Indicators of electronic semiconductor 10000 class clean room
One 、 The standard of 10000 class clean room ( Defined by the number of dust particles and microorganisms ):
1. Allowable number of dust particles ( Per cubic meter ): Greater than or equal to 0.5 The number of particles in microns shall not exceed 350000 individual ; Greater than or equal to 5 The number of particles in microns shall not exceed 2000 individual . You can use DPC-2602 Dust particle counter for movement detection .
2. Allowable number of microorganisms : The number of planktonic bacteria per cubic meter shall not exceed 100 individual ; The number of settling bacteria per Petri dish shall not exceed 3 individual .
Two 、 The main testing standards of 10000 class clean rooms include :
1. Detection of air velocity and its uniformity . This test is the premise of other tests of the effect of the clean room , The purpose of this test is to determine the average airflow flux and its uniformity in the working area of the one-way flow clean room .
2. Air volume detection of system or room .
3. Detection of indoor cleanliness . The detection of cleanliness is to determine the air cleanliness level that can be achieved in a clean environment , Particle counter can be used to detect .
4. Detection of self purification time . By determining the self purification time , Find out the ability to restore the original cleanliness in case of pollution in the clean room .
5. Air flow pattern detection .
6. Noise detection .
7. Illumination detection . The purpose of illuminance detection is to determine the illuminance level and uniformity of the clean room .
8. Vibration detection . The purpose of vibration detection is to identify the vibration amplitude of each indication in the clean room .
9. temperature 、 Humidity detection . temperature 、 The purpose of humidity detection is to change the temperature 、 The ability to adjust humidity to a certain limit . Its content includes detecting the air supply temperature of the dust-free room , Detect the air temperature of representative measuring points , Detect the air temperature at the center of the clean room , Detect the air degree at the sensitive element , Detect the relative temperature of indoor air , Check the return air temperature .
10. Detection of total air volume and fresh air volume .
DPC-online-1A The dust particle counter clean environment online monitoring system is mainly used for real-time monitoring of environmental parameters in the clean room , And complete data storage 、 Management and other functions , The system uses Ethernet communication technology , By the server 、 Router 、 Workstation and various monitoring sensors , It can realize the cleanliness of the clean room 、 Temperature and humidity 、 Differential pressure 、 Real time monitoring of wind speed and other parameters .DPC-online-1A Clean environment online monitoring system can be widely used in clean room monitoring 、 Trend analysis 、 Indoor air quality monitoring (IAQ) etc. .

When testing whether the 10000 grade clean room meets the standard, it is recommended to use the testing instrument of plody measurement and control . As a manufacturer specializing in dust particle counters and other clean room detection instruments , The leading product of plody measurement and control ( Dust particle counter 、 Microenvironment detector, etc ) It has been widely used in Medical Pharmacy 、 Food Hygiene 、 Precision machinery and other fields , It is a trustworthy manufacturer !
边栏推荐
- Openxlsx field reading problem
- Let me teach you how to develop a graphic editor
- 大学生活的自我总结-大一
- Simple use of timeunit
- Matrix and TMB package version issues in R
- Thunderbird tutorial \ easy to use mail client
- I can't stand the common annotations of idea anymore
- repo. conda. An example of COM path error
- Day09 how to create packages import package naming conventions Alibaba Development Manual
- Ue5 hot update - remote server automatic download and version detection (simplehotupdate)
猜你喜欢

Microservice registry Nacos introduction

Logistic regression: the most basic neural network

HDU1232 畅通工程(并查集)

Self summary of college life - freshman

CADD course learning (6) -- obtain the existing virtual compound library (drugbank, zinc)

Detailed explanation of miracast Technology (I): Wi Fi display

MySql——存储引擎

Word import literature -mendeley

Hdu1232 unimpeded project (and collection)

Matrix and TMB package version issues in R
随机推荐
Use go language to read TXT file and write it into Excel
Simple operation with independent keys (hey, a little fancy) (keil5)
Using GEE plug-in in QGIS
MySql——存储引擎
golang定时器使用踩的坑:定时器每天执行一次
Opendrive record
Rename directory in C [closed] - renaming a directory in C [closed]
GPIO circuit principle of stm32
Differences between pycharm and idle and process -- join() in vs Code
How to deal with excessive memory occupation of idea and Google browser
CADD课程学习(5)-- 构建靶点已知的化合结构(ChemDraw)
Hdu1231 maximum continuous subsequence (divide and conquer or dynamic gauge or double pointer)
Numpy——1.数组的创建
Deepin get file (folder) list
cygwin
2022 PMP project management examination agile knowledge points (7)
Oracle triggers and packages
Apple animation optimization
Day09 how to create packages import package naming conventions Alibaba Development Manual
Apple system optimization