Jhok-zbg2 leakage relay
2022-07-07 05:26:00 【Comprehensive operation of Shanghai Joseph Electric Appliance C】
brand :JOSEF Joseph
Product model :JHOK-ZBG1 20/5A 75/5
Action current :0.03mA~9.99A
Working voltage :AC220V/AC380V
Action time :0.02~99.99S
Installation mode : Guide rail in cabinet / Embedded panel
Zero sequence aperture :25mm~220mm
Host size :883660mm
The product name : Multi shift leakage ( The remaining ) Relay
One 、 Product overview
JHOK-ZBG series
Leakage relay ( Hereinafter referred to as relay ) Suitable for AC voltage to 660V Or higher TN、TT、 and IT System , The frequency is 50Hz. Detect the zero sequence current exceeding the setting value through the zero sequence current transformer ( The remaining ) Leakage current . The relay is connected with the circuit breaker of shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , Can be equipped with buzzer 、 Signal and other acoustooptic devices are combined to form a leakage alarm device . Derive multiple models , Prefix such as HLJ、RLJ、ULJ Series and other models , It is actually a similar product . It plays a very important role in the power system , It is the basis to ensure the reliability of power supply .
Two 、 Product use
The leakage protection relay has small volume 、 Easy to install and use 、 Reliable movement 、 Continuous power supply is stable and easy to operate . Can adapt to users everywhere , It can be used to protect the line from ground fault , It is mainly used to prevent equipment accident or electrical fire caused by grounding fault current , It can also be used to provide indirect contact protection for the release of human electric shock .
The leakage relay can be connected with the circuit breaker with shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , It can also be equipped with buzzer 、 Signal lamp and other acousto-optic devices are combined to form a leakage alarm device . With reset 、 instructions 、 Call the police 、 Reset and other functions .
It is not suitable for the central grounding point of power supply or direct grounding system 、 Low voltage distribution system . It is a network reform product for safe use . The action time of the relay is divided into fast type and delay type , When used together, the trunk line and branch line shall be protected by classification , It can completely replace the past LLJ-□F(S)、LLJ-□H(S)、JD1 And JD3 Series leakage relay .
3、 ... and 、 Product parameters
● Rating
Voltage rating : Rated voltage AC380V、AC660V、AC690V、AC1140V.
Working voltage value :DC24V、AC110V、AC127V、AC220V、AC380V. It can also be customized according to customer requirements .
Allowable variation range of power supply voltage : The voltage variation is the rated voltage 0.7 to 1.3 Times or wide power circuit .
Rated current value :16A、25A、32A、40A、63A、80A、100A、125A、200A、250A、320A、400A、630A、800A、1000A、1500A、1600A、2000A. Non standard point current can also be customized .
● Action value
Leakage action current : General or user-defined , Can also be 50-500mA Split gear or adjustable .
Leakage non action current : Half of the leakage action current .
Leakage action time : Delay type 0.2-2S.
Fast type ≤0.1S .
● Important parameter
The aperture of the transformer is round (L type ):M25、M45、M75、M100、M150、M160、M220.
Rectangular square ( Runway type ):45160、45220、45260、45320、45*450 etc. .
Four 、 working principle
The relay is an electronic current operated leakage relay , It is mainly composed of zero sequence current transformer 、 Electronic circuits 、 The working principle of the test circuit and outlet relay is as follows : The wiring is shown in the figure (1), Zero sequence transformer passing through the main line , When there is no leakage in the main line , The sum of vectors is equal to zero or minimal , When there is leakage or electric shock on the main line , The zero sequence transformer senses an unbalanced current vector and signal , When the circuit of zero sequence current transformer leaks to the ground iA+iB+iC≠0. Send it to the host for amplification , Check whether the leakage current exceeds the setting value , And send the results to the actuator for execution . At this time, the zero sequence current transformer will generate an induction signal , This signal is processed by electronic circuit , When the leakage current reaches the action value , Make the thyristor contact and make the relay act , Use relay normally open 、 The closing point controls the disconnection of the main circuit breaker or contactor , Cut off the fault line to achieve the purpose of protection . The test circuit is composed of resistors, buttons and other components , Press the test button , There is a current flowing through the transformer , Equivalent to the leakage current of the main line , The indicator light is on , The outlet relay should be able to act . Press the reset button , The light goes out , Outlet relay returns .
5、 ... and 、 Order needs to know
Rated current of the product 、 Leakage current 、 Transformer aperture . Rated voltage and working voltage . If delay is required , You have to specify the time .
JHOK-ZBG2 Leakage relay
1. Prevent electric shock accidents caused by leakage of electrical equipment and electrical lines ;
2. Prevent single-phase electric shock accidents during power use ;
3. Timely cut off the single-phase grounding electric shock fault in the operation of electrical equipment , Prevent fire accidents caused by electric leakage .
The working principle of leakage relay is as follows : Zero sequence transformer will pass through the main line , When there is no leakage in the main line , The sum of vectors will be equal to 0 Or very small . however , If there is leakage in the main line , The zero sequence transformer can sense that the vector sum is unbalanced , And the current vector will also send a signal to the zero sequence transformer , And send the signal to the host for amplification , We can check whether the leakage current exceeds the setting value , If the current exceeds the setting value , We can send the test results to the actuator , Let the actuator carry out maintenance, etc . Another way is , If the main line leaks electricity , The indicator light will be on , The outlet relay will also have a certain action and send a signal .
Shanghai Joseph relay business department
边栏推荐
猜你喜欢
If you‘re running pod install manually, make sure flutter pub get is executed first.
利用OPNET进行网络指定源组播(SSM)仿真的设计、配置及注意点
JHOK-ZBG2漏电继电器
拿到PMP认证带来什么改变?
Lombok插件
Use Zhiyun reader to translate statistical genetics books
c语言神经网络基本代码大全及其含义
Auto. JS get all app names of mobile phones
[opencv] image morphological operation opencv marks the positions of different connected domains
Is the human body sensor easy to use? How to use it? Which do you buy between aqara green rice and Xiaomi
随机推荐
利用OPNET进行网络单播(一服务器多客户端)仿真的设计、配置及注意点
np. random. Shuffle and np Use swapaxis or transfer with caution
【oracle】简单的日期时间的格式化与排序问题
Pytest testing framework -- data driven
利用OPNET进行网络仿真时网络层协议(以QoS为例)的使用、配置及注意点
SQL injection HTTP header injection
Harmonyos fourth training
Safe landing practice of software supply chain under salesforce containerized ISV scenario
Make web content editable
Full link voltage test: the dispute between shadow database and shadow table
JVM (XX) -- performance monitoring and tuning (I) -- Overview
Autowired注解用于List时的现象解析
2039: [蓝桥杯2022初赛] 李白打酒加强版 (动态规划)
拿到PMP认证带来什么改变?
Annotation初体验
[Oracle] simple date and time formatting and sorting problem
《4》 Form
HarmonyOS第四次培训
What changes will PMP certification bring?
AOSP ~binder communication principle (I) - Overview