Brand: Shanghai Joseph
Name: Undervoltage Monitoring Relay
Model:SRMUVS-100VAC-2Z
Power consumption≤5W
Contact capacity 250V5A
Rated voltage 58,100,110,220VAC
Series models:
SRMUVS-58VAC-2H under-voltage monitoring relay; SRMUVS-100VAC-2H under-voltage monitoring relay;
SRMUVS-110VAC-2H under-voltage monitoring relay; SRMUVS-220VAC-2H under-voltage monitoring relay;
SRMUVS-58VAC-2H2D under-voltage monitoring relay; SRMUVS-100VAC-2H2D under-voltage monitoring relay;
SRMUVS-110VAC-2H2D under-voltage monitoring relay; SRMUVS-220VAC-2H2D under-voltage monitoring relay;
SRMUVS-58VAC-4H under-voltage monitoring relay; SRMUVS-100VAC-4H under-voltage monitoring relay;
Purpose
SRMUVT series under-voltage monitoring relays are suitable for relay protection devices of generators, transformers and substation lines as starting elements for low-voltage blocking.(Applicable to AC 50/60HZ)
The set value and hysteresis return of the relay can be infinitely adjusted by the potentiometer
Technical parameters
Rated voltage: 58V 100V 110V 220V(AC)
Rated voltage range: 35%-130% rated voltage
Setting value: 50%-105% rated voltage
hysteresis return coefficient: 2%-20% relative to the set value
Scale error: ≤6%
Temperature error: ≤5W
Contact capacity: when the voltage is not greater than 250V; the long-term contact current is 5A; when the voltage is not greater than 250V; in a DC circuit with a circuit time constant L/R of 5MS, the contact breaking capacity is 50W;When the voltage is not more than 250V; in the AC circuit with a power factor COSφ of 0.4, the contact breaking capacity is 250VA
Dielectric strength: The relay can withstand 50HZ, 2KV between the terminals and the shell for 1 minute without breakdown or flashover
Ambient temperature: -25℃-55℃
Can be installed on U-shaped 35 rail
SRMUVT-100VAC-2Z;SRMUVS-220VAC-2H2D under-voltage monitoring relay model specifications
Undervoltage monitoring relay SRMUVT-100VAC-2Z;SRMUVS-220VAC-2H2D wiring diagram:
Dimensions
Voltage relay SRMUVS-100VAC-2H2D
Voltage relay
It is a relay that operates when the voltage in the circuit reaches a predetermined value.Its structure is basically the same as that of the current relay, but the number of turns of the electromagnet coil is many, and it should be connected in parallel with the power supply when used.It is widely used in voltage loss (zero voltage) and undervoltage (low voltage) protection.The so-called loss-of-voltage and under-voltage protection means that when the power supply voltage drops too much or the power is temporarily cut off for some reason, the motor is automatically disconnected from the power supply; when the power supply voltage is restored, if the start button is not pressed again, the motor cannot start by itself.If the relay control is not used, but the knife switch is directly used for manual control, because the switch is not opened in time during the power failure, when the power supply voltage is restored, the motor will start by itself, which may cause an accident.In addition, there is an overvoltage relay, which is a relay that cuts off the power supply due to the suction of the electromagnet when the circuit voltage exceeds a certain value. It is used for overvoltage protection (such as protecting silicon tubes and thyristor components).
A voltage relay is an electronic control device, it has a control system (also known as an input loop) and a controlled system (also known as an output loop), usually used in automatic control circuits, it actually uses a smaller currentAn "automatic switch" to control larger currents.Therefore, it plays the role of automatic adjustment, safety protection, and conversion circuit in the circuit.Mainly used in relay protection devices of generators, transformers and transmission lines, as a starting element for overvoltage protection or low voltage blocking.Voltage relay is a measuring relay whose input quantity and characteristic quantity are voltage. It is divided into over-voltage relay and under-voltage relay.The former acts when the voltage value increases and reaches the set value, and then is in a post-acting state; the latter acts when the voltage value decreases and reaches the set value, and then is in a release state.Voltage relays include electromagnetic type and transistor type.
Shanghai Joseph Relay Division
边栏推荐
- Oracle中SQL语言和分页rownum分析
- 【HMS core】【Analytics Kit】【FAQ】如何解决华为分析付费分析中付款金额显示为0的问题?
- 梅科尔工作室-看鸿蒙设备开发实战笔记七——网络应用开发
- paging
- (BUG record) No module named PIL
- @RequestBody 和 @ResponseBody 详解
- 【HMS core】【FAQ】HMS Toolkit Typical Questions Collection 1
- 2022全球数字经济大会人工智能专场:AI安全受高度关注
- 干货|语义网、Web3.0、Web3、元宇宙这些概念还傻傻分不清楚?(中)
- Neural Network Study Notes 3 - LSTM Long Short-Term Memory Network
猜你喜欢
![【 HMS core 】 【 Analytics Kit] [FAQ] how to solve the payment amount in huawei pay analysis shows zero problem?](/img/f3/b9256fc04d1c9e15c74d2fc14db0fb.png)
【 HMS core 】 【 Analytics Kit] [FAQ] how to solve the payment amount in huawei pay analysis shows zero problem?

FPGA刷题——计数器(简易秒表、可置位计数器、加减计数器)

Selected System Design | Design of CAN Bus Controller Based on FPGA (with Code)

ESP32CAM 1838接收红外遥控器信号

Security Thought Project Summary

Linux内核设计与实现(十)| 页高速缓存和页回写

Verilog之数码管译码

鸿湖万联扬帆富设备开发板正式合入OpenHarmony主干

类和对象—6个默认成员函数

STM32CubeMX configuration to generate FreeRTOS project
随机推荐
ABP学习资源整理
电压继电器HDY-A/1-220VAC-1
Unity 锁定相机第二弹
2022全球数字经济大会人工智能专场:AI安全受高度关注
STM32F1读取MLX90632非接触式红外温度传感器
[HarmonyOS] [ARK UI] How to double-click the return key to exit in HarmonyOS ets language
TensorFlow自定义训练函数
简述controller,service,repository注解的用法(谈谈application.properties的作用)
Beyond Stream Processing !第四届实时计算 Flink 挑战赛启动,49 万奖金等你来拿!
Scrapy爬虫之网站图片爬取
spin lock和mutex使用场景的差异
类和对象—6个默认成员函数
Neural Ordinary Differential Equations
MFCC to audio, the effect should not be too funny >V
Alibaba Cloud OSS Object Storage
SQL language and paging rownum analysis in Oracle
The method of parameter passing
【云原生】-Docker安装部署分布式数据库 OceanBase
(BUG record) No module named PIL
Selected System Design | Design of CAN Bus Controller Based on FPGA (with Code)