I. Introduction to the working principle
In general, the industrial two-way mixed-signal wireless transmitter DTD122FH consists of a transmitter and a receiver.The transmitting terminal simultaneously collects standard 4-20mA current signal and switch signal, and transmits it through full digital wireless mode.It can enter display instruments, warning lights, PLC or DCS and other equipment and drive industrial equipment such as solenoid valves and frequency converters.
At present, industrial-grade long-distance wireless transmission devices have been widely used in complex and harsh industrial occasions such as cement, smelting, power generation, coal, chemical industry, etc. The functions that can be realized are:Start and stop of water pump; wireless communication between local control station and PLC of large mobile machines such as stacker-reclaimer and unloader;Wireless control of car dust removal system.

Second, parameters and performance
◆ It can directly replace the wired cable to realize long-distance wireless acquisition and transmission of analog or switch value
◆ 4-16 channels of 4-20mA analog signal or 0~5V voltage signal input and output
◆ 4-16 switch input and output channels
◆ It can realize point-to-point communication, and it is also suitable for point-to-multipoint and inconvenient ditching and wiring applications.
◆ No need to write a program, it can be used simply by wiring; no card is inserted, no traffic
◆ There are 4 options for effective wireless transmission distance: 200m, 1km, 3km, 20km
◆ DC voltage 9-24V power supply, the average working current is less than 50mA
◆ PVC plastic shell, E-type guide rail slot installation, rain-proof metal chassis for long distances
◆ 20 years of industrial field operation test to ensure long-term operation in various harsh industrial environments
◆ Low power consumption, which can save a lot of electricity and equipment maintenance costs for enterprises every year
Three, application scenarios
Application scenario 1: Wireless monitoring of hot blast valve and boiler liquid level of waste heat power generation system
In the waste heat power generation system, the DCS system in the control room needs to monitor the temperature and pressure of the boiler and sub-system equipment in real time, and remotely control the valve position switch of the cement line hot air valve through wireless means.Because the sensor data to be collected is scattered and the distance is different, the system designer believes that it is easier to transform by using wireless transmission.The wireless mixed signal transmitter DTD120FHC is installed in the DCS system to transmit the collected analog data to the DCS system. After the DCS system processes the data, it outputs the control signal for the valve position switch of the hot blast valve.

Application scenario 2: wireless communication system between coke cart and ground dust removal station
Because the coke pusher is a mobile device, it is inconvenient for wiring, so the two coke pushers in the dust removal control system, the ground dust removal station, the fan start and stop, high and low speed feedback signals and the coke pusher walkingThe signal establishes communication wirelessly, thus replacing the manual walkie-talkie and manual control.In detail, the bidirectional mixed-signal wireless transmission device DTD122FHEY can be used to meet the requirements.

The driver of the coke pusher can receive the fan speed from the coke pusher monitoring room.When the dust removal operation is required, a high-speed fan operation request is issued to the central control room, and the central control room PLC determines whether to execute it. After the fan is running at a high speed, the high-speed signal is fed back to the two coke pushers.The command light changes.This not only solves the problem of communication between the coke pusher and the dust removal fan, but also solves the problem of dust removal coordination between the two coke pushers, which improves the safety and timeliness of operation.
边栏推荐
- burp安装及代理设置
- pyqt5 + socket 实现客户端A经socket服务器中转后主动向客户端B发送文件
- 多御安全浏览器新版下载 | 功能优秀性能出众
- [MRCTF2020]PYWebsite
- Queue Topic: Recent Requests
- presto启动成功后出现2022-08-04T17:50:58.296+0800 ERROR Announcer-3 io.airlift.discovery.client.Announcer
- Hard power or soft power, which is more important to testers?
- Qixi Festival code confession
- UE4 通过互动(键盘按键)开门
- Android实战开发-Kotlin教程(入门篇-登录功能实现 3.3)
猜你喜欢
![[GYCTF2020]EasyThinking](/img/40/973411c69d1e4766d22f6a4a7c7c01.png)
[GYCTF2020]EasyThinking

冰蝎V4.0攻击来袭,安全狗产品可全面检测

UE4 opens door via interaction (keyboard key)

银行数据采集,数据补录与指标管理3大问题如何解决?

用Unity发布APP到Hololens2无坑教程

Detailed and comprehensive postman interface testing practical tutorial

UE4 通过重叠事件开启门

Use CH341A to program external Flash (W25Q16JV)

程序开发的一些常规套路(一)

运维监控系统之Open-Falcon
随机推荐
七夕节代码表白
burp安装及代理设置
[TA-Frost Wolf_may-"Hundred Talents Project"] Graphics 4.3 Real-time Shadow Introduction
You may use special comments to disable some warnings. 报错解决的三种方式
Call Alibaba Cloud oss and sms services
[BSidesCF 2019]Kookie
ffmpeg -sources分析
[MRCTF2020]PYWebsite
UI自动化测试 App的WebView页面中,当搜索栏无搜索按钮时处理方法
Bosses, I noticed that a mysql CDC connector parameters scan. The incremental. Sna
Hard power or soft power, which is more important to testers?
工业级远距离无线传输装置的功能有哪些?
多御安全浏览器 V10.8.3.1 版正式发布,优化多项内容
[SWPU2019]Web1
Spark基础【介绍、入门WordCount案例】
UE4 后期处理体积 (角色受到伤害场景颜色变淡案例)
Based on holding YOLOv5 custom implementation of FacePose YOLO structure interpretation, YOLO data format conversion, YOLO process modification"
UE4 通过与其它Actor互动开门
包拉链不可用,但是是被另一个包。
【树莓派】树莓派调光