当前位置:网站首页>Dj-zbs2 leakage relay
Dj-zbs2 leakage relay
2022-07-07 05:26:00 【Comprehensive operation of Shanghai Joseph Electric Appliance C】
Series models :
DJ-ZBS1 Two shift leakage ( The remaining ) Relay
DJ-ZBS2 Two shift leakage ( The remaining ) Relay
DJ-ZBS3 Two shift leakage ( The remaining ) Relay
DJ-ZBS The leakage relay was originally a split fixed installation , In order to meet the needs of current installation occasions , Shanghai Joseph relay factory in the original product DJ Product upgrade based on leakage relay , The development appears in the more popular separate guide rail installation DJ Leakage relay , It is widely used in coal mines and other places , It is also a coal mine leakage relay ; Small volume 、 Easy to install and use 、 Reliable movement 、 Continuous power supply is stable and easy to operate . Can adapt to users everywhere , It can be used to protect the line from ground fault , It is mainly used to prevent equipment accident or electrical fire caused by grounding fault current , It can also be used to provide indirect contact protection for the release of human electric shock .
One 、 Product overview
Integrated leakage relay ( Hereinafter referred to as relay ) Suitable for AC voltage to 660V Or higher TN、TT、 and IT System , The frequency is 50Hz. Detect the zero sequence current exceeding the setting value through the zero sequence current transformer ( The remaining ) Leakage current . The relay is connected with the circuit breaker of shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , Can be equipped with buzzer 、 Signal and other acoustooptic devices are combined to form a leakage alarm device . Derive multiple models , Prefix such as HLJ、RLJ、ULJ Series and other models , It is actually a similar product . It plays a very important role in the power system , It is the basis to ensure the reliability of power supply .
Two 、 Product use
The leakage protection relay has small volume 、 Easy to install and use 、 Reliable movement 、 Continuous power supply is stable and easy to operate . Can adapt to users everywhere , It can be used to protect the line from ground fault , It is mainly used to prevent equipment accident or electrical fire caused by grounding fault current , It can also be used to provide indirect contact protection for the release of human electric shock .
The leakage relay can be connected with the circuit breaker with shunt release or voltage loss release 、 AC contactor 、 Magnetic starter and other components of leakage protection device , For leakage and electric shock protection , It can also be equipped with buzzer 、 Signal lamp and other acousto-optic devices are combined to form a leakage alarm device . With reset 、 instructions 、 Call the police 、 Reset and other functions .
It is not suitable for the central grounding point of power supply or direct grounding system 、 Low voltage distribution system . It is a new product of network reform for safe use . The action time of the relay is divided into fast type and delay type , When used together, the trunk line and branch line shall be protected by classification , It can completely replace the past LLJ-□F(S)、LLJ-□H(S)、JD1 And JD3 Series leakage relay .
3、 ... and 、 Product parameters
● Rating
Voltage rating : Rated voltage AC380V、AC660V、AC690V、AC1140V.
Working voltage value :DC24V、AC110V、AC127V、AC220V、AC380V. It can also be customized according to customer requirements .
Allowable variation range of power supply voltage : The voltage variation is the rated voltage 0.7 to 1.3 Times or wide power circuit .
Rated current value :16A、25A、32A、40A、63A、80A、100A、125A、200A、250A、320A、400A、630A、800A、1000A、1500A、1600A、2000A. Non standard point current can also be customized .
● Action value
Leakage action current : General or user-defined , Can also be 50-500mA Split gear or adjustable .
Leakage non action current : Half of the leakage action current .
Leakage action time : Delay type 0.2-2S.
Fast type ≤0.1S .
● Important parameter
The aperture of the transformer is round (L type ):M25、M45、M75、M100、M150、M160、M220.
Rectangular square ( Runway type ):45160、45220、45260、45320、45*450 etc. .
Output contact form : Open and close .
● Other parameters
Contact capacity : The output contact of the relay can be disconnected no more than 250V, The time constant is 5±0.75mS The DC inductive load circuit of is 50W; The voltage is not greater than 250V The AC circuit of is 50VA. The relay can be switched on for a long time 5A.
