当前位置:网站首页>Online monitoring of UPS power supply and operating environment in the computer room, the solution is here
Online monitoring of UPS power supply and operating environment in the computer room, the solution is here
2022-08-03 18:09:00 【Completion Technology】
I. Background of the scheme:
A company's computer room operation and maintenance personnel contacted us through the network, hoping to monitor the UPS power supply and operating environment in the computer room online to prevent changes in the temperature and humidity in the computer room and affect the normal operation of the computer room.Therefore, it is required to form a set of information-based and intelligent monitoring and management of UPS power supply, temperature and humidity, smoke sensor, water leakage, mains electricity, door sensor, etc. in the computer room.The way to make timely alarm notification for abnormal situation.

User Challenges:
a. The abnormal mains power causes the instability of the power supply system, which affects the power supply of the equipment and affects the normal operation of the equipment room.
b. It is impossible to control the real-time operating status of the UPS power supply.
c. It is impossible to control the changes of the computer room environment, which is easy to cause failures.
d. It is difficult and expensive to manually guard the computer room 24 hours a day.
e. There is a lack of early warning and fault alarm notification. If someone illegally invades, it is impossible to know.
Second, the solution:
According to the user's requirements and the general situation of the computer room, in order to ensure the efficient operation, maintenance and management of the UPS power supply and its operating environment in the user's computer room, the 4G full Netcom's Junda computer room environment cloud monitoring terminal is selected.An integrated multi-mode monitoring and alerting solution.Users can intuitively read the battery status, load, mains status, fault status and other data of the UPS, as well as the operating status of the computer room environment through the computer terminal and the mobile phone terminal.In case of abnormal situations such as mains power outage and ambient temperature and humidity exceeding the upper limit, immediate alarms will be sent through local sound and light, text messages, telephone voice, WeChat, etc., so that users can take corresponding measures in time.

Three, technical features:
1. Support most brands of UPS protocols on the market, and accept manufacturers' customized protocols.
2. Support email, short message, telephone voice, WeChat and other alarm methods to notify users of equipment abnormalities in time.
3. It supports setting up to 8 users. In case of abnormal situations, the alarm information can be sent to the mobile phones of (up to) 8 administrators at the same time.The call reminder function can also be enabled, and the user can receive the alarm information of the device at the first time.
4. The monitoring host has a built-in lithium battery, which can also work on standby for 30 minutes when the external power supply is disconnected.
5. Support a variety of secondary development interfaces, including HTTP XML data exchange, SNMP, database interface, etc.
6. Support snmp: V1, V2, V3.
7. Support one independent RS485 expansion interface, which can expand the temperature and humidity detection unit (up to 8 expansion).
8. Supports water leakage (water immersion) detection (external water leakage sensor is required).
9. Support fire smoke detection (external smoke sensor is required).
10. Support infrared
11. Support door sensor (open door) detection (external door sensor sensor is required).
12. Supports mains input status detection (requires an external mains unit).
13. Support air conditioner remote control function (optional, external air conditioner controller is required).
Four. Interface display:
(1) Computer web page: In the monitoring center, the user administrator can log in to the management interface through a compatible browser such as IE, Chrome, 360, etc. on the computer, and view the inverter,Real-time monitoring of the operating status of the battery, bypass, load and other components, and real-time monitoring of various voltage, current, frequency, power and other parameters of the UPS, as well as the real-time status of ambient temperature and humidity, smoke, water leakage or other switching quantities.Once an abnormality is detected, alarm notifications such as telephone voice, text message, local sound and light, etc. will be sent immediately, and detailed alarm records will be kept.

(2.) Mobile phone WeChat management interface: The device name can be named for easy management, and there is a corresponding display interface, such as: running status, alarm information, etc.Users can view the operating status of the inverter, battery, bypass, load and other components of the UPS power supply in real time through mobile phone WeChat, and monitor various voltage, current, frequency, power and other parameters of the UPS in real time, as well as the ambient temperature and humidity., real-time status of smoke, water leakage or other switching quantities.Once there is an abnormal situation, WeChat will receive the push of the alarm information.

V. Scheme configuration:
1. Junda computer room environment cloud monitoring terminal (4G)
A monitoring product that supports 4G full Netcom (Telecom, China Mobile, China Unicom) based on UPS room environment.It can support monitoring 1-way UPS, up to 5-way sensor input interface and 3-way remote control output interface.It can be equipped with a temperature and humidity detection unit to monitor the temperature and humidity in the equipment room in real time.It has a WEB page to remotely view the real-time running status of each monitoring device (UPS, temperature and humidity, smoke detector, water leakage, etc.)For example, the mains is interrupted, the battery voltage is low and other abnormal situations.(Users need to provide a mobile phone card)

2. Temperature and humidity and other switching modules (smoke, water leakage, infrared, sound and light, etc.)

边栏推荐
- 爬虫之selenium
- WebGL管网展示(及TubeGeometry优化)
- TiFlash 计算层概览
- 走进通信:为什么4G信号满格,却上不了网呢
- pydev debugger: warning: trying to add breakpoint to file that does not exist: /tmp/xxx
- 新“妖股”13个交易日暴涨320倍,市值3100亿美元超阿里
- Execution plan of mysql
- 七夕
- 大佬,谁有空帮忙看下这个什么问题呢,我就读取MySQLsource print下,刚接触flink,
- fatal error: jni.h: No such file or directory
猜你喜欢

WebGL管网展示(及TubeGeometry优化)

基于PHP7.2+MySQL5.7的回收租凭系统

Cool open technology x StarRocks: unified OLAP analysis engine, comprehensive building digital model of OTT

Is OnePlus Ace worth buying?Use strength to interpret the power of performance

细胞不可渗透的荧光探针 锌离子荧光探针Zinquin 151606-29-0

云渲染的优势与劣势

gcc的学习及 版本太低如何在conda环境下重新进行安装

多肽介导PEG磷脂——靶向功能材料之DSPE-PEG-RGD/TAT/NGR/APRPG

走进通信:为什么4G信号满格,却上不了网呢

Execution plan of mysql
随机推荐
LyScript 内存交换与差异对比
gcc的学习及 版本太低如何在conda环境下重新进行安装
How to install and start VNC remote desktop service on cloud GPU?
rhel8.3 系统下修改有线网卡配置信息实现联网
Jenkins CI平台(二)
七夕
云GPU如何安装和启动VNC远程桌面服务?
宝塔搭建企业招聘网站源码实测
Digital IC Handwriting - MCMM, WNS and TNS
Mock模拟数据,并发起get,post请求(保姆级教程,一定能成功)
DataWorks 标准版怎样实现SQL代码的复用?
云渲染的优势与劣势
openresty 高可用部署
STM32——LCD—FSMC原理简介
ICDAR competition technology sharing
爬虫之selenium
云图说丨初识华为云微服务引擎CSE
架构基本概念和架构本质
这是Facebook母公司 关于元宇宙的80万亿美元豪赌
Weekly recommended short video: In order to fill the gap of learning resources, the author specially wrote a book?