当前位置:网站首页>Voltage relay h2d SRMUVS - 100 vac - 2
Voltage relay h2d SRMUVS - 100 vac - 2
2022-07-30 11:11:00 【Shanghai Joseph Electric Co., Ltd. Comprehensive operation】
Brand: Shanghai Joseph
Name: Undervoltage Monitoring Relay
Model:SRMUVS-100VAC-2Z
Power consumption≤5W
Contact capacity 250V5A
Rated voltage 58,100,110,220VAC
Series models:
SRMUVS-58VAC-2H under-voltage monitoring relay; SRMUVS-100VAC-2H under-voltage monitoring relay;
SRMUVS-110VAC-2H under-voltage monitoring relay; SRMUVS-220VAC-2H under-voltage monitoring relay;
SRMUVS-58VAC-2H2D under-voltage monitoring relay; SRMUVS-100VAC-2H2D under-voltage monitoring relay;
SRMUVS-110VAC-2H2D under-voltage monitoring relay; SRMUVS-220VAC-2H2D under-voltage monitoring relay;
SRMUVS-58VAC-4H under-voltage monitoring relay; SRMUVS-100VAC-4H under-voltage monitoring relay;
Purpose
SRMUVT series under-voltage monitoring relays are suitable for relay protection devices of generators, transformers and substation lines as starting elements for low-voltage blocking.(Applicable to AC 50/60HZ)
The set value and hysteresis return of the relay can be infinitely adjusted by the potentiometer
Technical parameters
Rated voltage: 58V 100V 110V 220V(AC)
Rated voltage range: 35%-130% rated voltage
Setting value: 50%-105% rated voltage
hysteresis return coefficient: 2%-20% relative to the set value
Scale error: ≤6%
Temperature error: ≤5W
Contact capacity: when the voltage is not greater than 250V; the long-term contact current is 5A; when the voltage is not greater than 250V; in a DC circuit with a circuit time constant L/R of 5MS, the contact breaking capacity is 50W;When the voltage is not more than 250V; in the AC circuit with a power factor COSφ of 0.4, the contact breaking capacity is 250VA
Dielectric strength: The relay can withstand 50HZ, 2KV between the terminals and the shell for 1 minute without breakdown or flashover
Ambient temperature: -25℃-55℃
Can be installed on U-shaped 35 rail
SRMUVT-100VAC-2Z;SRMUVS-220VAC-2H2D under-voltage monitoring relay model specifications
Undervoltage monitoring relay SRMUVT-100VAC-2Z;SRMUVS-220VAC-2H2D wiring diagram:
Dimensions
Voltage relay SRMUVS-100VAC-2H2D
Voltage relay
It is a relay that operates when the voltage in the circuit reaches a predetermined value.Its structure is basically the same as that of the current relay, but the number of turns of the electromagnet coil is many, and it should be connected in parallel with the power supply when used.It is widely used in voltage loss (zero voltage) and undervoltage (low voltage) protection.The so-called loss-of-voltage and under-voltage protection means that when the power supply voltage drops too much or the power is temporarily cut off for some reason, the motor is automatically disconnected from the power supply; when the power supply voltage is restored, if the start button is not pressed again, the motor cannot start by itself.If the relay control is not used, but the knife switch is directly used for manual control, because the switch is not opened in time during the power failure, when the power supply voltage is restored, the motor will start by itself, which may cause an accident.In addition, there is an overvoltage relay, which is a relay that cuts off the power supply due to the suction of the electromagnet when the circuit voltage exceeds a certain value. It is used for overvoltage protection (such as protecting silicon tubes and thyristor components).
A voltage relay is an electronic control device, it has a control system (also known as an input loop) and a controlled system (also known as an output loop), usually used in automatic control circuits, it actually uses a smaller currentAn "automatic switch" to control larger currents.Therefore, it plays the role of automatic adjustment, safety protection, and conversion circuit in the circuit.Mainly used in relay protection devices of generators, transformers and transmission lines, as a starting element for overvoltage protection or low voltage blocking.Voltage relay is a measuring relay whose input quantity and characteristic quantity are voltage. It is divided into over-voltage relay and under-voltage relay.The former acts when the voltage value increases and reaches the set value, and then is in a post-acting state; the latter acts when the voltage value decreases and reaches the set value, and then is in a release state.Voltage relays include electromagnetic type and transistor type.
Shanghai Joseph Relay Division
边栏推荐
猜你喜欢
实现web实时消息推送的7种方案
ESP32CAM 1838接收红外遥控器信号
Is it too late to apply for PMP now to take the September exam?Share agile full-true mock questions
[Qualcomm][Network] 网络拨号失败和netmgrd服务分析
Understanding of deadlock
系统设计精选 | 基于FPGA的CAN总线控制器的设计(附代码)
Neural Network Study Notes 3 - LSTM Long Short-Term Memory Network
优酷VIP会员周卡只需7.5元,看《沉香如屑》用优酷视频
神经网络学习笔记4——自动编码器(含稀疏,堆叠)(更新中)
电压继电器SRMUVS-100VAC-2H2D
随机推荐
mysql与redis 区别
unity3d C#语言基础(继承)
jmeter接口压力测试-(二)
拖放事件,dataTransfer,getBoundingClientRect
数据库脏读、不可重复读、幻读以及对应的隔离级别
【HMS core】【FAQ】HMS Toolkit典型问题合集1
Nacos configuration in the project of battle
干货|语义网、Web3.0、Web3、元宇宙这些概念还傻傻分不清楚?(中)
加密和安全
vscode中写markdown格式笔记的配置过程和相关语法
VLAN相关知识点
单片机开发之静态LED显示
张量篇-初步
STM32F1读取MLX90632非接触式红外温度传感器
log4js入门
Meikle Studio-Look at Hongmeng Device Development Practical Notes 7-Network Application Development
API 网关 APISIX 在Google Cloud T2A 和 T2D 的性能测试
AIX shell获取前几个月时间
Still using Swagger?I recommend this interface management artifact with zero code intrusion
【JZ64 求1+2+3+...+n】