当前位置:网站首页>Leakage detection relay jy82-2p
Leakage detection relay jy82-2p
2022-07-04 05:42:00 【Comprehensive operation of Shanghai Joseph Electric Appliance C】



brand :JOSEF Joseph
Product model :JJB-380;JJB-380/660
The product name : Leak detection relay
Action current :0.03mA~9.99A
Working voltage :AC220V/AC380V
Action time :0.02~99.99S
Installation mode : Guide rail in cabinet / Embedded panel
Zero sequence aperture :25mm~220mm
Host size :883660mm
Series models :
JY82A Leak detection relay
JY82B Leak detection relay
JY82-380/660 Leak detection relay
JY82-IV Leak detection relay
JY82-2P Leak detection relay
JY82-2/3 Leak detection relay
JJKY Leak detection relay
JD Type leakage detection relay
JY82-IV;JY82J
JY82-II;JY82-III
JY82-1P;JY82-2PA;JY82-2PB
JJB-380;JJB-380/660
JD-127V/127V;JD-380V/380V;
JD-660V/660V;JD-1140V
KXL-2N;KXL-IV;KXL-1V
KXL-1N;KXL-2NA;KXL-2NB
KDJ-380V;KDJ-660V
KDJ-380V/380V;KDJ-660V/660V
JJKY-30;JJKY-30Ⅱ;JJKY-30Z
One 、 Product overview
Leak detection relay JY82-2P
Suitable for AC voltage to 660V Or higher TN、TT、 and IT System , The frequency is 50Hz. Detect the zero sequence current exceeding the setting value through the zero sequence current transformer ( The remaining ) Leakage current . The relay is connected with the circuit breaker of shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , Can be equipped with buzzer 、 Signal and other acoustooptic devices are combined to form a leakage alarm device . Derive multiple models , Prefix such as HLJ、RLJ、ULJ Series and other models , It is actually a similar product . It plays a very important role in the power system , It is the basis to ensure the reliability of power supply .
Two 、 Product use
The leakage protection relay has small volume 、 Easy to install and use 、 Reliable movement 、 Continuous power supply is stable and easy to operate . Can adapt to users everywhere , It can be used to protect the line from ground fault , It is mainly used to prevent equipment accident or electrical fire caused by grounding fault current , It can also be used to provide indirect contact protection for the release of human electric shock .
The leakage relay can be connected with the circuit breaker with shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , It can also be equipped with buzzer 、 Signal lamp and other acousto-optic devices are combined to form a leakage alarm device . With reset 、 instructions 、 Call the police 、 Reset and other functions .
It is not suitable for the central grounding point of power supply or direct grounding system 、 Low voltage distribution system . It is a network reform product for safe use . The action time of the relay is divided into fast type and delay type , When used together, the trunk line and branch line shall be protected by classification , It can completely replace the past LLJ-□F(S)、LLJ-□H(S)、JD1 And JD3 Series leakage relay .
The leakage relay can be connected with the circuit breaker with shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , It can also be equipped with buzzer 、 Signal lamp and other acousto-optic devices are combined to form a leakage alarm device . With reset 、 instructions 、 Call the police 、 Reset and other functions .
It is not suitable for the central grounding point of power supply or direct grounding system 、 Low voltage distribution system . It is a network reform product for safe use . The action time of the relay is divided into fast type and delay type , When used together, the trunk line and branch line shall be protected by classification , It can completely replace the past LLJ-□F(S)、LLJ-□H(S)、JD1 And JD3 Series leakage relay .
Rated current of the product 、 Leakage current 、 Transformer aperture . Rated voltage and working voltage . If delay is required , You have to specify the time .
1. Expand the scope of control : for example , When the control signal of multi contact relay reaches a certain value , It can be in different forms of contact groups , Simultaneous connection 、 Disconnect 、 Turn on the multiplex circuit .
2. Zoom in : for example , Sensitive relay 、 Intermediate relay, etc , With a very small amount of control , A circuit that can control a large amount of power .
3. Integrated signal : for example , When multiple control signals are input to the multi winding relay in the specified form , After comparison and synthesis , Achieve the predetermined control effect .
4. Automatically 、 remote control 、 monitoring : for example , The relay on the automatic device works with other electrical appliances , It can form a program control circuit , So as to realize automatic operation .
Shanghai Joseph relay business department
边栏推荐
- 1.1 history of Statistics
- RSA加密应用常见缺陷的原理与实践
- The difference between PX EM rem
- JS string splicing
- BUU-Reverse-easyre
- Void convolution, deformable convolution, deformable ROI pooling
- JS string splicing enhancement
- transformer坑了多少算力
- js arguments参数使用和详解
- Halcon image calibration enables subsequent image processing to become the same as the template image
猜你喜欢

Letter meaning and parameter abbreviation of optical module Daquan

Input displays the currently selected picture

Configure cross compilation tool chain and environment variables

724. 寻找数组的中心下标

LM小型可编程控制器软件(基于CoDeSys)笔记二十二:错误4268/4052

拓扑排序和关键路径的图形化显示

2022 R2 mobile pressure vessel filling retraining question bank and answers

每周小结(*63):关于正能量

Analysis of classical pointer and array written test questions in C language

LabVIEW错误对话框的出现
随机推荐
Write a complete answer applet (including single choice questions, judgment questions and multiple topics) (III) single choice questions, judgment questions, and the first question display
Excel comparator
SQL performance optimization skills
Etcd database source code analysis - initialization overview
冲击继电器JC-7/11/DC110V
Unity2d -- character moves and turns
Take you to quickly learn how to use qsort and simulate qsort
Recommended system 1 --- framework
tutle时钟改进版
js如何将秒转换成时分秒显示
XII Golang others
【QT】制作MyComboBox点击事件
拓扑排序和关键路径的图形化显示
Appearance of LabVIEW error dialog box
安装 Pytorch geometric
(4) Canal multi instance use
【雕爷学编程】Arduino动手做(105)---压电陶瓷振动模块
left_ and_ right_ Net interpretable design
2022 R2 mobile pressure vessel filling retraining question bank and answers
724. Find the central subscript of the array