Grooving wiring to electric control box , Installation off the ground 1.5 M height : Exit button 2 individual , Card reader 2 individual .
3 environmental system
- Temperature and humidity sensor installation
The temperature and humidity sensor shall be installed close to the wall and above the ground 1.4 rice , Installed in the 7 A small room (500KV 1 Protection chamber No 、500KV 2 Protection chamber No 、220KV 1 Protection chamber No 、220KV 2 Protection chamber No 、220KV 3 Protection chamber No 、380V Electricity Distribution Room 、 Main transformer reactive power protection chamber ), The first floor of the main control building ( Communication machine room 、 Communication battery room 、 Safety tool room 、 Conference Room 、 Party and League activity room ), The second floor of the main control building ( Monitor the machine room 、 Shift preparation room 、 Main control room 、 Station Master 、 Operation and maintenance studio 、 Resource Center )
- Installation of water immersion sensor
Installed in the 7 A small room (500KV 1 Protection chamber No 、500KV 2 Protection chamber No 、220KV 1 Protection chamber No 、220KV 2 Protection chamber No 、220KV 3 Protection chamber No 、380V Electricity Distribution Room 、 Main transformer reactive power protection chamber ).
- Wind speed sensor 、 Atmospheric monitoring 、AP Installed on the roof of the main control building .
4 Auxiliary control system
- Air conditioning controller installation
The air conditioner controller is installed in the air conditioner ,7 A small room (500KV 1 Protection chamber No 、500KV 2 Protection chamber No 、220KV 1 Protection chamber No 、220KV 2 Protection chamber No 、220KV 3 Protection chamber No 、380V Electricity Distribution Room 、 Main transformer reactive power protection chamber ), The first floor of the main control building ( Communication machine room 、 Communication battery room 、 Safety tool room 、 Conference Room 、 Party and League activity room ), The second floor of the main control building ( Monitor the machine room 、 Shift preparation room 、 Main control room 、 Station Master 、 Operation and maintenance studio 、 Resource Center )
(2) Light control installation
Relay is installed in air switch power distribution box for light control ,7 A small room (500KV 1 Protection chamber No 、500KV 2 Protection chamber No 、220KV 1 Protection chamber No 、220KV 2 Protection chamber No 、220KV 3 Protection chamber No 、380V Electricity Distribution Room 、 Main transformer reactive power protection chamber ), The first floor of the main control building ( Communication machine room 、 Communication battery room 、 Safety tool room 、 Conference Room 、 Party and League activity room ), The second floor of the main control building ( Monitor the machine room 、 Shift preparation room 、 Main control room 、 Station Master 、 Operation and maintenance studio 、 Resource Center ).
5 Fire fighting system
Wiring from the auxiliary system cabinet of the monitoring room on the second floor of the main control building to the fire host in the main control room , Access 485 card , card , Communication protocol , The point position table shall be provided by the manufacturer
6 Security video system
(1)2 Video location installation
Respectively installed in 35kv Capacitor bank 311 Circuit breakers and 220kv 2 Southwest corner of No. 1 protection room . Keep a safe distance 4 Meter video pole . Cables are connected to 220kv 1 No. 1 protection chamber and 220kv 2 Protection chamber No
(2) Installation steps
The first step is foundation construction : The reinforcement on the foundation steel plate shall be in accordance with M20 Standard tapping , Equipped with two galvanized screws 、 One plain washer and one spring washer material :8mm The steel plate 、C25 concrete 、 Gravel 、2.5 Inch elbow .
Step 2 cable duct laying : The cable duct is well sealed , Good waterproof performance , The cable duct shall be no less than 0.7 rice , The cable pipe orifice shall be free of burrs and sharp edges .
Step 3 grounding : There shall be no pipeline below the installation point of grounding body 、 The cable passes through , Access to the ground network .
边栏推荐
- 看懂UML类图和时序图
- [100 unity step pit knowledge points] | collision box detection physics in unity OverlapBox、OverlapCaps
- 动手学数据分析 数据重构
- 为什么世界上只有13个根域名服务器
- I would like to ask you guys, the flick CDC will add a table level exclusive lock before extracting the full amount of Oracle data
- 6-Zabbix监控自动发现第三方中间件内存及CPU使用情况
- Nanjing University static program analyses -- Introduction learning notes
- 2022年CIO需要关注的九个趋势和优先事项
- 网页加载时waiting(TTFB)时间过长的问题解决
- Introduction to CPU, MPU, MCU, SOC and MCM
猜你喜欢

搭建zabbix监控及邮件报警

这3个后生,比马化腾、张一鸣还狠

DVWA configuration tutorial

华为是如何从0到1打造以项目为中心运作的项目管理体系的?

记一次Vmware虚拟机升级GLIBC导致系统瘫痪的恢复解决方法

Compilation de l'environnement vs Code + GCC développé par stm32

i. MX - rt1052 input / output (GPIO)

About SDRAM memory

Ansible operating instructions for configuring SSH authentication free for the first time

2-zabbix automatically add hosts using autodiscover
随机推荐
dicom格式转成nii.gz文件
~~~~配置
WPF uses Maui's self drawing logic
记一次Vmware虚拟机升级GLIBC导致系统瘫痪的恢复解决方法
动手学数据分析 数据重构
6. 函数
搭建zabbix监控及邮件报警
8 种最坑的SQL错误用法
Summary of UART problems in stm32cubemx
2. 引用
PWM (pulse width modulation) of STM32 notes
External attention tensorflow (under update)
一文掌握SQLite3基本用法
UML的六种关系-系统学习四
Workbench常见网格划分方法讲解
理解RESTful架构
EasyUI-input取/赋值
智能辅助系统在配电室内的施工方案 安装位置
findpanel的相关代码
typescript localStorage 封装