[scheme design] scheme of household oximeter based on single chip microcomputer
2022-06-11 09:09:00 【Xicheng micro technology program development】
The oximeter is used to measure pulse rate 、 Instruments and equipment for blood oxygen concentration and perfusion index , Blood oxygen concentration is one of the important basic data in clinical medicine . If there are conditions , People should always monitor their oxygen saturation , It is more beneficial to your health . A scheme of household oximeter based on single chip microcomputer is introduced , The following is a detailed knowledge description .
One 、 Measuring principle of oximeter
The oximeter is based on the reduction of hemoglobin (Hb)、 Oxygenated hemoglobin (HbO2) The absorption spectrum characteristics in the red and near-infrared regions are the theoretical basis , Application LambertBeer Law establishes empirical formulas for data processing . The instrument adopts photoelectric blood oxygen detection technology combined with volume pulse tracing technology , Two beams of light with different wavelengths irradiate the fingertip of the human body through the perspective clip finger sensor, and the measurement signal is obtained by the photosensitive element , The obtained information is processed by the electronic circuit and microprocessor, and the measured results are displayed on the display screen .
Two 、 Technical characteristics of the oximeter
1、 Main performance of the oximeter
A. The blood oxygen saturation value is displayed
B. Pulse rate value 、 Bar graph display
C. Pulse waveform display
D. Battery level indication
E. Automatic shutdown function : After the tested finger is detached 8s Internal automatic shutdown
F. You can change the display direction , Depending on the display mode
2、 Main parameters of the oximeter
A. Blood oxygen saturation measurement range :35%~100% error : When the measurement range of blood oxygen saturation is 70%~100%, The allowable absolute error is ±2%; Less than 70% No definition .
B. Pulse rate measurement range :30bpm( Time /min)~250bpm( Time /min) error :±2bpm or ±2% Take a big value .
C. Display resolution : Blood oxygen saturation is 1%, Pulse rate is 1bpm.
D. The error of weak perfusion is 0.3% when , The oximeter can correctly display oxygen saturation and pulse rate , The error of blood oxygen saturation is ±3%; Pulse rate error is ±2bpm or ±2% Take a big value .( remarks : This indicator only refers to high-end oximeters , Weak perfusion degree of low-end oximeter >=1)
E. The anti ambient light interference ability compares the blood oxygen measurement value under indoor natural light and existing lighting sources with the measurement value under dark room conditions , The deviation is less than ±1%.
F. Working voltage :2.6VDC~3.0VDC It shall work normally .
G. Power waste :<30mA
3、 Features of oximeter products
Easy to use .
High precision , Low power consumption .
Small volume , Light weight , be easy to carry about .
边栏推荐
猜你喜欢

Matlab learning 7- linear smoothing filtering of image processing

openstack详解(二十四)——Neutron服务注册

Type-C扩展坞自适应供电专利维权案例

Vagrant mounting pit

CUMT学习日记——ucosII理论解析—任哲版教材
![[image processing] spatial domain image enhancement](/img/d9/6afee1006570651ccf93ed8da95dd3.png)
[image processing] spatial domain image enhancement

C language printing heart

Kubelet error getting node help

M1 chip guide: M1, M1 pro, M1 Max and M1 ultra

机器学习笔记 - 卷积神经网络备忘清单
随机推荐
83. delete duplicate elements in the sorting linked list
1854. 人口最多的年份
How to deal with these problems in the factory production process?
Comment l'entreprise planifie - t - elle la mise en oeuvre?
剑指 Offer II 041. 滑动窗口的平均值
Erreur de démarrage MySQL "BIND on TCP / IP Port: Address already in use"
C language printing heart
MSF给正常程序添加后门
【方案设计】基于单片机开发的家用血氧仪方案
Why is the string class final decorated
When the enterprise makes a decision, which part should lead the ERP project?
Pulsar job Plaza | Tencent, Huawei cloud, shrimp skin, Zhong'an insurance, streamnational and other hot jobs
445. 两数相加 II
20. valid brackets
Port occupancy problem, 10000 ports
SAP OData development tutorial
445. adding two numbers II
openstack详解(二十四)——Neutron服务注册
【软件】ERP体系价值最大化的十点技巧
矩阵求逆操作的复杂度分析(逆矩阵的复杂度分析)