RJ45 brief introduction 
chart 1 RJ45 modular
RJ45 Modules are used to implement PHY The interconnection between , Include PHY The chip is connected with RJ45 Interface connection , Pictured 1 Shown .
RJ45 The connector is composed of plug and socket ,RJ45 Plug is also called crystal head , Pictured 3-10 Shown . The connector composed of these two elements is connected between the wires , To achieve electrical continuity of the conductor .RJ45 The connector is the most important socket in the connector .RJ45 Sockets are divided into shielded and unshielded types .
RJ yes Registered Jack Abbreviation , intend “ Registered socket ”. stay FCC( FCC standards and regulations ) The definition in is ,RJ Is an interface that describes a public telecommunications network , Commonly used RJ-11 and RJ-45, Computer network RJ-45 It's a standard. 8 Bit modular interface .
chart 2 RJ45 Sockets and plugs
RJ45 Interface support 10M/100M/1000M Three rates , With sending and receiving & Polarity automatically flips ( unreliable )、 rate / Automatic negotiation function in duplex mode . Each rate mode has different implementation methods ( Corresponding to different agreements ),10M Patterns include 10BASE-T、10BASE2、10BASE5;100M Patterns include 100BASE-TX、100BASE-F;1000M The rate mode includes 1000BASE-T、1000BASE-F. What is commonly used is 10BASE-T、100BASE-TX、1000BASE-T Three .
10BASE-T use Manchester code , Two level signal , When working, two pairs of differential lines, one receiving and one sending , Transmission rate 10Mbps.
100BASE-TX Mode adoption 4B/5B code , efficiency 80%, Three level signal , Pictured 3-11 Shown . When working, two pairs of differential lines, one receiving and one sending , Transmission rate 125 MT/s, Because of the adoption of 4B/5B code , The actual transmission rate is 125MT/s×80% = 100Mbps.
chart 3 100M Pattern RJ45 Signal eye diagram
1000M Mode adoption 4D-PAM5 code , Five level signal , Pictured 3-12 Shown . So-called 4D-PAM5 Refer to 4 dimension 5 Level coding technology ,4 Dimension refers to 4 Two differential line pairs ,5 Level refers to the transmission of one on each differential line pair 5 Binary data , Therefore, each symbol can represent 54=625 Status , Corresponding to binary number ,29=512, Each symbol can represent a 9bit Binary number of , One of them is used to control , in addition 8 Bits are valid data . Because the symbol rate is also 125MT/s, Working hours 4 Send and receive the differential line at the same time , port Rx Adopt hybrid circuit (Hybrid) Filter out the same port Tx The signal ( Similar principle ADSL Hybrid circuit , use Tx Reverse the phase and then stack to eliminate the received Tx), So the actual The transmission rate is 125 MT/s×8bit = 1000Mbps.
chart 4 1000M Pattern RJ45 Signal eye diagram
Self negotiation technology
The earliest Ethernet networks were 10M Half duplex , So we need to CSMA/CD And a series of mechanisms to ensure the stability of the system . With the development of technology , There is full duplex , Then they appeared one after another 100M、1000M, The performance of Ethernet is greatly improved . But the question that follows is : How to ensure the compatibility between the original Ethernet and the new Ethernet ? therefore , Automatic negotiation technology came into being .
802.3 Section in the standard 28 This is how you define the auto negotiation function : It allows a device to inform the device at the far end of the link of its working mode , And detect the corresponding operation mode of remote notification . The purpose of automatic negotiation is to provide a way for two devices sharing a link to exchange information , And automatically configure them to work under the optimal capacity . therefore , Automatic negotiation is a way to achieve the maximum possible transmission rate between two devices . It allows the device to “ Discuss ” Possible transmission rate , Then choose the best rate acceptable to both parties . They use what are called fast link pulses FLP Exchange announcements of their respective transmission capabilities .FLP The opposite end can know the transmission capacity of the source end .
for example ,A and B Negotiating automatically , also A have 10/100/1000 Full half duplex capability , however B Only 10/100 Full half duplex capability , In this way, the maximum link capacity shared by both parties is 100, full duplex . Once both parties conduct automatic negotiation , The link will run under the best capability that both sides can support .
In order to ensure that the peer can connect even if it cannot support self negotiation , Introduced what is called parallel detection (Parallel Detection) The mechanism of . Open self negotiation at one end , When the other end closes self negotiation , The establishment of the connection depends on the parallel detection function . For the end of closing self negotiation , The port will continuously send signals ,10M、100M、1000M The signals sent are different , The end that supports automatic negotiation after receiving the opposite end signal , You can know what mode the opposite end is working in , If you also support this mode , Then it will establish a connection with the opposite end . But this connection can only be half duplex , Because the parallel detection cannot detect the duplex mode of the opposite end , Therefore, half duplex connection is adopted by default .
therefore , In automatic negotiation , If both sides support automatic negotiation , The result of negotiation establishes a maximum rate and duplex mode supported by both ends ; If one end forces one end to negotiate , Then only one half duplex connection can be established , The connection rate is the rate of forced mode ; If both ends work in forced mode , Only when the duplex mode of two forced modes is exactly the same , To establish an effective connection . Pictured 5 Shown .
chart 5 Three automatic negotiation results
RJ45 Circuit design
1、RJ45 Line sequence of interface
From the signal transformer of Ethernet port TX-/TX+、RX-/RX+ Signals and RJ45 The connection must conform to RJ45 The interface specification , Pictured 3-14、 chart 3-15 Shown . The specific requirements are as follows :
1) The polarity should be correct , It must not be reversed , Although some chips support polarity reversal , But when the chips of different schemes cooperate , Sometimes things go wrong .
2) Send and receive correctly , You must not reverse , Although the current chip design plays down the position of the transceiver pair , But in order not to take risks , Unless cabling cannot be achieved , Or do not reverse the wiring according to the regulations .
chart 6 10BASE-T/100BASE-TX Linear sequence
Detailed polarity and transceiver connection regulations are as follows :
100M Card terminals ( Corresponding to general routers WAN mouth )RJ45 Interface :1-TX+、2-TX-;3-RX+、6-RX-;
100M Switch ( Corresponding to general routers LAN mouth )RJ45 Interface :1-RX+、2-RX-;3-TX+、6-TX-;
1000M RJ45 Interface :1-DA+、2-DA-;3-DB+、6-DB-;4-DC+、5-DC-;7-DD+、8-DD-; or :1-DB+、2-DB-;3-DB+、6-DB-;4-DD+、5-DD-;7-DC+、8-DC-;
chart 6 1000BASE-T Linear sequence
2、PCB Layout matters needing attention
PHY To the signal transformer is differential wiring , Difference is needed 100 Ohmic impedance control . The routing requires that the differential pair of two lines should be as long as possible , The difference line is equidistant , Try to complete the package .
RJ45 Network cable
Internationally recognized network cable standards are divided into seven categories , At present, five categories are commonly used 、 CAT5 and CAT6 twisted pair , Pictured 3-19 Shown . All three are composed of four pairs of twisted pairs , The difference lies in , The super category 5 network cable increases the winding density compared with category 5 network cable , Thus, the crosstalk is smaller , The transmission distance is longer , Larger transmission bandwidth . And category 6 network cable increases the diameter of cable on super category 5 network cable , And an insulating cross frame is added in the middle of the network cable , Place four pairs of twisted pairs on the four grooves of the cross frame , Further improve the signal-to-noise ratio .
Category 5 network cable is suitable for 100 Gigabit Ethernet , Cat 5 and Cat 6 network cables are suitable for Gigabit Ethernet . Of course, in short distance transmission , There will be no problem using category 5 network cables for Gigabit Ethernet connections .
The production standards of network cable mainly include T568-A and T568-B Two kinds of ,T568-A The line order of is : Green and white 、 green 、 Orange white 、 blue 、 Bluish white 、 orange 、 Brown and white 、 Brown .T-568B The line order of is : White orange 、 orange 、 white green 、 blue 、 White and blue 、 green 、 White brown 、 Brown , Pictured 7 Shown .
At present, it is widely used T568-B Standard line sequence .
chart 7 RJ45 Plug and socket wire sequence
There are two types of network cable connection: straight through and cross , Straight line means that the line sequence at both ends of the network line is the same , A fellow T568A Standard or T568B standard , The straight line is used to connect two interfaces with different properties , Such as PC to Switch/Hub,Router to Switch/Hub etc. ; Cross line means that the line sequence at both ends of the network line is different , At one end T568A standard , The other end is T568B standard , The cross line is used to connect two ports with the same properties, such as Switch to Switch,Switch to Hub, Hub to Hub, Host to Host,Host to Router etc. . It's generally understood that : Use cross wire connection between the same type of equipment , Different types of equipment are connected by straight lines , Routers and PC Belong to DTE( Data terminal equipment ) Type of equipment , Switch and HUB Belong to DCE( Data communication equipment ) Type of equipment .
边栏推荐
- USB Type-C 详解
- 食品安全 | 面包含盐量也会超标?几招教你正确吃面包!
- LeetCode79题 方法一:深度搜索
- Ren Zhengfei's latest voice: American politicians hope Huawei will die, and the desire to survive inspires Huawei
- The revenue of Shanghai silicon industry in the first half of the year was 850million yuan, an increase of 30.53% year on year! Various product certifications are accelerating
- Mysql操作大全
- There is a special cryptology language called asn.1
- Nearly 200000 people watched a live calligraphy video
- busybox最新版(busybox apk)
- Cloud container and cloud native
猜你喜欢

