当前位置:网站首页>Smart construction site "hydropower energy consumption online monitoring system"
Smart construction site "hydropower energy consumption online monitoring system"
2022-07-05 05:39:00 【HZZD_ HZZD】
In order to achieve “ Saving energy and reducing consumption “、“ water saving ” Overall goal of , Complete the concept of green development in urban and rural construction planning , In the latest version 《 Evaluation standard for green construction of construction engineering 》、《 Civilized construction standards for construction projects 》 And its region 《 Green construction site creation standard 》 in , It is clear that “ The consumption of energy consumption of resources such as production, manufacturing and domestic electricity at the construction site should be subject to sub project measurement management . engineering construction 、 daily life 、 Office water should be measured separately by items .” Smart construction site “ Online monitoring system of hydropower energy consumption ” It has the function of real-time monitoring and statistics of hydropower energy consumption , Is to complete energy consumption “ Measured by items ” The main key technologies of , More and more attention has been paid by the construction industry .
Complete the intelligent meter reading according to the intelligent water and electricity meter , Real-time monitoring , Show the trend of hydropower consumption with a curve . Quantitative analysis of budget quota allocation of energy , Abnormal resolution occurs , Automatic warning information , Historical time data analysis and statistics . It can accurately calculate the energy consumption of hydropower ; Comprehensively grasp the water and electricity consumption of the project , Avoid waste of resources .
The real-time monitoring of energy consumption of water and electricity meters has great influence on the system construction water 、 electric 、 Data collection and analysis of gas and kinetic energy , And get the corresponding energy-saving countermeasures . Carry out remote monitoring of the total power consumption of the watt hour meter at the outlet of each low-voltage Group , Carry out remote monitoring and measurement of water supply pipelines , The meter reading data directly enters the service platform through the equipment network for analysis and solution , Complete the energy consumption quota of the construction site , Include the energy-saving quota index value in the contract text to carry out measurement and evaluation .
The system software is provided by the energy consumption management server 、 Data collector 、 Multi function electricity meter and wireless remote water meter , according to RS485 The computer interface carries out the on-site networking scheme , Energy consumption data is based on TCP/IP The network is transmitted to the energy consumption management server for statistics and display , At the same time, it has a socket to expand the data core of superior leaders , It realizes the intellectualization of energy consumption management on the construction site .
Smart construction site “ Functions of online monitoring system for hydropower energy consumption “
(1) It can be selected independently and must be queried at the same time 、 The range of analysis or various data of the loop , And generate corresponding tables and graphs . The historical time curve can gradually expand the time range at will , It is helpful to analyze the reasons in detail when the data is abnormal .
(2) According to statistics, water 、 Total consumption of electric energy consumption , Carry out sub items 、 Partition 、 Total energy consumption of classified energy consumption 、 Year on year 、 Month on month cross statistics , year 、 month 、 Japan 、 Total energy consumption 、 Trend change analysis of itemized energy consumption .
(3) Energy consumption unit consumption analysis , Select the type and time range of energy consumption to carry out year-on-year comparison of daily unit consumption of electronic computers , Comparative analysis shows . Energy consumption analysis of main equipment , Select energy consumption and loss data of multiple key equipment , Select a time range to carry out the change trend and display of equipment energy consumption .
(4) Energy consumption monitoring data can be exported at the same time , It can be stored in the data server for many years .
(5) System integration real-time monitoring , Including real-time data of system software 、 Historical time data, etc ; The interface should be real-time 、 Dynamically 、 Directly indicate the data at the collection point .
(6) The system can complete the storage system and statistical analysis of historical time data , Japan / month / season / Formation of annual financial statements 、 Data backup data 、 Functions such as system software log and user authority management .
(7) Data details 、 The data file directory meets the requirements of Party A , Data details should be given with detailed address 、 Data types 、 Enterprise and other information . The system software needs to provide the hardware configuration of communication 、 software interface 、 Ensure that the data can be safely sent to the smart construction site “ Online monitoring system of hydropower energy consumption “.
边栏推荐
- Yolov5 adds attention mechanism
- Wazuh开源主机安全解决方案的简介与使用体验
- Using HashMap to realize simple cache
- How can the Solon framework easily obtain the response time of each request?
- Sword finger offer 04 Search in two-dimensional array
- Light a light with stm32
- 读者写者模型
- Yolov5 ajouter un mécanisme d'attention
- Zzulioj 1673: b: clever characters???
- Talking about JVM (frequent interview)
猜你喜欢
2017 USP Try-outs C. Coprimes
[jailhouse article] look mum, no VM exits
全排列的代码 (递归写法)
A misunderstanding about the console window
剑指 Offer 35.复杂链表的复制
【Jailhouse 文章】Jailhouse Hypervisor
shared_ Repeated release heap object of PTR hidden danger
游戏商城毕业设计
Yolov5 ajouter un mécanisme d'attention
剑指 Offer 53 - II. 0~n-1中缺失的数字
随机推荐
卷积神经网络——卷积层
Using HashMap to realize simple cache
Improvement of pointnet++
Graduation project of game mall
Implement a fixed capacity stack
网络工程师考核的一些常见的问题:WLAN、BGP、交换机
Simply sort out the types of sockets
Educational Codeforces Round 107 (Rated for Div. 2) E. Colorings and Dominoes
Acwing 4300. Two operations
Pointnet++ learning
剑指 Offer 05. 替换空格
剑指 Offer 05. 替换空格
On-off and on-off of quality system construction
每日一题-无重复字符的最长子串
智慧工地“水电能耗在线监测系统”
A new micro ORM open source framework
kubeadm系列-00-overview
Service fusing hystrix
剑指 Offer 35.复杂链表的复制
【Jailhouse 文章】Look Mum, no VM Exits