Power consumption : Not more than... Under rated voltage 5W.
ambient temperature :-10℃~+50℃.
Medium strength The conductive terminals of the relay are connected together between the exposed non live metal parts or shells , Able to bear 2000V( Valid values ) AC voltage , after 1 Minutes test without insulation breakdown or flashover .
Insulation resistance : The conductive terminals of the relay are connected together between the exposed non-metallic part and the shell , Use open circuit voltage 500V The insulation resistance measured by the megger of is not greater than 300MΩ.
Electrical life : The relay contact is connected to the circuit load of the specified capacity , The electric life is 100000 Time .
Four 、 working principle
The relay is an electronic current operated leakage relay , It is mainly composed of zero sequence current transformer 、 Electronic circuits 、 The working principle of the test circuit and outlet relay is as follows : The wiring is shown in the figure (1), Zero sequence transformer passing through the main line , When there is no leakage in the main line , The sum of vectors is equal to zero or minimal , When there is leakage or electric shock on the main line , The zero sequence transformer senses an unbalanced current vector and signal , When the circuit of zero sequence current transformer leaks to the ground iA+iB+iC≠0. Send it to the host for amplification , Check whether the leakage current exceeds the setting value , And send the results to the actuator for execution . At this time, the zero sequence current transformer will generate an induction signal , This signal is processed by electronic circuit , When the leakage current reaches the action value , Make the thyristor contact and make the relay act , Use relay normally open 、 The closing point controls the disconnection of the main circuit breaker or contactor , Cut off the fault line to achieve the purpose of protection . The test circuit is composed of resistors, buttons and other components , Press the test button , There is a current flowing through the transformer , Equivalent to the leakage current of the main line , The indicator light is on , The outlet relay should be able to act . Press the reset button , The light goes out , Outlet relay returns .
DJ-ZBS2 Leakage relay
1. Prevent electric shock accidents caused by leakage of electrical equipment and electrical lines ;
2. Prevent single-phase electric shock accidents during power use ;
3. Timely cut off the single-phase grounding electric shock fault in the operation of electrical equipment , Prevent fire accidents caused by electric leakage .
Shanghai Joseph relay business department
边栏推荐
- LabVIEW is opening a new reference, indicating that the memory is full
- Egr-20uscm ground fault relay
- Dbsync adds support for mongodb and ES
- Talk about mvcc multi version concurrency controller?
- Aidl and service
- Leetcode (46) - Full Permutation
- 基于 hugging face 预训练模型的实体识别智能标注方案:生成doccano要求json格式
- 一条 update 语句的生命经历
- The sooner you understand the four rules of life, the more blessed you will be
- Vector and class copy constructors
猜你喜欢
Design, configuration and points for attention of network unicast (one server, multiple clients) simulation using OPNET
window定时计划任务
JVM(十九) -- 字节码与类的加载(四) -- 再谈类的加载器
Harmonyos fourth training
【js组件】date日期显示。
SQL injection cookie injection
数字化如何影响工作流程自动化
A cool "ghost" console tool
利用OPNET进行网络单播(一服务器多客户端)仿真的设计、配置及注意点
【js组件】自定义select
随机推荐
window定时计划任务
Autowired注解用于List时的现象解析
数字化创新驱动指南
利用OPNET进行网络任意源组播(ASM)仿真的设计、配置及注意点
Window scheduled tasks
JVM (19) -- bytecode and class loading (4) -- talk about class loader again
SQL injection HTTP header injection
Linkedblockingqueue source code analysis - initialization
np. random. Shuffle and np Use swapaxis or transfer with caution
在米家、欧瑞博、苹果HomeKit趋势下,智汀如何从中脱颖而出?
PMP证书有没有必要续期?
Tencent cloud database public cloud market ranks top 2!
The founder has a debt of 1billion. Let's start the class. Is it about to "end the class"?
Scheduledexecutorservice timer
pytest测试框架——数据驱动
JHOK-ZBG2漏电继电器
DFS, BFS and traversal search of Graphs
Complete code of C language neural network and its meaning
利用OPNET进行网络仿真时网络层协议(以QoS为例)的使用、配置及注意点
How can professional people find background music materials when doing we media video clips?