Influence of oscilloscope probe on signal source impedance
2022-07-05 20:56:00 【PRBTEK】
According to the relative value of impedance , Adding probes and oscilloscopes to the test points leads to various load effects .
The value of signal source impedance may significantly affect the net effect of probe load . for example , When the impedance of the signal source is low , It is difficult to notice the typical high impedance 10X Load effect of probe . This is because the high impedance added in parallel with the low impedance will not significantly change the total impedance
4.1. At the test point (TP) The signal measured on the can be expressed by the signal source and the related load impedance (a). Probe and oscilloscope impedance are added to the signal source load at the detection test point , Cause the measuring system to absorb part of the current (b)
4.2. The higher the impedance of the signal source , The greater the load caused by detection . under these circumstances , All impedances are equal , The detection results in a decrease in the signal amplitude at the test point 30% above
however , At higher signal source impedance , The situation has changed significantly . For equal Z value , When the probe and oscilloscope are not connected to the test point , The load of signal source is 2Z( See chart 4.2a). This results in 0.5ES Signal amplitude . however , When connecting the probe and oscilloscope ( chart 4.2b), The total load on the signal source becomes 1.5Z, The signal amplitude at the test point is reduced to the undetected value 2/3.
In the latter case , There are two ways , Reduce the impact of detection on impedance load . One way is to use a probe with higher impedance . Another method is to detect signals elsewhere in the circuit at the test point with low impedance . for example , The cathode 、 The impedance of transmitter and signal source is usually lower than that of metal disk 、 Collector or drain wire .
The above is the influence of oscilloscope probe on source impedance , If you have other problems in use , Welcome to Xi'an puke Electronic Technology
边栏推荐
- 示波器探头对测量带宽的影响
- Abnova丨 CD81单克隆抗体相关参数和应用
- Write an interface based on flask
- Comparison table of foreign lead American abbreviations
- Duchefa丨低熔点琼脂糖 PPC中英文说明书
- Careercup its 1.8 serial shift includes problems
- Duchefa细胞分裂素丨二氢玉米素 (DHZ)说明书
- 显示器要申请BS 476-7 怎么送样?跟显示屏一样吗??
- Abbkine丨TraKine F-actin染色试剂盒(绿色荧光)方案
- 显示屏DIN 4102-1 Class B1防火测试要求
猜你喜欢
研學旅遊實踐教育的開展助力文旅產業發展
Duchefa丨P1001植物琼脂中英文说明书
Norgen AAV提取剂盒说明书(含特色)
Abbkine trakine F-actin Staining Kit (green fluorescence) scheme
教你自己训练的pytorch模型转caffe(一)
教你自己训练的pytorch模型转caffe(三)
PHP反序列化+MD5碰撞
从架构上详解技术(SLB,Redis,Mysql,Kafka,Clickhouse)的各类热点问题
Typhoon is coming! How to prevent typhoons on construction sites!
基于flask写一个接口
随机推荐
MySQL InnoDB架构原理
Write an interface based on flask
木板ISO 5660-1 热量释放速率摸底测试
Is it necessary for bazel to learn
Abnova maxpab mouse derived polyclonal antibody solution
实现浏览页面时校验用户是否已经完成登录的功能
Popular science | does poor English affect the NPDP exam?
Duchefa cytokinin dihydrozeatin (DHZ) instructions
LeetCode: Distinct Subsequences [115]
Material Design组件 - 使用BottomSheet展现扩展内容(二)
Abnova cyclosporin a monoclonal antibody and its research tools
Web Service简单入门示例
sql系列(基础)-第二章 限制和排序数据
线程池的使用
水泥胶黏剂BS 476-4 不燃性测试
Is it safe to open a stock account by mobile phone? My home is relatively remote. Is there a better way to open an account?
ViewRootImpl和WindowManagerService笔记
Abnova e (diii) (WNV) recombinant protein Chinese and English instructions
Hdu2377bus pass (build more complex diagram +spfa)
国外LEAD美国简称对照表