示波器参数详解

Digital filter (IV) -- converting analog filter into digital filter

The best implementation of horizontal listview -- recycleview

Digital filter (II) -- minimum phase delay system and all pass system

Flutter:异常处理

Digital filter (VI) -- design FIR filter

矢量网络分析仪(矢网)的校准

Internet intelligence, how to define the next generation network transformation

Leetcode--45. jumping game II (greed)

TCP/IP详细图解
随机推荐
【译】创意编码之噪音
Outdoor activities in hot weather are exquisite! Here comes the safety guide for citizens' fitness in midsummer
Iptables防火墙详细介绍
Personal production: ad library, component library, packaging library and 3D model, free of charge
有一种密码学专用语言叫做ASN.1
Mongodb initialization operation
频谱仪原理简介二
Import the database backup of MySQL 8 into MySQL 5
天线的原理、分类及要求
Answer questions about the pixel, resolution and size of the picture, as well as the display size of the monitor.
业绩增长强劲!闻泰科技上半年净利17亿元,同比暴增767.19%!
Go的sleep
频谱分析仪的性能参数
联发科已向美方提交申请,力求9月15日后仍可向华为供货
2023年网络安全预算规划的五个关键考虑因素
VSC writes go, expected 'package' appears, found 'EOF‘
ModelBox端云协同AI开发套件(RK3568)试用记录(三)
计算机组成原理核心知识点总结&面试笔试要点[通俗易懂]
The diversion between video number and official account is convenient and considerable
MongoDB创建索引