ANSI -NEMA-MW-1000-2020 Magnetic iron wire standard
Range
This publication is intended to be concise 、 Introduce all existing magnetic steel wires in a convenient form NEMA standard . It contains circles used in electrical equipment 、 Rectangular and square film insulation and / Or fiber coated copper and aluminum magnet wires . Including the definition of electromagnetic wire commonly used in the coil winding of electrical equipment 、 model 、 Size 、 structure 、 Performance and test methods . Unless otherwise stated , Otherwise, the revision of the product specification in this standard publication will not affect the compliance of the products manufactured during the period when the previous version of the specification came into force .
Scope
This publication is designed to present in concise and convenient form all existing NEMA Standards for magnet wire. It contains Standards for round, rectangular, and square film-insulated and/or fibrouscovered copper and aluminum magnet wire for use in electrical apparatus. Included are the definitions, type designations, dimensions, constructions, performance, and test methods for magnet wire generally used in the winding of coils for electrical apparatus. Unless otherwise stated, a revision to a product specification in this Standards publication does not affect compliance of product manufactured during the time a previous version of that specification was in effect.
Test Procedures
(See Part 1, clause 1.3, for Definitions; clause 1.6 for Test Conditions and Parameters)
3.1 Safety Statement
It is not the intent of this Standard to address all of the safety issues associated with its use. It is
the responsibility of the user of this Standard to train personnel; establish proper health and safety
procedures; and be aware of local, state, and national regulatory restrictions that may apply.
chemical hazard: some tests use materials that local, state, and national regulatory agencies have
determined to be hazardous. These tests shall be performed under controlled conditions that allow for
proper safety and protection of personnel. Information and instructions contained in Safety Data Sheets
(SDS) for handling, working, and disposal of hazardous chemicals shall be followed. Furthermore,
discharges of these chemicals to the environment (the air, water, or ground) must comply with the latest
applicable regulations.
electrical hazard: certain test procedures require high voltage. It is important that the equipment be
designed to comply with good engineering practices—with safety being an integral part of the design.
To avoid electric shocks in such cases, necessary precautions must be taken and test equipment
manufacturers’ recommendations shall be followed.
mechanical hazard: some tests utilizing mechanical equipment may expose the operator to mechanical
hazards. Care must be exercised to protect eyes, fingers, hands, and other body parts from injury.
thermal hazard: in tests requiring elevated temperatures, precautions must be taken in handling
materials exposed to heat to avoid skin burns.
边栏推荐
- 液压旋转接头的使用事项
- 5、離散控制與連續控制
- qt-使用自带的应用框架建立--hello world--使用min GW 32bit
- Leetcode notes No.7
- Basic implementation of pie chart
- NPDP在国内有认可度吗?看一看就明白了!
- 2022 tea master (intermediate) examination questions and tea master (intermediate) examination skills
- Anaconda3 download address Tsinghua University open source software mirror station
- break algorithm---刷题map
- Common operations of numpy on two-dimensional array
猜你喜欢
Basic implementation of pie chart
从Starfish OS持续对SFO的通缩消耗,长远看SFO的价值
Talk about smart Park
2、TD+Learning
Guojingxin center "APEC investment +": some things about the Internet sector today | observation on stabilizing strategic industrial funds
Redis cluster
2、TD+Learning
[loss function] entropy / relative entropy / cross entropy
如何让导电滑环信号更好
Led serial communication
随机推荐
2022 safety officer-c certificate examination paper and safety officer-c certificate simulated examination question bank
从Starfish OS持续对SFO的通缩消耗,长远看SFO的价值
The Ministry of housing and urban rural development officially issued the technical standard for urban information model (CIM) basic platform, which will be implemented from June 1
Matlab code on error analysis (MAE, MAPE, RMSE)
LaTeX 中 xcolor 颜色的用法
2021-03-14 - play with generics
滑环使用如何固定
项目经理有必要考NPDP吗?我告诉你答案
common commands
写一个纯手写的qt的hello world
Working principle of stm32gpio port
Problems of font legend and time scale display of MATLAB drawing coordinate axis
Measure the voltage with analog input (taking Arduino as an example, the range is about 1KV)
从cmath文件看名字是怎样被添加到命名空间std中的
Basic implementation of pie chart
小金额炒股,在手机上开户安全吗?
Multi purpose signal modulation generation system based on environmental optical signal detection and user-defined signal rules
Call (import) in Jupiter notebook ipynb . Py file
regular expression
About how USRP sets the sampling frequency below the minimum sampling frequency reached by the hardware