当前位置:网站首页>Ankerui fire emergency lighting and evacuation indication system
Ankerui fire emergency lighting and evacuation indication system
2022-06-12 08:14:00 【acrelwc】
Encore Wang Chong
1. Project introduction
This project is a clean medicine research and innovation base , The project is located in Zhenjiang City, Jiangsu Province , Local monthly average temperature 31 Centigrade , The nature of the building is multi-storey industry ( Workshop ) Architecture ; Seismic intensity of buildings :7 degree ; Class a production workshop . Gross floor area 9552.2 Square meters , One corridor 178.74 Square meters , Four storey reinforced concrete frame building on the ground . Including complex building 、 Office building 、 Research and development center 、 Pharmaceutical Workshop 、 warehouse 、 Test center and other areas .
It is required that the centralized power supply and centralized control system shall be adopted for the emergency evacuation signs in the building , When a fire or emergency occurs , It can be reported by hand in the building 、 Smoke detection, etc. report the specific fire location , And transmit the command to the fire host of the system by means of communication , The arrow that controls the evacuation sign in the building points to , Ensure that personnel escape and evacuate in the right direction .
2. Introduction to field project application products
2.1 Fire emergency lighting and evacuation indication system
The fire emergency lighting and evacuation indication system is controlled by the controller ( host )、 Centralized power supply and lamps ( Evacuation indicating lamps 、 Emergency lighting fixtures ) Wait for several parts to make up . Only the main products are introduced here .
Generally, the emergency evacuation controller is called the host , Under normal conditions, the host can monitor the status of connected lamps in real time ; When there is a fire , The host can be linked with the automatic fire alarm controller , Call out the emergency escape routes for different fire alarm points from the database , Control different kinds of lamps to flash 、 turn on the light 、 Lights out 、 Change the direction of indication , Guide the personnel to escape along the escape route of the plan .
The centralized power supply is mainly the combination of the power distribution device and the standby power supply of the lamps , Set in the fire control room ; In case of fire, power shall be supplied to emergency evacuation lighting lamps and evacuation indicator lamps when the main power is cut off , Ensure the normal operation of emergency lighting and evacuation indication system .
Fire emergency lighting fixtures are mainly used in case of system emergency , Provide lighting for personnel evacuation . use DC36V The power supply is safe and reliable ,LED Low power consumption of lamp bead light source , Long service life , The controller can monitor the lamp status in real time .
The fire emergency sign lamp is mainly used when the system is in emergency , Provide directions for personnel evacuation . use DC36V The power supply is safe and reliable , green LED Energy saving and environmental protection of light source , The controller can control the direction of lamps and monitor the status of lamps .
2.3 A-D-0.5KVA-A200FP The technical parameters and product pictures of the centralized power supply are shown in the table below 2

surface 2
2.4 Lamps and lanterns
When there is a fire , Fire emergency sign lamps provide emergency evacuation direction for personnel , To the left 、 Right and two-way sign lamps are generally used to indicate the direction of evacuation , Directional sign lamps are generally used to indicate emergency exits 、 Floors and shelters . The installation method is wall mounted . This product is widely used in airports 、 Large shopping mall 、 Entrance and exit of safe passage in public places such as office buildings 、 At the corner of the corridor .

3.2 System diagram of site part
There is one set on site A-C-A100 controller 、 Multiple explosion-proof and high protection centralized power supplies 、 Multiple sets of lamps . The scheme adopted in this project is , Lamps and lanterns are usually connected to the centralized power supply by two buses , The centralized power supply to the controller of the piano stage is used CAN Bus .
3.3 System software operation interface
Main interface of system operation

Contains toolbars 、 Graphic display 、 Layer list 、 status bar , You can intuitively view the operation status of the monitoring equipment , And directly switch to the specific fault location according to the actual content of the status bar
Lamp configuration interface

You can view the status and quantity of all lamps
Event recording interface
You can view historical operations 、 Fault information , You can query by date
3.4 Photos of equipment field application

4. Conclusion
With the rapid development of China's economy , Progress in science and technology , The importance of building intelligence and building fire safety has also increased , This paper analyzes the A100 Application of fire emergency lighting and evacuation indication system in tunnel project , It fully demonstrates the simplicity in the networking of tunnel buildings 、 flexible 、 Stable 、 Low cost advantage . The fire emergency evacuation system can solve the problem that the traditional fire emergency evacuation indication system has no centralized control 、 The indication direction is fixed 、 The evacuation route cannot be changed 、 The indication effect is not ideal 、 Low safety performance .
Ankerui electric focuses on building products of various fire security systems , On the premise of meeting the requirements of national industrial standards , Provide intelligent services for all kinds of buildings 、 Energy saving 、 Cheap fire-fighting solutions and products , For fire prevention and disaster reduction 、 Make a contribution to ensuring the safety of people's lives and property !
reference
[1]. Product selection manual of ankerui Electric Co., Ltd .2018.01
[2].GB50116-2014 Code for fire protection design of buildings [S].
[3].GB17945-2010《 Fire emergency lighting and evacuation indication system 》[S].
[4].GB51309-2018《 Technical standard for fire emergency lighting and evacuation indication system 》[S].
边栏推荐
- N-order nonzero matrix AB, matrix ab=0, then the rank of a and B is less than n
- 电气火灾探测器对各用电回路进行实时监控
- Uni app screenshot with canvas and share friends
- Three data exchange modes: line exchange, message exchange and message packet exchange
- js中的数组
- 建立MES系统,需要注意什么?能给企业带来什么好处?
- System service configuration service - detailed version
- 802.11 protocol: wireless LAN protocol
- Upgrade eigen to version 3.3.5 under Ubuntu 16.04
- Strvec class mobile copy
猜你喜欢

Database connection pool and dbutils tool

DUF:Deep Video Super-Resolution Network Using Dynamic Upsampling Filters ...阅读笔记

FPGA generates 720p video clock

Map the world according to the data of each country (take the global epidemic as an example)

ctfshow web4

MATLAB image processing - cosine noise removal in image (with code)

余压监控系统保证火灾发生时消防疏散通道的通畅,为大型高层建筑的安全运行和人民生命财产安全保驾护航
![Easyexcel exports excel tables to the browser, and exports excel through postman test [introductory case]](/img/ca/0e2bd54a842a393231ec6db5ab02c2.png)
Easyexcel exports excel tables to the browser, and exports excel through postman test [introductory case]

Derivation of Poisson distribution

Explain the basic working principle of Ethernet
随机推荐
Hands on deep learning -- Introduction to linear regression model
MinGW offline installation package (free, fool)
Alibaba cloud deploys VMware and reports an error
vscode 下载慢解决办法
(P21-P24)统一的数据初始化方式:列表初始化、使用初始化列表初始化非聚合类型的对象、initializer_lisy模板类的使用
(P19-P20)委托构造函数(代理构造函数)和继承构造函数(使用using)
Principle and example of OpenMP task
MES系统是什么?MES系统的操作流程是怎样?
js中的正则表达式
OpenMP task 原理与实例
(p27-p32) callable object, callable object wrapper, callable object binder
企业上MES系统的驱动力来自哪里?选型又该注意哪些问题?
(P17-P18)通过using定义基础类型和函数指针别名,使用using和typedef给模板定义别名
A brief summary of C language printf output integer formatter
Leetcode notes: Weekly contest 277
智能制造的时代,企业如何进行数字化转型
How to write simple music program with MATLAB
ERP的生产管理与MES管理系统有什么差别?
Prediction of COVID-19 by RNN network
(P36-P39)右值和右值引用、右值引用的作用以及使用、未定引用类型的推导、右值引用的传递