当前位置:网站首页>Zhuhai laboratory ventilation system construction and installation instructions
Zhuhai laboratory ventilation system construction and installation instructions
2022-07-06 00:47:00 【Design and construction of SiGe Laboratory】
Zhuhai laboratory ventilation system , How is the air conditioner electromechanical installed ?SICOLAB The editor combines the actual ventilation knowledge , This article describes the installation of ventilation system
One 、 Laboratory ventilation system : Analysis of electromechanical installation of air conditioner
1. Install the electromechanical air duct
Before installing the air duct electromechanical system , Check the elevation of air duct and air supply and exhaust outlet , Check whether the positions of civil embedded parts and holes are consistent with those specified , Check the equipment foundation 、 Location of the fan 、 Whether the size meets the requirements , And make a good record of the basic work , And the prefabricated air duct 、 Hangers, etc. are transported to the site , Prepare auxiliary padding for construction 、 Necessary installation tools and materials . Next, install supports and hangers , The form of supports and hangers should be selected according to the specific situation of the project and the size of the air duct section , It must be consistent with the design drawings , The elevation of the installed air duct , Calculate the rectangular air duct from the bottom of the pipe , Calculate the circular duct from the center , Pay attention when installing the bracket , Rectangular insulated air duct cannot be directly connected with the support , Large and strong insulation should be placed under , And the thickness of the insulation layer should be consistent . The hanger should be installed according to the position where the suspender is laid out of the center line of the air duct , SiGe construction believes that the riser snap ring should be installed on the center line of the air duct , Install the center line of the air duct and the bracket steel of the double suspender symmetrically . However, the hanger cannot be directly hung on the flange , Because the snap ring should be installed on the opposite pipe snap ring after the center point of the snap ring semi-circular arc is scribed , According to the thickness of the buried wall and the position of the air duct , Fix the snap ring of the uppermost part , Fire dampers are in all air conditioning systems , All of them have separate smoke exhaust valves , Avoid fire , Valve deformation has an impact on performance .
Two 、 Laboratory ventilation system : Install the valve components
Install the fire damper according to the requirements of the design drawing , It should be ensured that there is a certain flexibility in the adjustment of the valve disc , Locate exactly , It should be in the direction of gas flow to prevent melting , The minimum distance between the wall and the executive structure should be controlled within 100 Mm or so ; After installing the smoke exhaust outlet , Action test is required , Ensure that both electric and manual operations are flexible . The silencer must be installed correctly , And set the hanging Cato separately , Each set should be higher than two ; Various air return outlets 、 The installation of diffuser and louver and air duct should be firm 、 Tight connection , The air outlet and decorative surface should be closely pasted together , There should not be too obvious cracks in it , When installing multiple air vents , It should be ensured that the installation is consistent , And consider the overall coordination .
3、 ... and 、 Laboratory ventilation system : Install the air outlet
1. Installation of pipe type air distribution outlet
The pipe type air distributor is the air collector 、 Air supply duct 、 Air valve 、 Plenum 、 Air distribution device with the functions of thermal insulation materials and so on . According to site conditions , Wire rope suspension system can be provided 、H Type a slide rail suspension system 、T Type slide rail suspension system and other installation forms to meet the requirements . Pipe type air distribution outlet is suitable for tobacco warehouse 、 Cold chain logistics 、 Mechanical workshop 、 Public venues 、 Shopping malls and supermarkets 、 Food workshop 、 Large air volume such as medicine warehouse 、 Large space place .
边栏推荐
- Uniapp development, packaged as H5 and deployed to the server
- Yolov5, pychar, Anaconda environment installation
- FFmpeg抓取RTSP图像进行图像分析
- 详细页返回列表保留原来滚动条所在位置
- State mode design procedure: Heroes in the game can rest, defend, attack normally and attack skills according to different physical strength values.
- notepad++正则表达式替换字符串
- 如何制作自己的机器人
- Comment faire votre propre robot
- KDD 2022 | 脑电AI助力癫痫疾病诊断
- devkit入门
猜你喜欢
随机推荐
Cannot resolve symbol error
cf:D. Insert a Progression【关于数组中的插入 + 绝对值的性质 + 贪心一头一尾最值】
curlpost-php
孤勇者
几百行代码实现一个 JSON 解析器
Free chat robot API
Room cannot create an SQLite connection to verify the queries
Promise
Data analysis thinking analysis methods and business knowledge - analysis methods (III)
小程序技术优势与产业互联网相结合的分析
Spark AQE
如何利用Flutter框架开发运行小程序
DD's command
Pointer - character pointer
cf:H. Maximal AND【位运算练习 + k次操作 + 最大And】
Kotlin core programming - algebraic data types and pattern matching (3)
《编程之美》读书笔记
How to make your own robot
95后CV工程师晒出工资单,狠补了这个,真香...
Spark-SQL UDF函数