Hqst Yingsheng electronic guide : In Ethernet devices , adopt PHY Pick up RJ45 when , A network transformer will be added in the middle , So how to judge whether the network transformer is good or bad , And what is the general symptom when it is broken ?
that How to judge whether the network transformer is good or bad ?
This should be discussed from two dimensions
One is the application of network transformer , That is to say, for non professional network transformer manufacturers, namely network transformer customers , Traders , How to judge the quality of the network transformer through non professional methods
1, In the application phase , The signal of the product suddenly is poor or Gigabit becomes 100m , The transmission distance is too short , We can check whether it is caused by network transformer and other reasons
2, If we now have a batch of unused network transformer products from unknown sources , The quality of this product does not belong to the ability of our terminal to identify and judge the quality itself , The best way is to find a professional network transformer manufacturer to conduct comprehensive product inspection and identification , The aspects of identification can also be divided into two levels
One aspect is the product appearance , Such as PIN Foot flatness , appearance , Packaging is good or bad , Tinning , Wire package , The thread ends are broken , A short circuit , Failure to clean leads to corrosion, etc ,
The second level is to test the electrical parameters of the product , Such as withstand voltage , inductance , Lap ratio , Equilibrium value ,PS, And the network parameter insertion loss of the product , Return loss, etc .

16PIN Ultra thin industrial network transformer H0068NL
What are the symptoms of a broken network transformer ?
After the network transformer broke down on the communication equipment application motherboard , Network communication will lead to various undesirable products , Such as increased signal noise , The network transmission rate decreases , Gigabit to 100m , The network port is blocked
For professional network transformer manufacturers , Different problems will show different parameters , Such as test after short circuit PS however , The inductance value is too large or too small , Insertion loss , Return loss parameters are not up to standard , The transmission of network communication signals reflects various defects , Poor voltage withstand, no surge at the mouth, etc
For network communication equipment , After normal use, there are sudden problems, such as network signal failure , Rate reduction can be considered as network transformer product damage , But it can only be listed as one of the problems to be checked , For a communication motherboard with many components , Sometimes the problem is not just a component problem , So there is not much reference significance for using individuals to solve this problem
For the network transformer product itself , The quality of a single product does not have much reference significance , We need to consider the manufacturer's overall quality control standard for the batch of network transformer products , Yes Hqst For Yingsheng Electronics , Our basic standard for quality control of network transformer products is to control the electrical defect rate within 0%, No defective product is allowed to flow out of the product line , Access terminal . The overall rate of all other defects such as appearance shall be controlled to the highest 800PPM following , Strictly speaking, we should control in 300PPM With a total defective rate of three tenths of a million

边栏推荐
- Initial environment configuration of the list of OpenGL super classic (version 7) vs2019
- Chapter 9 of OpenGL super classic (version 7): fragment processing and frame buffering
- Golan no tests were run: fmt Printf() < BUG>
- Chapter 11 advanced data management of OpenGL super classic (version 7)
- [typescript] experimentaldecorators of vscode stepping pit
- Detailed explanation of the loss module of mmdet
- pytorch中常用损失函数总结
- 很紧张,第一天做软件测试,需要做什么?
- GoLand No Tests Were Run : 不能使用 fmt.Printf() <BUG>
- Chapter 7 vertex processing and drawing commands of OpenGL super classic (7th Edition)
猜你喜欢
![[notes] unity Scrollview button page turning](/img/c7/47c4056871d0212ac61524539f0d0e.jpg)
[notes] unity Scrollview button page turning

Writing unityshader with sublimetext
![[note] usage model tree of the unity resource tree structure virtualizingtreeview](/img/3e/fe5610c797a14554ad735172c3ab54.jpg)
[note] usage model tree of the unity resource tree structure virtualizingtreeview

Force buckle 27 Removing Elements

Unity shader flat shadow

Basic operations of Oracle data

Unity project hosting platform plasticscm (learn to use 2)

Ugui uses its own function to realize reverse mask

Baiwen.com 7 days Internet of things smart home learning experience punch in the third day

Unity 3D model operation and UI conflict Scrollview
随机推荐
Xctf--Web--Challenge--area Wp
Detailed explanation of the loss module of mmdet
Force buckle 977 Square of ordered array
Unity project hosting platform plasticscm (learn to use 1)
Unity mobile end sliding screen rotation
终端便捷ssh(免密)连接
Unity profiler performance analysis
Responsive layout
Chinese pycharm changed to English pycharm
Unity3d- use animator and code to control task walking
Connect() and disconnect() of socket in C #
东塔攻防世界—xss绕过安全狗
2021-06-17 solve the problem of QML borderless window stretching, window jitter and flicker when stretching and shrinking
很紧张,第一天做软件测试,需要做什么?
Baiwen.com 7 days Internet of things smart home learning experience punch in the third day
Unity scroll view element drag and drop to automatically adsorb centering and card effect
Pit of smoothstep node in shadergraph
Ripple effect of mouse click (unity & shader)
3D rotation album
Unity application class and data file path